The PCS265 LTE supports two nano LTE/4G/3G/2G or GSM provider SIM cards. To install the SIM cards, open the SIM Card tray and insert card into base, as shown. SIM Card 1 is used as "Primary" and SIM Card 2 for "Backup".
Note: SIM Card 2 can only be configured via SMS.
Connect the PCS265 LTE's serial out to the serial connector on the panel.
A CVT485 module can be connected onto the control panel's EBUS in order to lengthen the distance (up to 300 m. / 1000 ft.) between the panel and the PCS265 LTE. Refer to the drawing for connections.
Use the ANTK4G LTE external antenna kit for PTCRB installations or to improve RF reception if your module's signal strength is weak.
External antenna kits and extension kits are purchased separately.
The PCS265 LTE can be connected to an IP Internet Module's PCS port. For more information on how to configure this option, please refer to the IP module's Installation manual.
Once your hardware connections are completed, the PCS265 LTE module will begin its power up sequence.
If configured for LTE/4G/3G/2G reporting, you will need to configure network provider information. Refer to the Programming section.
Note: The battery is optional. If a battery is used/installed, do not allow the battery to deplete and ensure that the battery is replaced when low.
The battery function is to support power shut down and not to be used as backup as defined in EN50131-6.
LED | Functionality |
SIM1 and SIM2* | Slow orange flashing - Searching the network Solid purple - LTE/4G Solid blue - 3G Solid orange - GSM Solid green - 2G (n/a for North and South America) Quick flashing - Exchanging data (the color of the flashing LED corresponds to the color of LTE/4G/3G/2G or GSM depending on which is being used) Off - SIM card 1 or 2 is not installed, not active, or currently not in use |
Power | Solid green Off - No power |
Status | Red - Error condition, no firmware Red/Green alternating - updating firmware Green - No error and/or battery fully charged Orange - Battery charging |
Signal Strength | Three LEDs indicate network strength |
All LEDs (except power) | Flashing - No data communication |
*When using an e-bus connection, the LED is always orange.
In order to configure the PCS265 LTE for reporting, you will need to first configure your SIM cards. Please note that SIM Card 1 can be configured via panel programming and SIM Card 2 via SMS.
(Serial Port or via SMS Connection ONLY)
Network Provider Information
MG/SP | EVO | Feature |
[921] | [2960] | APN part 1 (characters 1-16) |
[922] | [2961] | APN part 2 (characters 17-32) |
[923] | [2962] | APN user name part 1 (1-16) |
[924] | [2963] | APN user name part 2 (17-32) |
[925] | [2964] | APN password part 1 (1-16) |
[926] | [2965] | APN password part 2 (17-32) |
This information can be obtained from your mobile network provider. |
Network Provider Information
Refer to the List of SMS Commands Table.
LTE/4G/3G/2G Reporting Options
MG/SP | EVO | Feature | Details | |
[918] [919] | [2976] to [2983] | Account / Partition Registration | MG/SP: Sections represent account/ partition 1 and 2 EVO: Sections represent account / partition 1 to 8 | |
[806] | [2975] | [7] Off + [8] Off = landline only [7] Off + [8] On = LTE/4G/3G/2G primary / landline backup (default) [7] On + [8] Off = landline only [7] On + [8] On = landline and LTE/4G/3G/2G in parallel | ||
Receiver Settings | MG/SP | |||
Receiver #: | 1 | 2 | Backup | |
IP address* | [929] | [936] | [943] | |
IP port ** | [930] | [937] | [944] | |
IP address WAN 2 | [931] | [938] | [945] | |
IP port WAN2 | [932] | [939] | [946] | |
Receiver password | [933] | [940] | [947] | |
Security Profile | [934] | [941] | [948] | |
Module registration Press [ARM] to register | [935] | [942] | [949] | |
Receiver Settings | EVO | |||
Receiver #: | 1 | 2 | 3 | 4 |
IP address* | ||||
IP port ** | ||||
IP address WAN 2 | [2984] | [2986] | [2988] | [2990] |
IP port WAN2 | ||||
Receiver password | ||||
Security Profile | ||||
Module registration Press [ARM] to register | [2985] | [2987] | [2989] | [2991] |
* For 1 or 2 digit numbers, add "0's" before the digit: e.g., 138.002.043.006 ** Default = 10000 Enter [MEM] for blank space |
MG/SP | EVO | Details |
[805] | [2950] | [1] Off + [2] Off = landline only (default) [1] Off + [2] On = landline primary / GSM backup (default) [1] On + [2] Off = GSM primary / landline backup [1] On + [2] On = GSM only |
[815] to [817] | [3071] to [3074] | Telephone numbers |
[811] to [812] | [3061] to [3068] | Account numbers |
Command | Description |
P[PASSWORD].SMS[GSM MODEM TELEPHONE #].[IPRS-7 PASSWORD] | Used to program the receiver's SMS parameters |
Language | Value | Language | Value |
English (default) | 000 | Bulgarian | 016 |
French | 001 | Romanian | 017 |
Spanish | 002 | Slovak | 018 |
Italian | 003 | Chinese | 019 |
Swedish | 004 | Serbian | 020 |
Polish | 005 | Malay | 021 |
Portuguese | 006 | Slovenian | 022 |
German | 007 | Lithuanian | 023 |
Turkish | 008 | Finnish | 024 |
Hungarian | 009 | Estonian | 025 |
Czech | 010 | French Canadian | 026 |
Dutch | 011 | Belgian | 027 |
Croatian | 012 | Latvian | 028 |
Greek | 013 | Albanian | 029 |
Hebrew | 014 | Macedonian | 030 |
Russian | 015 |
Refer to the panel's respective user manual for more information on SMS Personal Reporting.
Section | SMS Site Name Label |
EVO | |
[2954] | __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ |
MG/SP | |
[780] | __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ |
Please note that the default password is admin.
Command | Description |
P[password].A[IP address].P[port number] | Used for LTE/4G/3G/2G remote access |
P[password].IP.[call back phone number] | Used to obtain the IP address and IP port of the PCS265 LTE and whether or not the "bandwidth saver" option is being used |
P[password].RESET | Used to power cycle the PCS265 LTE |
P[password].VOLOUT.[GSM output volume] | Used to set the GSM output volume; values range between 50 to 100 |
P[password].STATUS.[phone number] | Used to obtain the signal strength, signal quality, LTE/4G/3G/2G connection status, and APN settings of the current SIM card |
P[password].APN1.NAME.[Access Point Name] | Used to program the SIM Card 1 APN |
P[password].APN1.USER.[Access Point Name] | Used to program the SIM card 1 APN User Name |
P[password].APN1.PSW.[Access Point Name] | Used to program the SIM card 1 APN Password |
P[password].APN1.CLEAR] | Used to clear the SIM Card 1 APN |
P[password].VAPN1.[CALL BACK PHONENUMBER] | Used to view the SIM Card 2 Access Point Name information |
P[password]. APN2.NAME.[Access Point Name] | Used to program the SIM Card 2 Access Point Name |
P[password].APN2.USER.[Access Point Name] | Used to program the SIM Card 2 Access Point User |
P[password].APN2.PSW.[Access Point Name] | Used to program the SIM Card 2 Access Point Password |
P[password].APN2.CLEAR | Used to clear the SIM Card 2 Access Point Name |
P[password].VAPN2.[CALL BACK PHONE NUMBER] | Used to view the SIM Card 2 Access Point Name information |
P[password].[IP1W1/ IP1W2/IP2W1/ IP2W2/ IP3W1/IP3W2/IP4W1/ IP4W2].[domain name] | Set domain name for LTE/4G/3G/2G receiver |
P[password].[IP1W1/ IP1W2/IP2W1/ IP2W2/ IP3W1/IP3W2/IP4W1/ IP4W2].CLEAR | Clear domain name for LTE/4G/3G/2G receiver |
C[user code].[ARM/OFF].A[area number], [area number], [area number]TO[area number] | Arm/Disarm |
P[password].---S | Disable SWAN polling (V4.10.011 and higher) |
P[password].+++S | Enable SWAN polling (V4.10.011 and higher) |
The following statements apply for EN 50131 and EN 50136 certification:
Specifications | Description |
RF Power | Class 4 (2W) @ 850/1900 MHz Class 2 (1W) @ 1800/1900 MHz UMTS 850/1900 @ 0.25W (America) UMTS 900/2100 @ 0.25W (Europe) |
Antenna Bandwidth | 5 bands, wideband |
Voltage Input | 12 VDC nominal |
Consumption during GPRS/GSM transmission | 60 mA standby 300 mA maximum |
Encryption | 128-bit (AES) |
SMS Protocol | 7-bit (GSM: 3GPP TS 23.038/ GSM03.38) or 16-bit (UCS2 ISO/IEC10646) |
SIM Cards | LTE/4G/3G GSM (2G - n/a for North and South America) |
Humidity | 0 - 90% non-condensing |
Operating Temperature | -20 - 50°C (-4 to 122°F) |
Dimensions | 20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in. |
Certifications | EN 50136-1 EN 50136-2 Grade 3 Class II EN 50131-10 ATS Category SP5 Certification Body: Applica Test and Certification |
Safety Note: This device may operate continuously in temperature of 55°C (131°F)for a maximum period of 7 days.
The Limited Warranty Statement can be found on the website www.paradox.com/terms.
Your use of the Paradox product signifies your acceptance of these terms and conditions. The following US patents may apply 5,886,632 and 6,215,399. Other Canadian and international patents may apply.
©2021 Paradox Security Systems (Bahamas) Ltd. All rights reserved. Specifications may change without prior notice.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Paradox PCS265 LTE Installation And Programming Guide
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the PCS265 LTE that isn't answered in the manual? Leave your question here.