L300P Inverter Specifications
L300P Inverter Specifications
Tables for 200V
Note that "General Specifications" on page 1–9 covers all L300P inverters, followed by
footnotes for all specifications tables. Seven 200V models in the tables below (2 to 20 hp) have
class inverters
internal dynamic braking units (see "Dynamic Braking" on page 5–6).
L300P inverters, 200V models, UL ver.
Applicable motor size, 4-pole *2
Rated capacity (200/240V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
approximate (W)
Dynamic braking
approx. % torque,
short time stop *7
DC braking
Weight
L300P inverters, 200V models, UL ver.
Applicable motor size, 4-pole *2
Rated capacity (200/240V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
approximate (W)
Dynamic braking
approx. % torque,
short time stop *7
DC braking
Weight
Item
015LFU2
HP
2
kW
1.5
2.5 / 3.1
8.3
3-phase (3-wire) 200 to 240V (corresponding to input voltage)
7.5
92.3
at 70% output
102
at 100% output
125
without ext. res.
50%
with external res.
200%
Variable operating frequency, time, and braking force
kg / lb
3.5 / 7.7
Item
110LFU2
HP
15
kW
11
15.2 / 18.2
48
3-phase (3-wire) 200 to 240V (corresponding to input voltage)
44
94.8
at 70% output
435
at 100% output
600
without ext. res.
10%
with external res.
55%
with external res.
and braking unit
Variable operating frequency, time, and braking force
kg / lb
5 / 11
200V Class Specifications
022LFU2
037LFU2
055LFU2
3
5
2.2
3.7
3.6 / 4.3
5.7 / 6.8
8.3 / 9.9
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
12
18
10.5
16.5
93.2
94.0
127
179
160
235
20%
160%
100%
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
200V Class Specifications
150LFU2
185LFU2
220LFU2
20
25
15
18.5
20.0 / 24.1
25.2 / 30.3
29.4 / 35.3
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
64
80
58
73
94.9
95
575
698
800
975
10%
10%
50%
—
25–170%
25–150%
5 / 11
12 / 26.4
12 / 26.4
075LFU2
7.5
10
5.5
7.5
11 / 13.3
26
35
24
32
94.4
94.6
242
312
325
425
80%
5 / 11
300LFU2
30
40
22
30
39.1 / 46.9
94
124
85
113
95
95
820
1100
1150
1550
10%
10%
—
55–110%
12 / 26.4