hit counter code

Laser Control Circuit - Canon LBP-1260 Service Manual

Table of Contents

Advertisement

CHAPTER 2
control circuit
i
This circuit switches the laser diode (LD]
ON and OFF at a constant intensity In
response to the /VDO signal from the video
controller. The /VDO signal. sent from the
video controller to the DC controller, goes
to the switching circuit in the laser driver
circuit as It Is as the /VDATA signal
The microprocessor (CPU:IC201]
outputs the INTENSITY CONTROL signals
to the analog adder circuit according to the
internal data. The APCOR and APCOS
signals are added to this circuit at a ratio
of approximately 8 to 1. and then sent to
the laser current setting circuit located in
the laser driver as the AUTOMATIC
POWER CONTROL OUTPUT signal
DC controller
2-12
The CPU adjusts the value of the
APCOUT signal by changing the APCOR
signal for coarse adjustment, and the
APCOS sIgnal for fine adjustment.
The output current of the laser current
setting circuit is sent to the switching
circuit and the laser diode is switched ON
and OFF in response to the /VDATA signal
when the VIDEO DATA ENABLE signal
Laser
driver
Laser driver IC