Important Safety Information You MUST read these warnings carefully before installing or using the hob. If you need assistance, contact our Customer Care Department on 08705 950 950 Installation Perishable food, plastic items and areosols may be This appliance must be installed and serviced by a affected by heat and should not be stored above or competent person as stated in the Gas Safety below the hob unit.
Contents For the Installer For the User Instructions for the Installer Important Safety Information Description of the Hob Important safety requirements Operation Installation Maintenance and Cleaning Building In Something Not Working? Electrical connections Guarantee Conditions Wiring Diagram Fault Finding Guide to Use the instructions Commissioning Conversion from Natural Gas to LPG The following symbols will be found in the text to guide...
Operation Hob burners To light a burner: turn the relevant control knob anticlockwise to the maximum position, then push it down to ignite the burner; upon ignition, keep the knob pushed down about 5 seconds. This will allow the "thermocouple" (Fig. 1, D) to be heated and the safety device to be switched off, otherwise the gas supply would be interrupted.
Maintenance and Cleaning Before any maintenance or cleaning can be carried out, you must DISCONNECT the hob from the electricity supply. The hob is best cleaned whilst it is still warm, as spillage can be removed more easily than if it is left to cool.
Cast Iron Pan Supports The hob has cast iron pan supports. Take care when removing them. They are very heavy and could damage the hob or your kitchen furniture if you let them fall down. To keep the pan supports in the correct position, they are hooked into hinges at the back of the hob.
Service and Spare Parts Customer Care Department For general enquiries concerning your Electrolux appli- ance or for further information on Electrolux products, please contact our Customer Care Department by letter In the event of your appliance requiring service, or if you or telephone at the address below or visit our website at wish to purchase spare parts, please contact your local www.electrolux.co.uk...
Instructions for the Installer Ignition HT Spark Engineers technical data Spark Generator Ispra Control's BF 50066 OVERALL DIMENSIONS 220- 240V 0.6 VA T 120 Spark Gap Fixed Width: 680 mm Depth: 510 mm Rear Left Burner (semi rapid) Heat Input 2.0 kW (6824 BTU/HR) CUT OUT DIMENSIONS Front Left Burner (auxiliary)
Important safety requirements This hob must be installed in accordance with the Gas FITTING THE GAS HOB Safety (Installation and Use) Regulations (Current Edition) WITHOUT A COOKER HOOD ABOVE and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I.S.
Installation IMPORTANT: This hob must be installed by a competent person to the relevant Gas Standards. Any gas installation must be carried out by a competent person. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.
Building In Building over a cupboard or Building over a kitchen unit with drawer door If the hob is to be installed above a cupboard or drawer it Proper arrangements must be taken in designing the will be necessary to fit a heat resistant board below the furniture unit, in order to avoid any contact with the bottom base of the hob on the underside of the work surface.
Seal FO 0199 Electrical connections Any electrical work required to install this hob Permanent Connection should be carried out by a qualified electrician or In the case of a permanent connection, it is necessary competent person, in accordance with the current that you install a double pole switch between the hob regulations.
Wiring Diagram A. IGNITOR SWITCH B. IGNITOR UNIT 220/240 Fault Finding Preliminary Electrical Systems PLUG (with cover SOCKET Check removed) (face view) Earth Wire Brown Blue Green/Yellow START Isolate appliance Neutral Wire and carry out: Blue A: Earth Continuity check. Blue Green Brown...
Page 14
Ignition System / Gas Ignition Check gas supply at Ignitor does not spark burner Check plug top fuse Light burner manually replace if necessary Check polarity and Check by pass simmer earth continuity of adjusted supply point Check position of the Check earth continuity electrode of appliance...
Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. Turn the gas tap to the MAX position and ignite. Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times.