hit counter code

ACC RC-850 Reference Manual page 34

Repeater controller
Table of Contents

Advertisement

Control Operator's Reference Manual
Purpose
....,;
These commands select the mode of operation of the reverse patch and phone
.
line control.
Remarks
Mode 0 causes the controller to auto-answer the phone and requires the Reverse
Patch User level command to activate the reverse patch.
Mode 1 causes the controller to auto-answer, and
if
a valid command is not
received within five seconds, automatically initiates a general reverse patch
ringout.
Mode 2 causes the controller to automatically ring out when the phone rings
without answering the phone unless a user answers the reverse patch.
The "Don't Answer Next Time" command instructs the controller not to answer
the phone the next time
it
rings. This permits an auto-answer modem sharing
the same phone line to answer and allow remote computer access to the
controller. The "don't answer" request
will
time out in two minutes - after two
minutes, the controller will again answer the phone normally .
.&
WARNING
One or more Reverse Patch modes may not be legal in the Amateur Service.
User Loadable Autodialer Unlock / Lock
User Loadable Autodialer Bank
0
Unlock
User Loadable Autodialer Bank
0
Lock
User Loadable Autodialer Bank
1
Unlock
User Loadable Autodialer Bank
1
Lock
User Loadable Autodialer Bank
2
Unlock
User Loadable Autodialer Bank 2 Lock
Purpose
These commands permit or prevent changes to telephone numbers stored in the
User Loadable Autodialer.
Remarks
Telephone numbers in the User Loadable Autodialer may be loaded and erased by
repeater users or by any class of user given the Load/Erase command codes. The
Autodialer banks can be locked to prevent modification to the numbers stored.
Each bank of numbers can be locked independently.
(Access and Command Modes)
2- 22