Expand Serial Command Functional Specification Page 5 of 41 1. Overview 1.1. This Functional Specification defines communication functions such as Multi Card Imager for LV-7225/7220/5220. 1.2. The Projector Firmware Ver.1.x ready. 1.3. Commands are to communicate to such as Multi Card Imager, but most commands control a remote Projector with PC installed RS232C.
Expand Serial Command Functional Specification Page 6 of 41 3. Notes for Communication 3.1. The expand command is defined one command / one line that starts ”C” and ends carriage return (0x0D). 3.2. There are two types of command, functional execution commands and state read commands. Example of Functional Execution Command “CF_BRIGHT_032”...
Expand Serial Command Functional Specification Page 7 of 41 5. Functional Execution Command Table 5.1. Image Command Table Execute command Item CF_BRIGHT_%1 [CR] Set Brightness value CF_CONT_%1 [CR] Set Contrast value CF_COLOR_%1 [CR] Set Color value CF_TINT_%1 [CR] Set Tint value CF_SHARP_%1 [CR] Set Sharpness value CF_GAMMA_%1 [CR]...
Expand Serial Command Functional Specification Page 9 of 41 6. Status Read Command Table 6.1. Image Status Read Command Table Status read command Item CR_BRIGHT [CR] Read Brightness setting value CR_CONT [CR] Read Contrast setting value CR_COLOR [CR] Read Color setting value CR_TINT [CR] Read Tint setting value CR_SHARP [CR]...
Expand Serial Command Functional Specification Page 11 of 41 8. Functional Execution Command 8.1. Format The following format’s commands issued form a PC. Pattern 1: “CF_COMMAND” [CR] Pattern 2: “CF_COMMAND_” %1 [CR] CF_: Header COMMAND: Letters %1: Parameter (Letters) _: Space (To separate COMMAND and Parameter) When a projector decoded a received data and ready to receive the next Command, it will return acknowledgment.
Expand Serial Command Functional Specification Page 12 of 41 8.4. Image Command 8.4.1. CF_BRIGHT Command Command “CF”_BRIGHT_%1” [CR] “000 – 063” ----------- Directly select the Bright setting value “UP” -------------------- Bright setting value +1 “DN” -------------------- Bright setting value -1 Set the user control Bright value.
Expand Serial Command Functional Specification Page 13 of 41 8.4.5. CF_SHARP Command Command “CF_SHARP_%1” [CR] “000 – 015” ------------ Directly select the Sharpness setting value “UP” --------------------- Sharpness setting value +1 “DN” --------------------- Sharpness setting value -1 Set the user control Sharpness value. The value set by the command will not be saved to the Projector.
Expand Serial Command Functional Specification Page 14 of 41 8.4.9 CF_PROGV Command Command “CF_PROGV_%1” [CR] “L1” ------------- Select Progressive Mode L1 “L2” ------------- Select Progressive Mode L2 “OFF” ---------- Cancel Progressive Set / Cancel for Progressive. The value set by the command will not be saved to the Projector. Details Therefore, when AC Power Off the Projector, the value will return to the original setting.
Expand Serial Command Functional Specification Page 15 of 41 8.5. PC Control Command 8.5.1. CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000 – 0031” --------- Directly set Fine Sync setting value “UP” --------------------- Fine Sync setting value +1 “DN” --------------------- Fine Sync setting value -1 Set Fine Sync for PC signal.
Expand Serial Command Functional Specification Page 16 of 41 8.5.5. CF_V-POS Command Command “CF_V-POS_%1” [CR] “0000 – nnnn” ----------- Directly set Vertical Position setting value “nnnn” is maximum value. This is current Total Line value - Display Line value. “UP” ---------------------- Vertical Position setting value +1 “DN”...
Expand Serial Command Functional Specification Page 17 of 41 8.5.8. CF_PCSTORE Command Command “CF_PCSTORE”_%1” [CR] “MODE1” ------------ Store current PC Adjust status to Mode 1 “MODE2” ------------ Store current PC Adjust status to Mode 2 “MODE3” ------------ Store current PC Adjust status to Mode 3 “MODE4”...
Expand Serial Command Functional Specification Page 18 of 41 8.6.3. CF_AVHPOS Command Command “CF_AVHPOS_%1” [CR] “UP” ------------ Current setting value +1 “DN” ------------ Current setting value –1 Set AV Service Mode Horizontal Position value. (Only valid when it is in the usual Power On status) Details This setting status is stored in EEPROM, hold even if AC Power turning Off and On.
Expand Serial Command Functional Specification Page 21 of 41 8.8.2. CF_FLSCREN Command Command “CF_FLSCREN_%1” [CR] “ON” ------------- Select Full Screen “OFF” ------------ Cancel Full Screen Set / Cancel Full Screen. (Only valid when it is in the usual Power On status) PC Input The value set by this Command will not be saved to the Projector.
Expand Serial Command Functional Specification Page 22 of 41 8.8.6. CF_KYSTNMODE Command Command “CF_KYSTNMODE_%1” [CR] “STR” ----------- Set Keystone store Mode to Store “RST” ----------- Set Keystone store Mode to Reset Details Set Keystone store Mode. (Only valid when it is in the usual Power On status) Acceptable “000”...
Expand Serial Command Functional Specification Page 23 of 41 8.10.2. CF_MUTE Command Command “CF_MUTE_%1” [CR] “ON” --------- Sound Mute On “OFF” -- ----- Sound Mute Off Details Control Sound Mute On/Off. (Only valid when it is in the usual Power On status) Acceptable “000”...
Expand Serial Command Functional Specification Page 24 of 41 8.11.5. CF_REAR Command Command “CF_REAR_%1” [CR] “ON” ---------- Select Rear “OFF” --------- Cancel Rear Set / Cancel Rear. (Only valid when it is in the usual Power On status) Details When Rear is On, it will be a mirror-reversed image. This setting status is stored in EEPROM, hold even if AC Power turning Off and On.
Expand Serial Command Functional Specification Page 25 of 41 8.11.9. CF_P-MANE Command Command “CF_P-MANE_%1” [CR] “ O F F ” - - - - - - - - - - - - - - - Set Power Management to Off “...
Expand Serial Command Functional Specification Page 26 of 41 8.11.14. CF_STANDBYMODE Command Command “CF_STANDBYMODE_%1” [CR] “ECO” ------------ Standby power requirement is smaller “NORMAL” ----- Normal Standby power requirement Details Set Standby mode. (Only valid when it is in the usual Power On status) Acceptable “000”...
Expand Serial Command Functional Specification Page 27 of 41 8.11.18. CF_LOGOCAPTURE Command Command “CF_LOGOCAPTURE_%1” [CR] “START” ------------ Capture On Capture the current image on screen. When beginning to capture the image, any command is not available until the Details capture has done. When sending the command during the process, the Projector returns the error code, “301”.
Expand Serial Command Functional Specification Page 28 of 41 9. Status Read Command 9.1. Format PC issues Commands as below “CR_COMMAND” [CR] COMMAND: Character Line When Projector receives the appropriate Command, it returns a character line as the required data. “000_%1”...
Expand Serial Command Functional Specification Page 31 of 41 9.5. PC Status Read Command 9.5.1. CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get Fine Sync value Acceptable “000_%a” [CR] “0000” – “0031” Response “Error code” [CR] ---- Invalid Unacceptable “?” [CR] ---------- When the Projector received unclear command 9.5.2.
Expand Serial Command Functional Specification Page 33 of 41 9.6. Video Status Read Command 9.6.1. CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected signal. Details When Auto Mode, it returns by Auto-detect. Only available when Input-Video. (Unavailable when Input is Computer) Acceptable “000_%a”...
Expand Serial Command Functional Specification Page 36 of 41 9.9. Lamp Status Read Command 9.9.1. CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get Lamp replacement time information Acceptable “000_%a” [CR] “1Y” ------- Over the Lamp replacement time Response “1N” ------- Have not reached the lamp replacement time Unacceptable “?”...
Expand Serial Command Functional Specification Page 37 of 41 9.11. Setting Status Read Command 9.11.1. CR_BBACK Command Command “CR_BBACK” [CR] Details Get Blue Back setting Acceptable “000_%a” [CR] “ON” --------- Set Blue Back Response “OFF” ------- Cancel Blue Back Unacceptable “?”...
Expand Serial Command Functional Specification Page 38 of 41 9.11.5. CR_LANG Command Command “CR_LANG” [CR] Details Get selected Language Acceptable “000_%a” [CR] “ENG” --------- English is selected “DEU” --------- German is selected “FRA” --------- French is selected “ITA” ---------- Italian is selected “ESP”...
Expand Serial Command Functional Specification Page 40 of 41 9.11.14. CR_AUTOSETUP Command Command “CR_AUTOSETUP_%1” [CR] “KEYSTONE” --------- Specify Auto Keystone “PCADJ” ---------------- Specify Auto PC Adj. Details Get Auto Setup setting status Acceptable “000_%a” [CR] When Keystone “AUTO” ----------- Auto setting “MANUAL”...