hit counter code

Waters Network Systems ProSwitch FlexPort- 2600M Installation Manual And Operating Manual

Managed modular copper and fiber switch
Hide thumbs Also See for ProSwitch FlexPort- 2600M:

Advertisement

Quick Links

2
1
Managed Modular Copper and Fiber Switch
CORPORATE HEADQUARTERS
5001 American Blvd. W., Suite 605
Bloomington, MN 55437
Phone: 800.441.5319
Phone: 952.831.5603

INSTALLATION GUIDE

AND

OPERATING MANUAL

®
ProSwitch
FlexPort- 2600M
MANUFACTURING/CUSTOMER SERVICE
945 37
Rochester, MN 55901
Phone: 800.328.2275
Phone: 507.285.1951
Web site:
http://www.watersnet.com
th
Avenue, NW

Advertisement

Table of Contents
loading

Summary of Contents for Waters Network Systems ProSwitch FlexPort- 2600M

  • Page 1: Installation Guide

    INSTALLATION GUIDE OPERATING MANUAL ® ProSwitch FlexPort- 2600M Managed Modular Copper and Fiber Switch CORPORATE HEADQUARTERS MANUFACTURING/CUSTOMER SERVICE 5001 American Blvd. W., Suite 605 945 37 Avenue, NW Bloomington, MN 55437 Rochester, MN 55901 Phone: 800.441.5319 Phone: 800.328.2275 Phone: 952.831.5603 Phone: 507.285.1951 Web site: http://www.watersnet.com...
  • Page 2: Table Of Contents

    Maintenance Tools ...................49 6.22 Telnet and SNMP .....................49 6.23 Software Update and Backup................50 TROUBLESHOOTING...................51 Before Calling for Assistance ................51 Return Material Authorization (RMA) Procedure..........52 Shipping and Packaging Information ...............52 Warranty......................53 ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 2...
  • Page 3: Specifications

    Software Update: TFTP protocol and Xmodem LED INDICATORS: Power/Link/Activity/HDX/FDX System LED Power NETWORK STANDARDS: IEEE 802.3 IEEE 802.3u IEEE 802.3z IEEE 802.3ab IEEE 802.3x IEEE 802.1P/Q IEEE 802.1D IEEE 802.1x ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 1...
  • Page 4: Waters Network Systems™ Proswitch ® - 2600M, User's Manual, 02/07

    17.25” W x 10” D x 1.75” H (440mm x 254mm x 44mm) Weight: Switch Chassis: 6.12 lbs (2.8 kg) Copper Module: 0.41 lbs (18.4 kg) Fiber Module: 0.59 lbs (.27 kg) GIG Module: 0.11 lbs (.05 kg) WARRANTY: Limited Lifetime ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 2...
  • Page 5: Package Contents - Proswitch ® - 2600M

    There is sufficient space surrounding the switch to allow for proper ventilation (the switch may not function according to specifications beyond the temperature range of 0 to 50 degrees C). ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 3...
  • Page 6: Rack Mounting The Proswitch - 2600M

    Push the module firmly to ensure connection with the module and the connector in the switch. Tighten the screws to firmly connect the module to the switch. Power ON the switch. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 4...
  • Page 7: Connecting The Proswitch ® - 2600M

    Note: Since dual-speed ports are auto-sensing for both 10 and 100Mbps, it is recommended that high quality CAT5E or better cables (which work for both 10Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 5...
  • Page 8: Status Of Leds

    If two switches are cascaded together, there could be a bottleneck at the cascading connection. Additional cables could reduce the bottleneck problem. However, additional cables can cause the switch to become unstable because of looping. The trunking function ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 6...
  • Page 9 11-22-33” to Port 5 will keep this MAC ID alive on Port 5 but will also limit this MAC address to work on Port 5 only or reject it from Port 5. It depends on the port security mode setting. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07...
  • Page 10 From Console/Telnet when running: Use TFTP protocol with TFTP server for run-time code and configuration backup/update. From Web Browser: Use HTTP protocol for run-time code and configuration backup. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 8...
  • Page 11: Console Management Interface (Cmi)

    Stop Bit: 1 e. Flow Control: None 5. Select OK. 6. Power on the switch 7. The login screen will be displayed on your screen once the initialization is complete. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 9...
  • Page 12 2. Enter the username and password. The default username is admin and the default password is 123456. 3. After logging into the switch, a prompt will be displayed. You can use the help or ? to display a list of commands. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 10...
  • Page 13 If the ingress port is in the same VLAN of the received packet, this packet will go to forwarding stage. Otherwise, the packet will be discarded by VLAN filtering at ingress port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 11...
  • Page 14 For most VLAN applications, SVL mode is suggested. admin Set administrator name and password set admin Set age time of the switch set age [time} 0 = disable aging operation; 1~65535; ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 12...
  • Page 15 – set 802.1x re- authentication timeout period reqcnt – set 802.1x max request count rspi – set radius server address shkey – set 802.1x shared key ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 13...
  • Page 16 Set name and password for guest gvrp Enable or disable GVRP protocol set gvrp [1|2] <1=enable; 2=disable> http Enable or disable HTTP protocol set http enable [or disable] ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 14...
  • Page 17 DHCP function is enabled, the switch will try to obtain the IP configuration from the DHCP server. If a DHCP server is not found, the switch will use its default IP configuration. You can ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 15...
  • Page 18 Port 1, 2 and 3 cannot communicate with each other, but they can communicate with other unprotected ports – e.g. Port 4 ,5 and 6. This function is often used to ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 16...
  • Page 19 This command is used to set the [0:disable|1:enable] maximum traffic rate to/from Set packets drop for ingress limit connection ports of the switch. set ratecontrol [ingress|egress] ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 17...
  • Page 20 Please refer to “set arl” command for port 1 to Accept mode for Static static address setting. Or, you can MAC addresses. set static address from the “Dynamic mode 0 = No Security ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 18...
  • Page 21 >set sta bridge the device with the lowest MAC priority - set bridge priority. address will then become the root hello - set bridge hello time device. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 19...
  • Page 22 – set broadcast control for : this set stormcontrol rate each port subcommand is used to set the fd – set flooding control for each maximum storm rate that is allowed ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 20...
  • Page 23 [+/-] [port#] [trunk#] is sub-command to add/remove ports to/ from trunk groups. Only Port 1~8 is available for trunk operation. default This command restores the switch to default ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 21...
  • Page 24 “abcd” from TFTP server 192.168.1.80 as its configuration setting. exit Use this command to logout. Same as the logout command. logout Use this command to logout. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 22...
  • Page 25 For applications, you should select Auto Detect mode if the connected device is auto-negotiation enabled. You can select Auto Negotiation mode if the connected device is auto- ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 23...
  • Page 26 Radius Server Port Number: 1812 Shared Key: 12345678 show dot1x port Displays: Port Status Auth Mode The Auth. Mode could be Auto, FA (Forced Authenticated), FU (Forced Unauthenticated) and No (No 802.1x function). ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 24...
  • Page 27 Reject is used for the static MAC addresses that cannot be accessed. Displays spanning tree setting show sta stormcontrol Displays current packet storm control show stormcontrol configuration ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 25...
  • Page 28: Web Management

    The default username is admin and password 123456. Click on the Login button. The login process now is completed. The management home page will be displayed. Figure 6.1 – Management Home Page ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 26...
  • Page 29: System Configuration Page

    If any modifications have been made to the functions listed above, click Apply to activate the new settings. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 27...
  • Page 30: Port Configuration

    Auto detect mode keeps the auto-negotiation function ON, but modifies its attribute if the auto mode of the port is disabled. The Auto-MDIX function will be enabled in this mode. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 28...
  • Page 31 Auto - Auto-negotiation enable/disable status of ports. Speed - Current operation speed if the ports are up. Duplex - Current duplex mode setting if the ports are up. Flow Control - Current flow control status. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 29...
  • Page 32 Figure 6.3 – Port Configuration ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 30...
  • Page 33: Spanning Tree

    Figure 6.5 – Spanning Tree Parameters Select a port number from the drop down arrow next to Bridge Port Number to check the spanning tree status. Click on Apply after making any changes. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 31...
  • Page 34: Dynamic Mac Address Table

    MAC addresses are listed. Once the correct MAC addresses are listed, recover the aging time. Figure 6.6 – Dynamic MAC Address Table ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 32...
  • Page 35: Static Mac Address Table

    MAC address. The two modes that can be used are: Accept mode - Only the static address can access the network via the port. Reject mode - Only the static address cannot access network via the port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 33...
  • Page 36: Mac Security Configuration

    Reject function: Only the static address will be rejected by the port, i.e. other MAC addresses (except static MAC addresses) can access the network through the port. Figure 6.8 – MAC Security Configuration ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 34...
  • Page 37: Port-Based Vlans

    Click Apply to save the changes. The bottom section is the Port-based VLAN Table. This table displays the port-based VLANs for the switch. Figure 6.9 – Port-Based VLAN Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 35...
  • Page 38: 802.1Q Vlan Configuration

    Port VID and priority setting will be applied to the tag. Instructions: Select the port number. Set Port VID and Priority for Tag. Click Apply to activate the settings. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 36...
  • Page 39: Static 802.1Q Vlan

    3. Click Apply to activate the new setting. To delete an 802.1Q VLAN: 1. Select the VLAN under Show Static VLAN Table. 2. Click Delete to delete the 802.1Q VLAN. Tagged/Untagged Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 37...
  • Page 40 Only users in the same VLAN as the Management Port PVID (configured in “802.1Q VLAN) can manage the switch via Web/Telnet/SNMP. Users in other VLANs will not be able to manage the switch from the network. Figure 6.11 – Static 802.1Q VLAN ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 38...
  • Page 41: 802.1Q Vlan Table

    6. Set the Server Timeout Period. The Server Timeout Period is the timeout period for the request between the switch and RADIUS server. 7. Set the Supplicant Timeout Period. This value is the timeout between the switch and ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 39...
  • Page 42 Force-Unauthorized -This mode will force the authenticating port to fail in the authentication process and the real authentication result will be ignored. None - This mode will disable 802.1x operation on the specified port. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 40...
  • Page 43: Protected Port Configuration

    4. If you want to choose all ports, click on Select All. Remove all can be used at a later time to remove the protection from all of the ports ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 41...
  • Page 44: Trunking

    Note: The trunk connection supports the redundant function. If a trunk cable is broken, the traffic going through that cable will be transferred to another trunk cable in the trunk connection automatically. 6.16 – Trunk Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 42...
  • Page 45: Mirror Settings

    6. Enter the capture frequency. 7. Click Apply to save the settings. 8. If you want to disable the Mirror function, select Disable and click Apply. 6.17 – Mirror Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 43...
  • Page 46: Qos Settings

    The priority value is 0 ~ 7 for the 802.1P tagged packets. 5. Click Apply to activate the settings. To disable the QoS operation, select Disable and click Apply. 6.18 – QoS Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 44...
  • Page 47: Ingress/Egress Rate Control

    If it is enabled, the extra packets will be dropped to limit the ingress traffic rate. If it is disabled, the flow control function will be used to pause the ingress traffic. 6.19 – Ingress/Egress Rate Control ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 45...
  • Page 48: Storm Control

    Note: Broadcast is “one to all” traffic, so every port will receive packets. Flooding is “one to all” traffic, but caused by the MAC address not being found in the switch. All ports will receive the packets. 6.20 – Storm Control ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 46...
  • Page 49: Snmp

    4. Click Apply 5. Enter the following information: • GET/SET Community Name • Trap IP Address and Community Name 6. Click Apply to save the settings. 6.21 – SNMP Settings ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 47...
  • Page 50: Igmp

    Use the Refresh button to update the counter immediately. You can reset the counters to zero with the Reset Statistics button. 6.23 – Statistics Screen ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 48...
  • Page 51: Maintenance Tools

    Etherlike MIB and Private MIB. The default GET community name is public and SET community name is private. The switch supports up to five trap receivers with different trap community names. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 49...
  • Page 52: Software Update And Backup

    Refer to the description of the Upgrade function in the console operation of this manual. 3. From web browser – Use the web management interface (http protocol). Refer to the description of the Tools function in Section 6.3. ® WATERS NETWORK SYSTEMS™ ProSwitch 2600M, User’s Manual, 02/07 Page 50...
  • Page 53: Troubleshooting

    5. The components involved in the problem 6. Any particular application that, when used, appears to create the problem 7. An accurate list of Waters Network Systems product model(s) involved. Include the date(s) that you purchased the products from your supplier.
  • Page 54: Return Material Authorization (Rma) Procedure

    (user) charge. Shipping and Packaging Information Should you need to ship the unit back to Waters Network Systems, please follow these instructions: Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection.
  • Page 55: Warranty

    In the event of a malfunction or other indication of product failure attributable directly to faulty materials and/or workmanship, Waters Network Systems will, at its option, repair or replace the defective products or components at no additional charge as set for herein.

Table of Contents