. xxxi Safety notices . . xi Related IBM publications . . xxxii Power cords . . xii IBM System Storage TS7600 with ProtecTIER Environmental notices . xiii publications . . xxxii TS7650G 3958 DD3 publications. . xxxii Safety, danger, caution notices and DS4700 Express Disk Controller (1814 70H) labels .
Page 6
Industries Association (JEITA) Statement (less than or equal to 20 A per phase) . . 146 Chapter 14. Testing a clustered system 97 Korean Communications Commission (KCC) Class A Statement . . 147 IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 7
Russia Electromagnetic Interference (EMI) Class Index ....149 A Statement . . 147 Contents...
Page 8
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Tables IBM Web sites for help, services, and Clustered fibre channel connections . 37 information . . xxix Power-on sequences. . 38 Server rear view: Slot assignments, ports, and TSSC Interface . 44 connections . Company information worksheet . . 101 Responsibilities matrix .
Page 12
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Most danger or caution notices contain a reference number (Dxxx or Cxxx). Use the reference number to check the translation in the IBM Systems Safety Notices, G229-9054 manual. The sections that follow define each type of safety notice and give examples.
Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
The cord set should have the appropriate safety approvals for the country in which the equipment will be installed. IBM power cords for a specific country or region are usually available only in that country or region.
Page 16
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
hazardous voltages, disconnect all power cords. v Connect all power cords to a properly wired and grounded electrical outlet. Ensure that the outlet supplies proper voltage and phase rotation according to the system rating plate. v Connect any equipment that will be attached to this product to properly wired outlets.
Repair or disassemble Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
C009 CAUTION: >18 kg (39.7 lb) 18-32 kg (39.7-70.5 lb) The weight of this part or unit is between 18 and 32 kg (39.7 and 70.5 lb). It takes two persons to safely lift this part or unit. (C009) C013 CAUTION: The doors and covers to the product are to be closed at all times except for service by trained service personnel.
Page 22
Note the following information: v Laser radiation when open. v Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. (C030) IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 23
C031 CAUTION: The power-control button on the device does not turn off the electrical current supplied to the device. The device might also have more than one connection to dc power. To remove all electrical current from the device, ensure that all connections to dc power are disconnected at the dc power input terminals.
Page 24
(For fixed drawers): This drawer is a fixed drawer and must not be moved for servicing unless specified by the manufacturer. Attempting to move the xxii IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 25
drawer partially or completely out of the rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001 part 2 of 2) R002 CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation.
Page 26
Rack-mounted devices are not to be used as shelves or work spaces. (L002) L003 DANGER Multiple power cords. The product might be equipped with multiple power cords. To remove all hazardous voltages, disconnect all power cords. (L003) xxiv IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 27
L004 DANGER Hazardous voltage present. Voltages present constitute a shock hazard, which can cause severe injury or death. (L004) Safety, danger, caution notices and labels...
Page 28
L009 CAUTION: System or part is heavy. The label is accompanied by a specific weight range. (L009) L013 DANGER Heavy equipment—personal injury or equipment damage might result if mishandled. (L013) xxvi IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 29
L015 CAUTION: Danger! Arc Flash/Arc Blast hazard when disconnected with power on. Turn off power before disconnecting. (L015) L022 CAUTION: Class 3R visible and invisible laser radiation when open. Avoid direct eye exposure. (L022) L023 CAUTION: Laser Aperture (L023) xxvii Safety, danger, caution notices and labels...
Page 30
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
If you need help, service, technical assistance, or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. Available services, telephone numbers, and Web links are subject to change without notice.
Help and service You can call 1 (800) IBM SERV for help and service if you are in the U.S. or Canada. You must choose the software or hardware option when calling for assistance. Note: This product is equipped with a Software Call Home feature. When enabled, it will notify IBM Service of software error events.
Page 33
IBM Support Center (1 800 426-7378 in the U.S.) for product assistance covered under the terms of the hardware IBM warranty or the software maintenance contract that comes with product purchase. Please have the following information ready when you call: v Either machine type and model or software identifier.
Page 34
The following publications provide additional documentation about the gateway server: v IBM System x3850 M2 and System x3950 M2 Type 7141 and 7233 User's Guide v IBM System x3850 M2 and System x3950 M2 Type 7141 and 7233 Problem Determination and Service Guide The server might have features that are not described in the documentation that you received with the server.
Page 35
IBM XIV Storage System publications The following publications provide additional documentation about the IBM XIV Storage System: v IBM XIV Storage System (Types 2810 and 2812) Model A14 (Gen2) Introduction and Planning Guide for Customer Configuration v IBM XIV Storage System User Manual...
Page 36
Your feedback is important in helping to provide the most accurate and highest quality information. To submit any comments about this book or any other IBM System Storage TS7600 with ProtecTIER documentation: v Send your comments by e-mail to starpubs@us.ibm.com. Be sure to include the following information: –...
Page 37
The IBM System Storage TS7650G ProtecTIER De-duplication Gateway (TS7650G) is available in two configurations — stand-alone and clustered. Note: IBM does not support more than one clustered pair of TS7650 Gateway servers in a single frame. The purchase of the stand-alone gateway includes: v One gateway server (IBM machine type and model 3958 DD3).
Page 38
These are terms for IBM's virtualization solution from the TS7650 family that does not include a disk storage repository, allowing the customer to choose from a variety of storage options. IBM does not support more than one clustered pair of TS7650 Gateway servers in a single frame. The...
Page 39
Disk controller The customer must choose the disk controller for use with the TS7650G. A list of compatible controllers is located at the IBM Tape Systems Resource Library Web site: http://www-03.ibm.com/ systems/storage/tape/library.html#compatibility in the TS7650/TS7650G ISV and interoperability matrix document.
Page 40
This document does not address the following topics: v Installation of the second dual-port Ethernet adapter in a legacy 3958 DD1 server, to prepare the server for use in replication. Refer to the IBM(r) System Storage(tm) TS7600 with ProtecTIER Second Dual-Port Ethernet Card (Feature Code 3448) Installation Instructions, IBM part number 45E6768.
The TS7650G documentation CD contains the following service and customer documentation for the TS7650G: v IBM System Storage TS7600 with ProtecTIER Installation Roadmap Guide for the TS7650G (3958 DD3), IBM form number GC53–1154 v IBM System Storage TS7600 with ProtecTIER Introduction and Planning Guide for the TS7650G (3958 DD3), IBM form number GC53–1152...
Page 42
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 1 on page 8 shows only the TS7650G components installed in the server frame. Important: v IBM does not support more than one clustered pair of TS7650 Gateway servers in a single frame. v Hardware components included in the purchase of the gateway are listed in bold type below.
One IBM TS3000 System Console (TSSC) and TSSC Ethernet switch v Two 36u frames ® Note: For convenience, the Windows version of the DS4000 Storage Manager application is provided on the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD. Storage Manager is used to monitor the health and connectivity status of the recommended disk components, and to perform service and disk rebuilding tasks.
About the TS7650G server The TS7650G stand-alone and clustered gateways come with one or two servers, respectively. The servers are equipped with two Emulex fibre channel host bus adapters, two Qlogic host bus adapters, two 1Gb Ethernet adapters, and two on-board Ethernet ports.
Page 46
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
EXP810 disk expansion modules (1812 81H) in many of the hardware installation figures, examples, and procedures. In addition to the IBM DS4700 disk controller, the TS7650G also supports the DS5000 disk controller and the XIV disk controller. If the customer has elected to...
(CSU), or not considered to be IBM setup such as third-party disk storage subsystems. TS7650G sales agreements may include a frame and disk storage as part of the order.
The flowcharts for upgrading legacy 3958 DD1, 3958 DD3, or 3958 AP1, servers are located in the IBM System Storage ProtecTIER Software Upgrade and Replication Enablement Guide, IBM form number GC53–1196.
3958 DD3 or 3958 AP1 Enabling Replication? Yes or No Software Upgrade and Replication Enablement Guide User’s Guide Figure 3. Documents required to install a new stand-alone 3958 DD3 server IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
(1812 81H) in many of the hardware installation figures, examples, and procedures. In addition to the IBM DS4700 disk controller, the TS7650G also supports the DS5000 disk controller and the XIV disk controller. If the customer has elected to...
Page 53
If the customer purchased a new TSSC and The TSSC Maintenance Information (MI), TSSC Ethernet switch and has not yet installed provided on the IBM System Storage TS7650 them, do so now then go to task 3-1. with ProtecTIER Publications CD.
“Stand-alone gateway installation checklist” on page 16. Important: This document references IBM DS4700 disk controllers (1814 70H) and IBM EXP810 disk expansion modules (1812 81H) in many of the hardware installation figures, examples, and procedures.
Page 55
In addition to the IBM DS4700 disk controller, the TS7650G also supports the DS5000 disk controller and the XIV disk controller. If the customer has elected to use disk storage components other than the IBM DS4700 disk controllers (1814 70H) mentioned above, the figures, examples, and procedures in this document will not apply to the configuration on which you are working.
Page 56
“Cabling a clustered gateway” on page 32. Server B to the TSSC's Ethernet switch. 3–16 Label and connect an Ethernet cable from “Cabling a clustered gateway” on page 32. Server B to the customer's LAN. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 57
Table 5. Clustered gateway installation checklist (continued) Task Description Where to find information 3–17 Label and connect an Ethernet cable from the “Cabling a clustered gateway” on page 32. RSA on Server B to the TSSC's Ethernet switch. 3–18 Label and connect an Ethernet cable from “Cabling a clustered gateway”...
Important: If the customer purchased a TSSC, you are required to install it and its related components, along with the other gateway hardware. Failure to do so will prevent the use of Call Home or IBM remote support. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 59
Procedure 1. Physically install the TSSC and its related components into the server frame. Use the documentation provided with the TSSC for installation instructions. Attention: The recommended location for installing the TSSC is in EIA Unit 18. Use EIA holes 52, 53, and 54 for the installation of the rail assembly for the TSSC.
This is required so that the power receptacles are easily accessible for power connections. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
About this task Notes: v IBM best practices recommends installing the 1 Gb Ethernet switches near the bottom of the clustered gateway server frame. See Figure 1 on page 8. v When performing the installation, use caution to avoid dislodging or damaging the cabling within the frame.
Repeat the above steps for the right side rail and ensure that both side rails are secure. 3. Install the air duct housing in the frame. To do so, working from the front side of the frame: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Applying cable labels About this task Use the IBM System Storage TS7600 with ProtecTIER Labeling Instructions for the TS7650/TS7650G (3958 DD1, 3958 DD3, 3958 AP1), IBM part number 46X4256 for label placement guidelines and instructions. When applying labels, align the center reference lines on the label with the axis of the cable.
On Device/Location Power outlet TSSC Bottom PDU Power outlet TSSC Top PDU Power outlet TSSC Ethernet switch Bottom PDU Power outlet TSSC Ethernet switch Top PDU Power outlet Server Bottom PDU IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Table 6. Stand-alone power connections (continued) From On Device On Device/Location Power outlet Server Top PDU Procedure 1. Label and connect the power cords according to Figure 8 on page 28 and Table 6 on page 28. Note: Depending on the TSSC's configuration, the TSSC may have one or two power supplies.
If so, make the cable connections according to the port number assignments specified in Table 7 on page 29, regardless of the position of the ports on the TSSC or the switch. Refer to the IBM System Storage TS3000 System Console (TSSC) Maintenance Information for detailed port information.
For consistency and ease when troubleshooting, you may want to relocate the PDUs to match Figure 11 on page 33. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Ethernet switch 2 Port 1, slot 4 Server A Port 2 Ethernet switch 2 Port 1, slot 4 Server B Port 3 Ethernet switch 2 Ethernet port, E WTI network power switch IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Table 10. Clustered 1 GB Ethernet switch Ethernet connections (continued) From On Device On Device/Location Port 4 Ethernet switch 2 Port 4 Ethernet switch 1 Port 1 Ethernet switch 1 Port 2, slot 3 Server A Port 2 Ethernet switch 1 Port 2, slot 3 Server B Procedure...
If so, make the cable connections according to the port number assignments specified in Table 11 on page 35, regardless of the position of the ports on the TSSC or the switch. Refer to the IBM System Storage TS3000 System Console (TSSC) Maintenance Information for detailed port information.
The RAS code no longer sends call home packages for problems with any of the disk storage products attached to the gateway including DS4700, DS5000, and XIV. However, if the IP address of an SMTP server is provided during RAS package configuration, the disk storage subsystems that communicate with the RAS package (which includes DS4700 and DS5000 if they have firmware levels supported by RAS) will send problem reports to the customer via email.
(1812 81H) in many of the hardware installation figures, examples, and procedures. In addition to the IBM DS4700 disk controller, the TS7650G also supports the DS5000 disk controller and the XIV disk controller. If the customer has elected to...
Disk controllers About this task For power-on instructions, refer to the IBM System Storage DS4700 Express Storage Subsystem Installation, User's and Maintenance Guide. Important: Precautions must be taken when turning on the disk controllers to prevent damage to the controllers' enhanced disk drive module (E-DDM) hard drives.
Figure 15. Server operator panel For more detailed information, refer to the IBM System x3850 M2 and System x3950 M2 Type 7141 and 7233 User's Guide that was provided with the server. TSSC, display panel, and TSSC Ethernet Switch About this task To turn on the TSSC, press the white power-control button.
Page 77
Instructions for doing so appear in the IBM System Storage ProtecTIER User's Guide for Enterprise Edition and Appliance Edition, IBM form number GC53–1156.
Page 78
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
4. When Call Home setup is complete, return to this page and go to step 5. 5. Right-click on the TSSC's blue desktop. The IBM TS3000 System Console menu displays. See Figure 16 on page 44. 6. Select System Console Actions → Console Configuration Utility.
The Console Configuration application starts and the Console Configuration utility screen displays: Figure 17. Console configuration utility screen 9. Click Console Settings The Console Settings screen displays. See Figure 18 on page 45. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 18. Console Settings screen 10. In the Internal Network Interface pane, verify that the IP Address: 172.31.1.1 and the Subnet mask: 255.255.0.0, are displayed. Note: If different values display in the Internal Network Interface pane, change them to match the IP Address and Subnet mask values provided above.
Stop NTP server. b. In the Time fields, enter the current UTC. c. Click Save Changes. 17. Click Start NTP server. The Console Time and Date screen re-displays with the new UTC shown: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 20. Console Time and Date screen: NTP server running 18. Close the Console configuration utility screen. You are returned to the TSSC's blue desktop. 19. Go to Chapter 6, “Configuring the RAS package,” on page 49. Chapter 5. Setting up the TSSC for use with the TS7650G...
Page 84
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
On the TSSC, right-click on the blue desktop. The IBM TS3000 System Console menu displays. v Make note of the TSSC code level, displayed in the IBM TS3000 System Console title bar. Note: For detailed information about TSSC code installation and cable...
8. Verify that an existing TSSC meets the minimum hardware requirements. See the IBM System Storage TS3000 System Console (TSSC) Maintenance Information provided on the IBM System Storage TS7650 with ProtecTIER Publications CD in the TS7650G ship group. About this task The RAS package configuration procedure performs the following tasks: v Sets up the TSSC network (172.31.1.xxx) for the servers and the RSAs.
Page 87
Disk array serial number v Customer number v Country code Note: This is the two-digit, IBM-assigned country code used to order software or to acquire software support. Do not confuse this with the three-digit RETAIN country code. v Simple Mail Transfer Protocol (SMTP) server IP address (optional)
Disk array machine type and model number v Disk array serial number v Customer number v Country code Note: This is the two-digit, IBM-assigned country code used to order software or to acquire software support. Do not confuse this with the three-digit RETAIN country code.
(You may need to enter the entire command string: /opt/dtc/install/ptconfig -configRas). c. Follow the on-screen instructions to complete the configuration process. Important: v If you receive an error that the frame range number entered is already in use, specify a different range in an increment of 10. For example, if frame range 20 is already in use, try frame range 30.
Page 90
100baseT/Half 100baseT/Full 1000baseT/Full Advertised auto-negotiation: Yes Speed: 1000Mb/s Duplex: Full Port: Twisted Pair PHYAD: 1 Transceiver: internal Auto-negotiation: on Supports Wake-on: d Wake-on: d Current message level: 0x00000001 (1) Link detected: yes IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 91
3. Note the results of the above procedures and pass them on to the trained ProtecTIER specialist/LBS representative for use during ProtecTIER configuration. 4. Go to Chapter 7, “RAS verification,” on page 57. Chapter 6. Configuring the RAS package...
Page 92
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
1. If you are not already logged into the TSSC do so now, with the username service and the password service. 2. Right-click on the TSSC's blue desktop. The IBM TS3000 System Console menu displays. 3. System Console Actions → Console Configuration Utility If prompted for a username and password, enter service in both fields.
7. Click Done. The ProtecTIER Manager Installation wizard closes and the TSSC's CD-ROM drive opens. 8. Remove the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD, close CD-ROM drive, then go to Chapter 11, “Using ProtecTIER Manager,” on page Calibrating the server battery Each server contains a battery that must be calibrated.
Test Call Home – Triggered from the RAS command line interface (CLI) to test the path to the IBM Customer Configuration Profile File (CCPF) system. v User Initiated Call Home – Triggered from the TSSC graphical user interface...
Page 96
The portion of the TS7650G installation and configuration for which the SSR is responsible is now complete. 7. Turn the system over to the trained ProtecTIER specialist for LBS representative for installation and configuration of ProtecTIER and ProtecTIER Manager. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Reinstalling Red Hat Linux is a customer responsibility. Should doing so become necessary, refer the customer to the Recovery appendix of the IBM System Storage ProtecTIER User's Guide for Enterprise Edition and Appliance Edition, IBM form number GC53–1156, provided on the IBM System Storage TS7650 with ProtecTIER Publications CD, for detailed instructions.
The above information can be found on the completed IP Address Worksheet, located in the IBM System Storage TS7600 with ProtecTIER Introduction and Planning Guide for the TS7650G (3958 DD3), IBM form number GC53–1152. A blank copy of this worksheet is provided in this document for your convenience.
Configuration instructions for legacy 3958 DD1, 3958 DD3, or 3958 AP1 servers are provided in the IBM System Storage ProtecTIER Software Upgrade and Replication Enablement Guide, IBM form number GC53–1196.
Page 100
Gathering System information [ Done ] The auto-detected system information displays. For example: Target Target Netmask Local Gateway Network Address Address 10.11.194.0 255.255.255.0 10.11.195.1 10.11.196.0 255.255.255.0 10.11.197.1 Followed by the Available Options prompt: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 101
Available Options: ================== (a)dd a new record (e)dit a record (d)elete a record (c)ommit changes (q)uit Please Choose (a,e,d,c,q): 6. Type: a <enter> You are prompted to enter information for the first destination (target - eth3) server and the local network. Attention: Do not configure the replication ports Eth3 and Eth4 on the same subnet as the external LAN port Eth0.
Page 102
Site 2 – Server A Target Network Address Target Netmask Local Gateway Address (Remote node's starting (Remote node's netmask) (The gateway address for network address) Server A at Site 2) 1 (eth3) 2 (eth4) IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Site 2 – Server B Target Network Address Target Netmask Local Gateway Address (Remote node's starting (Remote node's netmask) (The gateway address for network address) Server B at Site 2) 1 (eth3) 2 (eth4) The Available Options prompt displays a third time: Available Options: ================== (a)dd a new record...
Page 104
Note: For a detailed description of what the fsCreate tool does, or to manually create file systems using the Linux Command Line Interface (CLI), refer to the IBM System Storage ProtecTIER User's Guide for Enterprise Edition and Appliance Edition, IBM form number GC53–1156.
About this task The ProtecTIER Replication Manager application is installed on a customer-designated ProtecTIER v2.4 server. IBM recommends installing ProtecTIER Replication Manager at the replication destination site, so that the ProtecTIER Replication Manager will remain available in a disaster recovery situation.
Page 106
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Important: If an older version of ProtecTIER Manager is already installed on the ProtecTIER Manager workstation or the TSSC, make sure the ProtecTIER Manager GUI is closed before installing the newer version from the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD.
The Choose Install Folder window opens: Figure 22. Choose Install Folder window 4. Specify the folder where the ProtecTIER Manager program files will be installed, and then click Next. The Choose Shortcut Folder window opens: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 23. Choose Shortcut Folder window 5. Select the location where the program icons will be created: v In a new Program Group – Creates a new program group in the Program list of the Start menu. v In an existing Program Group – Adds the shortcut to an existing program group in the Program list of the Start menu.
About this task To install ProtecTIER Manager on Linux: Procedure 1. Insert the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD into the CD-ROM drive of the designated ProtecTIER Manager workstation. 2. Run the ProtecTIER Manager installer. To do so: a. From the Linux desktop, double-click the CD-ROM icon, and then double-click the installation folder for the version of Linux you are using.
Page 111
In your Home folder – Creates the links in the directory where the user's files are typically stored. For example: /home/bill. v Other – Creates the links in the default location (/opt/IBM/PTManager). To specify a different location, click Choose and select a directory on the workstation's hard drive.
Page 112
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Go to step 2 on page 78. If the ProtecTIER Manager GUI is installed on a Windows-based workstation a. Click Start → Programs → IBM → ProtecTIER Manager 2.3.2.0 → IBM ProtecTIER Manager. The ProtecTIER Manager screen opens. See Figure 25 on page 78.
Systems tab of the Navigation pane. If the cluster contains a second node, that node displays in the Nodes pane. 6. Go to “Planning the repository” on page 79. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Planning the repository Use the Repository Planning wizard in conjunction with guidance from IBM support, to determine the optimum repository size and meta data file system arrangement for the repository. Procedure 1. On the ProtecTIER Manager workstation, run ProtecTIER Manager.
Note: Creating a repository is a prerequisite for adding a second node to a cluster, as repository creation must be performed on Node A. Procedure 1. On the ProtecTIER Manager workstation, if it is not already running, run the ProtecTIER Manager application. To do so: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Click Start → Programs → IBM → ProtecTIER Manager 2.3.2.0 → IBM ProtecTIER Manager. The ProtecTIER Manager window opens. 2. In the Nodes pane, select the node on which to create the repository. 3. Select Create repository. The Create repository wizard starts the data collection process. When data collection is complete, the Welcome window opens.
Create repository planning wizard. b. In the Estimated factoring ratio field, enter the estimated factoring ratio value that was determined with the assistance of IBM Support personnel. c. In the System peak throughput (MB/Sec) field, specify the rate of system peak throughput that the meta data file systems can support.
Figure 30. Storage window 9. Click Next. The Repository resources dialog box opens. See Figure 31. Figure 31. Repository resources dialog 10. Verify that the correct file systems are selected for meta data and user data, based on the meta data file system sizes indicated by the repository planning process.
Page 120
15. Proceed as appropriate: v If this is a stand-alone configuration, TS7650G installation and setup is now complete. Turn the system over to the customer and refer them to the IBM System Storage ProtecTIER User's Guide for Enterprise Edition and Appliance Edition, IBM form number GC53–1156, for information on customizing,...
Page 122
./ptconfig -staticRoutes <enter> The message below displays: Gathering System information [ Done ] The auto-detected system information displays. For example: Target Target Netmask Local Gateway Network Address Address 10.11.194.0 255.255.255.0 10.11.195.1 IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 123
10.11.196.0 255.255.255.0 10.11.197.1 Followed by the Available Options prompt: Available Options: ================== (a)dd a new record (e)dit a record (d)elete a record (c)ommit changes (q)uit Please Choose (a,e,d,c,q): 15. Type: a <enter> You are prompted to enter information for the first destination (target - eth3) server and the local network.
Page 124
Site 2 – Server A Target Network Address Target Netmask Local Gateway Address (Remote node's starting (Remote node's netmask) (The gateway address for network address) Server A at Site 2) 1 (eth3) IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 125
Site 2 – Server A 2 (eth4) Site 2 – Server B Target Network Address Target Netmask Local Gateway Address (Remote node's starting (Remote node's netmask) (The gateway address for network address) Server B at Site 2) 1 (eth3) 2 (eth4) The Available Options prompt displays a third time: Available Options: ==================...
1) From the ProtecTIER Manager menu bar, select Cluster Management → Add Cluster Member. The Add cluster member wizard Welcome screen opens. 2) Click Next. The Server Selection screen opens. See Figure 33 on page 91. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 33. Server selection screen 3) In the Server IP field of the Server Selection pane, enter the IP address of the Server you want to add to the cluster. Alternatively, you can select the IP address from the dropdown list. 4) Click Next and then click Finish The Add cluster member wizard closes and the Server is added to the selected cluster.
Page 128
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Attention: If you are running the setClock configuration to change the date and time, IBM recommends that once you complete the procedure, you commit the changes and exit the session. Do not proceed to setting a different timezone in the same session.
Page 131
If you typed m to manually enter the timezone, the following is displayed: Enter the time zone (case sensitive): Type, for example, Italy <Enter>. 10. Type a number corresponding to the timezone you want to synchronize from the list under the country code entered. The following is displayed: Date, Time, Timezone &...
Page 132
[ Done ] Setting Time Zone [ Done ] Setting Timeserver [ Done ] Setting Date & Time [ Done ] Starting NTPD [ Done ] Starting cluster [ Done ] Cluster Started IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
To do so, on the ProtecTIER Manager workstation, click Alerts in the lower right corner of the ProtecTIER Manager screen. The Alerts Log opens. See Figure 34 on page 99. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Alerts Log screen. 10. If the test succeeds on both nodes, TS7650G installation and setup is complete. Turn the system over to the customer and refer them to the IBM System Storage ProtecTIER User's Guide for Enterprise Edition and Appliance Edition, IBM form number GC53–1156 for information on customizing, using, and...
7. Log out of the server. Verifying configuration of recommended disk storage components Important: The procedure below applies to IBM DS4700 disk storage, only. To confirm that the disk storage is properly configured: 1. Log into the stand-alone server, or Server A in a cluster: a.
IBM service representatives use the information that is provided on the company information worksheet to customize your IBM storage complex. When you use any of the remote support features, the TSSC sends this information to IBM so an IBM service representative can contact you.
Page 138
Call back phone number The phone number of the modem being used for Call Home. Include the area code and the country code, if appropriate. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 139
Your information Disk array machine type(s) and The machine type(s) and model model number(s) number(s) for the attached disk array storage subsystem(s). For non-IBM equipment, also provide vendor name(s). Use an additional sheet if necessary. Disk array serial number(s) The serial number(s) for the attached disk array storage subsystem(s).
Haiti Montserrat Seychelles Zaire Island Cocos Heard and Morocco Sierra Leon Zambia (Keeling) McDonald Islands Islands Colombia Honduras Mozambique Singapore Zimbabwe Comoros Hong Kong Myanmar Slovak Republic Congo Hungary Namibia Slovenia IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Appliancecomponents. IBM service representatives use the information provided to define the IP addresses of components supported by the TSSC. When the TSSC sends Call Home information to IBM through VPN or modem, or sends you notices about serviceable events, these settings will be included in the information to identify and provide important information about the TSSC that sent a service request.
Provide a routing path from the IP address on eth3-server1 to the IP address of eth3-server2, and a routing path from the IP address on eth4-server1 to the IP address of eth4-server2. Source Site IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Table 20. Customer and Replication IP addresses (continued) Node A (the Port IP Address Network Mask Default Gateway Dedicated VLAN server located in eth3 the lower part of the rack) eth4 Node B (the Port IP Address Network Mask Default Gateway Dedicated VLAN server located in eth3 the upper part of...
A single frame is ten IPs, and each node within a frame requires its own set of ten IPs – from 0 to 9. If there are no attached devices/systems, the first usable frame would be 10. For example: v 172.31.1.10 - 172.31.1.19 would be considered frame 10 IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
1 (server A). For example, if server A is set for 172.31.1.10 then server B will be set for 172.31.1.15. Note: Depending upon the address ranges available on the TSSC, the IBM Service representative may have to use ranges other than those shown here.
Page 146
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Depending upon the equipment you have available, you will perform the procedures that follow using a USB keyboard and graphics-capable monitor (the preferred method), or the TSSC (code-level 5.7.8 or higher) or your IBM service laptop. Tip: If you connect to the RSA using your service laptop, you may need an extension cord to reach a standard power outlet, or a 240v to 110v step-down voltage converter to allow the laptop to run on a PDU in the server frame.
Figure 35. Service laptop to RSA connection 3. On the laptop, click Start → Control Panel. 4. Double-click Network Connections. 5. Right-click Local Area Connection → Properties. See Figure 36 on page 115. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Figure 36. Local Area Connection Properties 6. From the list, select Internet Protocol (TCP/IP), then click Properties. 7. Select Use the following IP address. 8. In the IP Address field, type: 172.31.1.14 (or 192.168.70.33 if the RSA is a new FRU), and in the Subnet mask field, type: 255.255.255.0. 9.
OK. Note: The username and password are case sensitive and must be entered in all uppercase. The Remote Supervisor Adapter II Refresh 1 Welcome window opens. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
About this task Procedure 1. In the Remote Supervisor Adapter II Refresh 1 window, click Remote Control found in the left-hand menu under the IBM logo. 2. In the Remote Control window, click Start Remote Control in Single User Mode.
Page 154
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 156
Alagoas, Sergipe America/Bahia Bahia America/Sao_Paulo S & SE Brazil (GO, DF, MG, ES, RJ, SP, PR, SC, RS) America/Campo_Grande Mato Grosso do Sul America/Cuiaba Mato Grosso America/Porto_Velho W Para, Rondonia America/Boa_Vista Roraima IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 157
Code Time zone Comments America/Manaus E Amazonas America/Eirunepe W Amazonas America/Rio_Branco Acre America/Nassau Asia/Thimphu Africa/Gaborone Europe/Minsk America/Belize America/St_Johns Newfoundland Time, including SE Labrador America/Halifax Atlantic Time - Nova Scotia (most places), PEI America/Glace_Bay Atlantic Time - Nova Scotia - places that did not observe DST 1966-1971 America/Moncton Atlantic Time - New Brunswick...
Page 161
Code Time zone Comments Europe/Podgorica America/Marigot Indian/Antananarivo Pacific/Majuro most locations Pacific/Kwajalein Kwajalein Europe/Skopje Africa/Bamako Asia/Rangoon Asia/Ulaanbaatar most locations Asia/Hovd Bayan-Olgiy, Govi-Altai, Hovd, Uvs, Zavkhan Asia/Choibalsan Dornod, Sukhbaatar Asia/Macau Pacific/Saipan America/Martinique Africa/Nouakchott America/Montserrat Europe/Malta Indian/Mauritius Indian/Maldives Africa/Blantyre America/Mexico_City Central Time - most locations America/Cancun Central Time - Quintana Roo America/Merida...
Page 162
Moscow+04 - Yenisei River Asia/Irkutsk Moscow+05 - Lake Baikal Asia/Yakutsk Moscow+06 - Lena River Asia/Vladivostok Moscow+07 - Amur River Asia/Sakhalin Moscow+07 - Sakhalin Island Asia/Magadan Moscow+08 - Magadan Asia/Kamchatka Moscow+09 - Kamchatka IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 164
Alaska Time - Alaska panhandle America/Yakutat Alaska Time - Alaska panhandle neck America/Nome Alaska Time - west Alaska America/Adak Aleutian Islands Pacific/Honolulu Hawaii America/Montevideo Asia/Samarkand west Uzbekistan Asia/Tashkent east Uzbekistan Europe/Vatican America/St_Vincent America/Caracas America/Tortola America/St_Thomas IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 165
Code Time zone Comments Asia/Saigon Pacific/Efate Pacific/Wallis Pacific/Apia Asia/Aden Indian/Mayotte Africa/Johannesburg Africa/Lusaka Africa/Harare Appendix E. Worldwide time zone codes...
Page 166
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 168
(not nuttcp) in tests 2-5. Each of the first five tests below ran for 300 seconds (-t 300), while the last test monitored TCP performance during that time. Test 1: Latency This test checks the nominal network link latency and packet loss. Example result: IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 169
*** Latency PING 10.0.13.194 (10.0.13.194) 56(84) bytes of data. --- 10.0.13.194 ping statistics --- 120 packets transmitted, 120 received, 0% packet loss, time 119060ms rtt min/avg/max/mdev = 57.403/78.491/104.451/9.872 ms Interpreting the results: v The average round-trip-time (rtt) was 78.4ms and there was 0% packet loss. v The latency in WAN topologies may vary, but should never exceed 200ms.
Page 170
You may want to run these tests again to test the reverse throughput in the network. To run the tests in reverse, change server1 to the client and server2 to the server and repeat the procedures. IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
If you are not already logged in to the TSSC, log in with user ID service and password service. b. Right-click on the blue desktop, and from the IBM TS3000 System Console menu, select Browser Functions → SM GUI Functions → Launch GUI.
Page 172
If the storage firmware levels are 7.50.13.00 or higher (recommended level is 7.60.28.00), proceed to the ProtecTIER v. 2.4 upgrade. 2. Insert the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD into the TSSC drive. a. If you are not already logged in to the TSSC, log in with user ID service and password service.
Page 173
Windows 32-bit/DS4700. In the same window, click to highlight the FW.DS4700_07602800.dlp file from the Files section. Note: The storage system firmware is located on the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD under a 10.60.x5.17 for Windows 32-bit directory, DS4k Storage Manager v10.60.x5.17 for Windows 32-bit.
Page 174
Windows 32-bit/DS4700. In the same window click to highlight the esm98D0.esm file from the Files section. Note: The storage system firmware is located on the IBM System Storage ProtecTIER Manager V2.4.3.0 DVD under a 10.60.x5.17 for Windows 32-bit directory, DS4k Storage Manager v10.60.x5.17 for Windows 32-bit.
In the request, be sure to include the publication number and title. When you send information to IBM, you grant IBM a nonexclusive right to use or distribute the information in any way it believes appropriate without incurring any obligation to you.
Page 176
IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol ((R) or (TM)), these symbols indicate U.S.
A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at http://www.ibm.com/legal/copytrade.shtml. ® ® Adobe , the Adobe logo, PostScript , and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.
Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung der IBM gesteckt/eingebaut werden. EN 55022 Klasse A Geräte müssen mit folgendem Warnhinweis versehen werden: "Warnung: Dieses ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funk-Störungen verursachen;...
3F, No 7, Song Ren Rd., Taipei Taiwan Tel: 0800-016-888 Japan VCCI Council Class A statement Japan Electronics and Information Technology Industries Association (JEITA) Statement (less than or equal to 20 A per phase) IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 186
USB ports 9 TSSC configuring for use with the TS7650G 43 verifying systems attached to 57 verifying systems attached to TSSC 57 visual inspection indicators and fault LEDs 40 Web sites list xxxi IBM System Storage TS7600 with ProtecTIER: Installation Roadmap Guide...
Page 188
Part Number: 46X4265 Printed in USA GC53-1154-08...