Disassembly/Assembly > Pickup/Feed System > Removing the Delivery/Reverse Unit > Procedure
6) Assemble the Registration/Pickup Unit, output a test print, and confirm that images with
uneven density (white spots) are not generated.
7) End if images with uneven density (white spots) are not generated.
Adjust again the Registration/Pickup Unit if images with uneven density (white spots) are
generated.
4
Disassembly/Assembly > Pickup/Feed System > Removing the Delivery/Reverse Unit > Procedure
Removing the Delivery/Reverse Unit
■ Preparation
1) Remove the Fixing Assembly(Refer to page 4-137).
■ Procedure
F-4-440
1) Remove the Delivery/Reverse Unit [1].
• 4 Screws [2]
F-4-441
[1]
4x
[2]
4-166
F-4-442
4-166