CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 1 Functions Remote Control Self illuminating button OFF / ON I TEMP. Operation OFF / ON Room Temperature Setting Heating, Cooling, Soft Dry Operation. • Temperature Setting (16°C to 30°C) MODE Operation Mode Selection Automatic Operation •...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Indoor Unit AUTO OFF / ON Automatic Operation Button Indoor Fan Speed Control • Press for < 5s to operate Automatic • High, Medium and Low. operation mode. • Automatic Fan Speed Mode Heating : Fan speed varies from Me →...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Outdoor Unit CU-A18CTP5 CU-A12CTP5 CU-A24CTP5 Compressor Reverse Rotation Deice Control Protection Control • To prevent frosting at outdoor heat ex- changer. (Only for Heating Operation) • To protect compressor from reverse rotation when there is a instantaneous power failure.
Page 6
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Unit CS-A12CTP CU-A12CTP5 Heat Exchanger Description Evaporator Condenser Tube material Copper Copper Fin material Aluminium Aluminium (Blue Coated) Fin Type Louver Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft) 2 ×...
Page 8
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Unit CS-A18CTP CU-A18CTP5 Heat Exchanger Description Evaporator Condenser Tube material Copper Copper Fin material Aluminium Aluminium (Blue Coated) Fin Type Louver Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft) 2 ×...
Page 10
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Unit CS-A24CTP CU-A24CTP5 Heat Exchanger Description Evaporator Condenser Tube material Copper Copper Fin material Aluminium Aluminium (Blue Coated) Fin Type Louver Fin Corrugated Fin Row / Stage (Plate fin configuration, forced draft) 2 ×...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 7 Operation Details 7.1. Cooling Mode Operation Cooling in operation according to Remote Control setting. Time Delay Safety Control (3 minutes) • When the compressor is stopped by Remote Control, it restarts after 3 minutes when it is turned ON by Remote Control.
Page 20
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Compressor Protection Control • After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and restart automatically. (Time Delay Safety Control is valid).
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 7.2. Soft Dry Mode Operation • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start. • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 7.3. Heating Mode Operation Heating in operation according to Remote Control setting. Time Delay Safety Control • When the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON.
Page 25
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 4-way Valve Control • 4-way valve always ON during Heating operation. (Except Deicing operation) • When the unit is switched to “OFF” during Heating operation, 4-way valve stay at Heating position for 5 minutes.
Page 26
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Automatic Fan Speed Mode When Automatic Fan Speed is selected at Remote Control during heating operation. • Fan speed rotates in the range of Me → SLo according to the heat exchanger temperature.
Page 27
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Deicing Control 1) A12CT Deice starts to prevent frosting at outdoor heat exchanger. • Normal Deicing Deice operations detection commences after 30 minutes of Heating operation starts or 60 minutes after previous deice operation.
Page 28
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Normal Deicing Time Diagram Overload Deicing Time Diagram...
Page 29
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 2) A18CT, A24CT Deice starts to prevent frosting at outdoor heat exchanger. • Normal Deicing Deice operation detection commences in Heating operation starts or 60 minutes after previous deice operation. If the outdoor piping temperature drops to -4°C for 50 sec.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 (b) Overload Deicing Time Diagram 7.4. Automatic Mode Operation 1. When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for 25 seconds to sense intake air temperature and determine the 1st operation mode.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Heating Operation Purpose is to obtain a comfortable room temperature while sleeping. When you press the SLEEP Mode, the following movement will start to avoid overheating. • Sleep shift operation starts, when the room temperature reaches the setting temperature or after 1 hour of operation.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 7.9. Indoor Fan Speed Control Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on each operation as shown below.
Page 34
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 7.11. Soft starter (Applicable only for Australia market) A. Purpose To reduce starting current lower than 45A. B. Basic Operation (A18CTP, A24CTP) 1. When indoor relay is turn ON, starting capacitor will be turn ON through RY-C for ~ 1 second. After that reactor will be turn OFF through RY-L and in the same time RY-C will turn OFF causes starting capacitor to be OFF.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 8 Operating Instructions SAFETY PRECAUTIONS I Operation Precautions I Installation Precautions Before operating, please read the following “Safety Precautions” carefully. Warning Warning G To prevent personal injury, injury to others and This sign warns of death or serious injury.
Page 36
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 G How to Insert the Batteries NAME OF EACH PART I Remote Control 1 Signal Transmitter 2 Operation Display Cooling Model Gently press the place marked OPEN and slide the cover towards you.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 I Setting the Fan Speed G Automatic Operation • Press 4 to select:- • Press the Auto Airflow Direction Button 6. – Low Fan Speed I Setting the Horizontal Airflow Direction • Cooling / Soft Dry –...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 HELPFUL INFORMATION ENERGY SAVING AND OPERATION I Pre-season Inspection HINTS G Clean the air filters, re-insert and operate the air I Auto Operation conditioners. I Setting the Temperature • Approximately 10% of electricity can be saved.
Page 40
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 • When connecting the piping, do not not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials.
Page 41
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Attached accessories Indoor/Outdoor Unit Installation Diagram SELECT THE BEST LOCATION INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.2. INDOOR UNIT 9.2.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 9.2.2. HOW TO FIX INSTALLATION PARTS Installation on the ceiling • Measure and mark the position for the Suspension bolts and the piping hole.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.2.3. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING 1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.2.5. CONNECT THE CABLE TO THE INDOOR UNIT 1. Open the control box at the bottom end of the chassis and connect the cable through the hole. • Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.3. OUTDOOR UNIT 9.3.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 9.3.2. INSTALL THE OUTDOOR UNIT At the best location, start installation according to Indoor- Outdoor Unit Installation Diagram.
Page 46
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.3.4. (a) EVACUATION OF THE EQUIPMENT (FOR EUROPE & OCEANIA DESTINATION) WHEN INSTALLING AN AIR CONDITIONER, BE SURE TO EVACUATE THE AIR INSIDE THE INDOOR UNIT AND PIPES in the following procedure.
Page 47
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 2) Air Purging The air which contains a moisture is remaining in the Refrigeration cycle may cause a malfunction on the Compressor. 1. To purge the air, push the pin on the Gas side 3-way valve for three seconds using with a Hexagonal wrench and set it free for one minute.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 9.3.6. CONNECT THE CABLE TO THE OUTDOOR UNIT 1. Remove the control board cover from the unit by loosening the screw. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 3 x 1.5mm (C/V12CT) or 5 x 1.5mm...
Page 49
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 CHECK THE DRAINAGE • Connect the drain hose, as described below. • Pour water into the drain pan to ensure that water is drained smoothly through the drain hose. AUTO SWITCH OPERATION The below operations will be performed by pressing the “AUTO”...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 10 Servicing Information Caution: • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 11 Troubleshooting Guide 11.1. Refrigeration cycle system In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan.
Page 52
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 11.1.1. Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Heating Mode Condition of the air conditoner Low Pressure High Pressure Electric current Low Pressure High Pressure...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 15 Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 16 Replacement Parts List <Model: CU-A12CTP5> REF. NO. PART NAME & DESCRIPTION QTY. CU-A12CTP5 REMARKS CHASSY ASS’Y CWD50K2074 SOUND PROOF MATERIAL CWG302110 FAN MOTOR BRACKET CWD541030 SCREW - FAN MOTOR BRACKET CWH55413...
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 17 Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 69
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 How to use electronic circuit diagram...
Page 70
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 TIMER TABLE Test Mode Name Time (When test point Remarks Short-circuited) Real Timer 1 hr. 1 min. 10 min. 10 sec. 1 min. 1 sec. Time Delay Safety Control 2 min. 58 sec.