hit counter code
Paradox PCS265 LTE Installation And Programming Guide

Paradox PCS265 LTE Installation And Programming Guide

Also See for PCS265 LTE:

Advertisement

Paradox PCS265 LTE Installation And Programming Guide

Installation

Installation

  1. Mounting hole
  2. Antenna connector
  3. Wall tamper hole
  4. Serial connector
  5. RS485 / power terminal
  6. Upgrade connector
  7. Battery terminal
  8. Cover tamper switch

SIM Card Connection

The PCS265 LTE supports two nano LTE/4G/3G/2G or GSM provider SIM cards. To install the SIM cards, open the SIM Card tray and insert card into base, as shown. SIM Card 1 is used as "Primary" and SIM Card 2 for "Backup".
SIM Card Connection

Note: SIM Card 2 can only be configured via SMS.

Panel Connections

Connect the PCS265 LTE's serial out to the serial connector on the panel.

  • For LTE/4G/3G/2G reporting, connect to the Serial port of the panel.
  • For GSM reporting, connect to the EBUS port of the panel.
    Panel Connections

RS485 Connection

A CVT485 module can be connected onto the control panel's EBUS in order to lengthen the distance (up to 300 m. / 1000 ft.) between the panel and the PCS265 LTE. Refer to the drawing for connections.
RS485 Connection

External Antenna Connection

Use the ANTK4G LTE external antenna kit for PTCRB installations or to improve RF reception if your module's signal strength is weak.
External antenna kits and extension kits are purchased separately.

IP Module Connection

The PCS265 LTE can be connected to an IP Internet Module's PCS port. For more information on how to configure this option, please refer to the IP module's Installation manual.

Powering-up the Device

Once your hardware connections are completed, the PCS265 LTE module will begin its power up sequence.

  • Power LED will turn solid green
  • Status LED will be red and switch to green after approximately 10 seconds
  • SIM card 1LED will slowly flash orange while searching for the GSM network; once found the LED will be solid orange

If configured for LTE/4G/3G/2G reporting, you will need to configure network provider information. Refer to the Programming section.

Note: The battery is optional. If a battery is used/installed, do not allow the battery to deplete and ensure that the battery is replaced when low.

The battery function is to support power shut down and not to be used as backup as defined in EN50131-6.

LED Functionality

LED Functionality
SIM1 and SIM2* Slow orange flashing - Searching the network
Solid purple - LTE/4G
Solid blue - 3G
Solid orange - GSM
Solid green - 2G (n/a for North and South America)
Quick flashing - Exchanging data (the color of the flashing LED corresponds to the color of LTE/4G/3G/2G or GSM depending on which is being used)
Off - SIM card 1 or 2 is not installed, not active, or currently not in use
Power Solid green
Off - No power
Status Red - Error condition, no firmware
Red/Green alternating - updating firmware
Green - No error and/or battery fully charged
Orange - Battery charging
Signal Strength Three LEDs indicate network strength
All LEDs
(except power)
Flashing - No data communication

*When using an e-bus connection, the LED is always orange.

Programming

In order to configure the PCS265 LTE for reporting, you will need to first configure your SIM cards. Please note that SIM Card 1 can be configured via panel programming and SIM Card 2 via SMS.

LTE/4G/3G/2G Reporting

(Serial Port or via SMS Connection ONLY)

Network Provider Information

MG/SP EVO Feature
[921] [2960] APN part 1 (characters 1-16)
[922] [2961] APN part 2 (characters 17-32)
[923] [2962] APN user name part 1 (1-16)
[924] [2963] APN user name part 2 (17-32)
[925] [2964] APN password part 1 (1-16)
[926] [2965] APN password part 2 (17-32)

This information can be obtained from your mobile network provider.

Network Provider Information
Refer to the List of SMS Commands Table.

LTE/4G/3G/2G Reporting Options

MG/SP EVO Feature Details
[918]
[919]
[2976] to [2983] Account / Partition Registration MG/SP: Sections represent account/ partition 1 and 2
EVO: Sections represent account / partition 1 to 8
[806] [2975] [7] Off + [8] Off = landline only
[7] Off + [8] On = LTE/4G/3G/2G primary / landline backup (default)
[7] On + [8] Off = landline only
[7] On + [8] On = landline and LTE/4G/3G/2G in parallel
Receiver Settings MG/SP
Receiver #: 1 2 Backup
IP address* [929] [936] [943]
IP port ** [930] [937] [944]
IP address WAN 2 [931] [938] [945]
IP port WAN2 [932] [939] [946]
Receiver password [933] [940] [947]
Security Profile [934] [941] [948]
Module registration
Press [ARM] to register
[935] [942] [949]
Receiver Settings EVO
Receiver #: 1 2 3 4
IP address*
IP port **
IP address WAN 2 [2984] [2986] [2988] [2990]
IP port WAN2
Receiver password
Security Profile
Module registration
Press [ARM] to register
[2985] [2987] [2989] [2991]
* For 1 or 2 digit numbers, add "0's" before the digit: e.g., 138.002.043.006
** Default = 10000
Enter [MEM] for blank space

GSM Reporting (EBUS Connection)

Reporting Options

MG/SP EVO Details
[805] [2950] [1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM backup (default)
[1] On + [2] Off = GSM primary / landline backup
[1] On + [2] On = GSM only
[815] to
[817]
[3071] to
[3074]
Telephone numbers
[811] to
[812]
[3061] to
[3068]
Account numbers

SMS Messages for Backup

Command Description
P[PASSWORD].SMS[GSM MODEM TELEPHONE #].[IPRS-7 PASSWORD] Used to program the receiver's SMS parameters

Additional Programming Options

SMS Language

Language Value Language Value
English (default) 000 Bulgarian 016
French 001 Romanian 017
Spanish 002 Slovak 018
Italian 003 Chinese 019
Swedish 004 Serbian 020
Polish 005 Malay 021
Portuguese 006 Slovenian 022
German 007 Lithuanian 023
Turkish 008 Finnish 024
Hungarian 009 Estonian 025
Czech 010 French Canadian 026
Dutch 011 Belgian 027
Croatian 012 Latvian 028
Greek 013 Albanian 029
Hebrew 014 Macedonian 030
Russian 015

SMS Programming

Refer to the panel's respective user manual for more information on SMS Personal Reporting.

Section SMS Site Name Label
EVO
[2954] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__
MG/SP
[780] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__

List of SMS Commands

Please note that the default password is admin.

Command Description
P[password].A[IP address].P[port number] Used for LTE/4G/3G/2G remote access
P[password].IP.[call back phone number] Used to obtain the IP address and IP port of the PCS265 LTE and whether or not the "bandwidth saver" option is being used
P[password].RESET Used to power cycle the PCS265 LTE
P[password].VOLOUT.[GSM output volume]

Used to set the GSM output

volume; values range between 50 to 100

P[password].STATUS.[phone number] Used to obtain the signal strength, signal quality, LTE/4G/3G/2G connection status, and APN settings of the current SIM card
P[password].APN1.NAME.[Access Point Name]

Used to program the SIM Card 1

APN

P[password].APN1.USER.[Access Point Name] Used to program the SIM card 1 APN User Name
P[password].APN1.PSW.[Access Point Name] Used to program the SIM card 1 APN Password
P[password].APN1.CLEAR] Used to clear the SIM Card 1 APN
P[password].VAPN1.[CALL BACK PHONENUMBER]

Used to view the SIM Card 2 Access

Point Name information

P[password]. APN2.NAME.[Access Point Name] Used to program the SIM Card 2 Access Point Name
P[password].APN2.USER.[Access Point Name] Used to program the SIM Card 2 Access Point User
P[password].APN2.PSW.[Access Point Name] Used to program the SIM Card 2 Access Point Password
P[password].APN2.CLEAR

Used to clear the SIM Card 2 Access

Point Name

P[password].VAPN2.[CALL BACK PHONE NUMBER] Used to view the SIM Card 2 Access Point Name information
P[password].[IP1W1/ IP1W2/IP2W1/ IP2W2/ IP3W1/IP3W2/IP4W1/ IP4W2].[domain name] Set domain name for LTE/4G/3G/2G receiver
P[password].[IP1W1/ IP1W2/IP2W1/ IP2W2/ IP3W1/IP3W2/IP4W1/ IP4W2].CLEAR Clear domain name for LTE/4G/3G/2G receiver
C[user code].[ARM/OFF].A[area number], [area number], [area number]TO[area number] Arm/Disarm
P[password].---S Disable SWAN polling (V4.10.011 and higher)
P[password].+++S Enable SWAN polling (V4.10.011 and higher)

EN Certification

The following statements apply for EN 50131 and EN 50136 certification:

  • Mode of operation is pass-through
  • PCS265LTE must be installed and connected to an EN approved Grade 3 control panel
  • Monitoring of the transmission network interface (Internet connection): In case of network/interface failure, the device sends a trouble message to the control panel which then displays it via connected keypad(s)
  • Information Security is achieved by 256-bit encrypted, supervised communication (AES validation number 986) which prevents unauthorized reading or modification of messages
  • Substitution Security is achieved by Information Security (as stated above), physical security (Tamper protection) and by a unique Serial Number from each device. Messages sent to the receiving station include the S/N in order to identify the substitution and alert accordingly

Technical Specifications

Specifications Description
RF Power Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)
Antenna Bandwidth 5 bands, wideband
Voltage Input 12 VDC nominal
Consumption during GPRS/GSM transmission 60 mA standby 300 mA maximum
Encryption 128-bit (AES)
SMS Protocol 7-bit (GSM: 3GPP TS 23.038/ GSM03.38) or 16-bit (UCS2 ISO/IEC10646)
SIM Cards LTE/4G/3G GSM (2G - n/a for North and South America)
Humidity 0 - 90% non-condensing
Operating Temperature -20 - 50°C (-4 to 122°F)
Dimensions 20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
Certifications EN 50136-1 EN 50136-2 Grade 3
Class II
EN 50131-10 ATS Category SP5
Certification Body: Applica Test and Certification

Safety Note: This device may operate continuously in temperature of 55°C (131°F)for a maximum period of 7 days.

Warranty

The Limited Warranty Statement can be found on the website www.paradox.com/terms.

Patents

Your use of the Paradox product signifies your acceptance of these terms and conditions. The following US patents may apply 5,886,632 and 6,215,399. Other Canadian and international patents may apply.

©2021 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice.

PARADOX.COM

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Paradox PCS265 LTE Installation And Programming Guide

Advertisement

Need Assistance?

Do you have a question about the PCS265 LTE that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents