COPIER (Service mode for printer) > ADJUST (Adjustment mode) > DENS
HLMT-PTY
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
HLMT-PTM
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
HLMT-PTC
2
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Related Service Mode
Amount of Change per
Unit
Adj Y-clr toner dens tgt VL upper limit
To adjust the upper limit of the toner density target value of the Toner Density Sensor (Y).
As the value is incremented by 1, the upper limit is increased by 0.5%.
Increase the value when a density failure/coarseness occurs, and decrease the value when
fogging/scattering occurs.
In principle, the value should be the same as that of LLMT-PTY.
When an image failure (density failure, coarseness, fogging, carrier adherence, scattering, etc.)
occurs
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Take necessary action in accordance with the instructions from the Quality Support Division.
-4 to 4
%
0
COPIER> ADJUST> DENS> LLMT-PTY
0.5
Adj M-clr toner dens tgt VL upper limit
To adjust the upper limit of the toner density target value of the Toner Density Sensor (M).
As the value is incremented by 1, the upper limit is increased by 0.5%.
Increase the value when a density failure/coarseness occurs, and decrease the value when
fogging/scattering occurs.
In principle, the value should be the same as that of LLMT-PTM.
When an image failure (density failure, coarseness, fogging, carrier adherence, scattering, etc.)
occurs
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Take necessary action in accordance with the instructions from the Quality Support Division.
-4 to 4
%
0
COPIER> ADJUST> DENS> LLMT-PTM
0.5
Adj C-clr toner dens tgt VL upper limit
To adjust the upper limit of the toner density target value of the Toner Density Sensor (C).
As the value is incremented by 1, the upper limit is increased by 0.5%.
Increase the value when a density failure/coarseness occurs, and decrease the value when
fogging/scattering occurs.
In principle, the value should be the same as that of LLMT-PTC.
When an image failure (density failure, coarseness, fogging, carrier adherence, scattering, etc.)
occurs
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Take necessary action in accordance with the instructions from the Quality Support Division.
-4 to 4
%
0
COPIER> ADJUST> DENS> LLMT-PTC
0.5
819