Managed switch with twenty four 10/100base-tx poe ports plus two mini gbic slots for 1000base-sx or lx fiber connectivity or 10/100/1000base-tx copper connectivity (137 pages)
Managed switch with eight 10/100/1000base-tx ports plus one mini gbic slot for 1000base-sx or lx fiber or one 10/100/1000base-tx port eight poe ports (108 pages)
17.25” W x 10” D x 1.75” H (440mm x 254mm x 44mm) Weight: Switch Chassis: 6.12 lbs (2.8 kg) Copper Module: 0.41 lbs (18.4 kg) Fiber Module: 0.59 lbs (.27 kg) GIG Module: 0.11 lbs (.05 kg) WARRANTY: Limited Lifetime ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 2...
There is sufficient space surrounding the switch to allow for proper ventilation (the switch may not function according to specifications beyond the temperature range of 0 to 50 degrees C). ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 3...
Push the module firmly to ensure connection with the module and the connector in the switch. Tighten the screws to firmly connect the module to the switch. Power ON the switch. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 4...
Note: Since dual-speed ports are auto-sensing for both 10 and 100Mbps, it is recommended that high quality CAT5E or better cables (which work for both 10Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 5...
If two switches are cascaded together, there could be a bottleneck at the cascading connection. Additional cables could reduce the bottleneck problem. However, additional cables can cause the switch to become unstable because of looping. The trunking function ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 6...
Page 9
11-22-33” to Port 5 will keep this MAC ID alive on Port 5 but will also limit this MAC address to work on Port 5 only or reject it from Port 5. It depends on the port security mode setting. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07...
Page 10
From Console/Telnet when running: Use TFTP protocol with TFTP server for run-time code and configuration backup/update. From Web Browser: Use HTTP protocol for run-time code and configuration backup. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 8...
Stop Bit: 1 e. Flow Control: None 5. Select OK. 6. Power on the switch 7. The login screen will be displayed on your screen once the initialization is complete. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 9...
Page 12
2. Enter the username and password. The default username is admin and the default password is 123456. 3. After logging into the switch, a prompt will be displayed. You can use the help or ? to display a list of commands. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 10...
Page 13
If the ingress port is in the same VLAN of the received packet, this packet will go to forwarding stage. Otherwise, the packet will be discarded by VLAN filtering at ingress port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 11...
Page 14
For most VLAN applications, SVL mode is suggested. admin Set administrator name and password set admin Set age time of the switch set age [time} 0 = disable aging operation; 1~65535; ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 12...
Page 15
– set 802.1x re- authentication timeout period reqcnt – set 802.1x max request count rspi – set radius server address shkey – set 802.1x shared key ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 13...
Page 16
Set name and password for guest gvrp Enable or disable GVRP protocol set gvrp [1|2] <1=enable; 2=disable> http Enable or disable HTTP protocol set http enable [or disable] ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 14...
Page 17
DHCP function is enabled, the switch will try to obtain the IP configuration from the DHCP server. If a DHCP server is not found, the switch will use its default IP configuration. You can ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 15...
Page 18
Port 1, 2 and 3 cannot communicate with each other, but they can communicate with other unprotected ports – e.g. Port 4 ,5 and 6. This function is often used to ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 16...
Page 19
This command is used to set the [0:disable|1:enable] maximum traffic rate to/from Set packets drop for ingress limit connection ports of the switch. set ratecontrol [ingress|egress] ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 17...
Page 20
Please refer to “set arl” command for port 1 to Accept mode for Static static address setting. Or, you can MAC addresses. set static address from the “Dynamic mode 0 = No Security ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 18...
Page 21
>set sta bridge the device with the lowest MAC priority - set bridge priority. address will then become the root hello - set bridge hello time device. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 19...
Page 22
– set broadcast control for : this set stormcontrol rate each port subcommand is used to set the fd – set flooding control for each maximum storm rate that is allowed ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 20...
Page 23
[+/-] [port#] [trunk#] is sub-command to add/remove ports to/ from trunk groups. Only Port 1~8 is available for trunk operation. default This command restores the switch to default ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 21...
Page 24
“abcd” from TFTP server 192.168.1.80 as its configuration setting. exit Use this command to logout. Same as the logout command. logout Use this command to logout. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 22...
Page 25
For applications, you should select Auto Detect mode if the connected device is auto-negotiation enabled. You can select Auto Negotiation mode if the connected device is auto- ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 23...
Page 26
Radius Server Port Number: 1812 Shared Key: 12345678 show dot1x port Displays: Port Status Auth Mode The Auth. Mode could be Auto, FA (Forced Authenticated), FU (Forced Unauthenticated) and No (No 802.1x function). ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 24...
Page 27
Reject is used for the static MAC addresses that cannot be accessed. Displays spanning tree setting show sta stormcontrol Displays current packet storm control show stormcontrol configuration ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 25...
The default username is admin and password 123456. Click on the Login button. The login process now is completed. The management home page will be displayed. Figure 6.1 – Management Home Page ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 26...
If any modifications have been made to the functions listed above, click Apply to activate the new settings. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 27...
Auto detect mode keeps the auto-negotiation function ON, but modifies its attribute if the auto mode of the port is disabled. The Auto-MDIX function will be enabled in this mode. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 28...
Page 31
Auto - Auto-negotiation enable/disable status of ports. Speed - Current operation speed if the ports are up. Duplex - Current duplex mode setting if the ports are up. Flow Control - Current flow control status. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 29...
Figure 6.5 – Spanning Tree Parameters Select a port number from the drop down arrow next to Bridge Port Number to check the spanning tree status. Click on Apply after making any changes. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 31...
MAC addresses are listed. Once the correct MAC addresses are listed, recover the aging time. Figure 6.6 – Dynamic MAC Address Table ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 32...
MAC address. The two modes that can be used are: Accept mode - Only the static address can access the network via the port. Reject mode - Only the static address cannot access network via the port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 33...
Reject function: Only the static address will be rejected by the port, i.e. other MAC addresses (except static MAC addresses) can access the network through the port. Figure 6.8 – MAC Security Configuration ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 34...
Click Apply to save the changes. The bottom section is the Port-based VLAN Table. This table displays the port-based VLANs for the switch. Figure 6.9 – Port-Based VLAN Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 35...
Port VID and priority setting will be applied to the tag. Instructions: Select the port number. Set Port VID and Priority for Tag. Click Apply to activate the settings. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 36...
3. Click Apply to activate the new setting. To delete an 802.1Q VLAN: 1. Select the VLAN under Show Static VLAN Table. 2. Click Delete to delete the 802.1Q VLAN. Tagged/Untagged Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 37...
Page 40
Only users in the same VLAN as the Management Port PVID (configured in “802.1Q VLAN) can manage the switch via Web/Telnet/SNMP. Users in other VLANs will not be able to manage the switch from the network. Figure 6.11 – Static 802.1Q VLAN ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 38...
6. Set the Server Timeout Period. The Server Timeout Period is the timeout period for the request between the switch and RADIUS server. 7. Set the Supplicant Timeout Period. This value is the timeout between the switch and ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 39...
Page 42
Force-Unauthorized -This mode will force the authenticating port to fail in the authentication process and the real authentication result will be ignored. None - This mode will disable 802.1x operation on the specified port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 40...
4. If you want to choose all ports, click on Select All. Remove all can be used at a later time to remove the protection from all of the ports ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 41...
Note: The trunk connection supports the redundant function. If a trunk cable is broken, the traffic going through that cable will be transferred to another trunk cable in the trunk connection automatically. 6.16 – Trunk Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 42...
6. Enter the capture frequency. 7. Click Apply to save the settings. 8. If you want to disable the Mirror function, select Disable and click Apply. 6.17 – Mirror Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 43...
The priority value is 0 ~ 7 for the 802.1P tagged packets. 5. Click Apply to activate the settings. To disable the QoS operation, select Disable and click Apply. 6.18 – QoS Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 44...
If it is enabled, the extra packets will be dropped to limit the ingress traffic rate. If it is disabled, the flow control function will be used to pause the ingress traffic. 6.19 – Ingress/Egress Rate Control ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 45...
Note: Broadcast is “one to all” traffic, so every port will receive packets. Flooding is “one to all” traffic, but caused by the MAC address not being found in the switch. All ports will receive the packets. 6.20 – Storm Control ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 46...
4. Click Apply 5. Enter the following information: • GET/SET Community Name • Trap IP Address and Community Name 6. Click Apply to save the settings. 6.21 – SNMP Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 47...
Use the Refresh button to update the counter immediately. You can reset the counters to zero with the Reset Statistics button. 6.23 – Statistics Screen ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 48...
Etherlike MIB and Private MIB. The default GET community name is public and SET community name is private. The switch supports up to five trap receivers with different trap community names. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 49...
Refer to the description of the Upgrade function in the console operation of this manual. 3. From web browser – Use the web management interface (http protocol). Refer to the description of the Tools function in Section 6.3. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 50...
5. The components involved in the problem 6. Any particular application that, when used, appears to create the problem 7. An accurate list of Waters Network Systems product model(s) involved. Include the date(s) that you purchased the products from your supplier.
(user) charge. Shipping and Packaging Information Should you need to ship the unit back to Waters Network Systems, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
In the event of a malfunction or other indication of product failure attributable directly to faulty materials and/or workmanship, Waters Network Systems will, at its option, repair or replace the defective products or components at no additional charge as set for herein.