Page 1
Dell™ PowerVault™ 51F 8-Port Fibre Channel Switch INSTALLATION AND TROUBLESHOOTING GUIDE B E D IR E C T ™ ™ www.dell.com...
Page 2
Reproduction in any manner whatsoever without the written permission of Dell Computer Corporation is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, Dell OpenManage, PowerVault, PowerEdge, Dimension, Inspiron, OptiPlex, Latitude, and DellWare are trademarks of Dell Computer Corporation; Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation;...
Only trained service technicians are authorized to remove the computer covers and access any of the components inside the computer. This warning applies to Dell PowerEdge 4xxx or higher servers and Dell PowerVault 2xxS storage systems.
Observe the following general precautions for using and working with your system: • Observe and follow service markings. Do not service any Dell product except as explained in your Dell system documentation. Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to electrical shock.
Page 5
Use the correct external power source. Operate the product only from the type of power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your Dell service provider or local power company.
Page 6
80 percent of the extension cable or power strip ampere ratings limit. • Do not use appliance/voltage converters or kits sold for appliances with your Dell product. • To help protect your system components from sudden, transient increases and decreases in electrical power, use a surge suppressor, line conditioner, or un- interruptible power supply (UPS).
Page 7
• System rack kits are intended to be installed in a Dell rack by trained service tech- nicians. If you install the kit in any other rack, be sure that the rack meets the specifications of a Dell rack.
Page 8
Before you remove the computer covers, perform the following steps in the sequence indicated. NOTICE: Some Dell systems can be serviced only by trained service techni- cians because of high voltages and energy hazards. Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Dell documentation.
NOTICE: To help avoid possible damage to the system board, wait 5 sec- onds after turning off the system before removing a component from the system board or disconnecting a peripheral device from the computer. Turn off your computer and any devices. Ground yourself by touching an unpainted metal surface on the chassis, such as the metal around the card-slot openings at the back of the computer, before touching anything inside your computer.
Page 10
• Position your system so that the monitor and keyboard are directly in front of you as you work. Special shelves are available (from Dell and other sources) to help you correctly position your keyboard. •...
Page 11
Monitor screen at or below eye level Wrists relaxed and flat Arms at desk level Feet flat on the floor Monitor and keyboard positioned directly in front of user xiii...
Preface About This Guide This guide is intended for anyone who is installing and managing a Dell PowerVault 51F 8-Port Fibre Channel Switch. It is to be used by field technicians, hardware and software engineers, and system administrators for monitoring and troubleshooting the switch.
Besides this Installation and Troubleshooting Guide, the following documentation is included with your system: • The Dell PowerVault 51F 8-Port Fibre Channel Switch User’s Guide introduces the user to the PowerVault 51F and includes feature information and specifications. • The Dell PowerVault Switch Manager User’s Guide describes the Dell PowerVault Switch Manager and how to use each of its funtions.
Page 15
• Syntax lines consist of a command and all its possible parameters. Commands are displayed in lowercase bold; variable parameters (those for which you substitute a value) are displayed in lowercase italics; constant parameters are dis- played in lowercase bold. The brackets indicate items that are optional. Example: del [drive:] [path] filename [/p] •...
C H A P T E R 1 Installing the Dell™ PowerVault™ 51F Switch The complete setup for the Dell PowerVault 51F switch includes: • Unpacking the switch • Selecting a location and mounting method • Setting up connections •...
NOTE: The switch meets International Electronic Commission (IEC) 801-5 surge volt- age requirements; however, there is no other provision for surge protection built into the switch’s power supplies. An installation should include normal provisions to assure clean power. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Press the GBIC module until its connector is firmly seated. Rack Mounting This section provides instructions for trained service technicians installing one or more Dell PowerVault 51F switches in a Dell rack. The switch rack-mounting hardware (see Figure 1-2) includes: •...
Prepare the switch for mounting. Install the outer slides. Install the switch assembly in the rack. Install the cable-management arm and route the cables. Replace the rack doors if you removed them. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Open the latch on the front door (see Figure 1-3). Slide the latch’s push-button cover up as far as it will go, press the push button, rotate the handle clockwise until the latch releases, and then pull the door open. support.dell.com Installing the Dell PowerVault 51F Switch...
The person holding the top of the door should press the hinge release lever on the top hinge and then pull the door away from the rack. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Remove the foam spacer by gently pulling upward on the strap marked “Remove Before Use.” Be sure that no bits of foam remain in the manifold and that the gaskets were not damaged during extraction of the foam spacer. support.dell.com Installing the Dell PowerVault 51F Switch...
Adjusting the Bezel Position If you are installing the switch in a non-Dell rack, you may need to adjust the bezel position to allow the rack doors to close properly. To adjust the bezel position, perform the following steps: Remove the screws and mounting clip from one side of the bezel (see Figure 1-5).
Fully tighten the screws and then back them out about two turns. Leaving the outer slides loose makes it easier to align the outer slides and the inner-slide rails. support.dell.com Installing the Dell PowerVault 51F Switch...
Tighten the thumbscrews on the bezel to keep the switch and slide assembly from sliding out of the rack. The thumbscrews pass through the holes in the rack and into the middle holes of the stationary brackets. 1-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
T-tabs into the two T- slots until the retaining clip snaps into place (see Figure 1-8). T-slots cable-management arm inner rail Velcro strips thumbscrew T-tabs retaining clip safety release latch Figure 1-8. Installing the Cable-Management Arm support.dell.com Installing the Dell PowerVault 51F Switch 1-11...
Firmly press the rubber feet in place. NOTE: If rubber feet have been installed, they must be removed before the unit can be installed in a 19-inch rack. 1-12 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
(I/O) Various lengths of copper and optical cables are available from Dell. These cables have been designed and approved by Dell. Dell recommends the use of these cables to ensure the proper operation of the PowerVault 51F system. Fiber cable connections are made to the switch’s front panel using standard dual SC plug connectors as shown in Figure 1-9.
The serial port settings are as follows: • 8 bit • No parity • One stop bit • 9600 baud • HyperTerminal 1-14 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
NOTICE: The serial port is intended for initial configuration of the IP address or disaster recovery only and not for regular maintenance. Dell recommends removing the serial port cable for normal (non-configuration, non-recovery) switch operation.
If an amber GBIC module light is displayed, there was a failure on that port during POST . See “Power-On Diagnostics” in Chapter 5 for more information. 1-16 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
As the admin user, type ipAddrSet and press <Enter>. The following text appears: Ethernet IP Address [current address shown]: [enter new address if needed] Ethernet Subnetmaks [current]: [enter new subnet mask if needed] Fibre Channel IP Address [current]: [enter new address if needed] support.dell.com Installing the Dell PowerVault 51F Switch 1-17...
The configDefault command does not affect the SNMP agent configuration. To reset SNMP agent configuration, use the agtcfgDefault command. See Chapter 4, “PowerVault 51F Commands,” for help on using commands. 1-18 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The cost should not exceed 7000 (7 x 1000). A fabric using Dell switches in cascaded topologies should be configured to deliver the required bandwidth and fault tolerance with all connections made within the seven-hop maximum limit.
The PowerVault 51F switch runs on version 2.0 of the software only. To be compatible with PowerVault 50F software, the PowerVault 51F system must be configured using VC Encoded Address Mode, which limits the switch count in a fabric to 32 and the number of multicast groups to 31.
NOTE: After a path has been determined, it is not rerouted, even though traffic vol- ume may change over time, for each path to maintain in-order delivery. If the link fails, the path is rerouted. DELL CONFIDENTIAL - Preliminary 4/6/00 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Increasing bandwidth between switches is done by adding additional connections between the switches. In addition to the bandwidth, redundant connections between the switches in Figure 2-2 provide a high-bandwidth, fault-tolerant fabric. DELL CONFIDENTIAL - Preliminary 4/6/00 support.dell.com PowerVault 51F Topologies...
Hardware Dell OpenManage version 2.0 software executes on the PowerVault 51F system only. However, PowerVault 51F switches and PowerVault 50F switches can share the same fabric by configuring version 2.0 into a specific addressing mode designated as VC Encoded Address Mode. Invoking this mode is described under the configure com- mand described in Chapter 4.
Figure 3-1 shows the various methods and communication paths for accessing switch management information. NOTE: Dell recommends the switch be managed remotely using Telnet or Web man- agement (PowerVault Switch Manager). Dell recommends the serial port be used only to initially configure the switch and that the RS-232 serial communications cable be removed after initial configuration.
Telnet session is completed but re-logging in is required. A password is required to log in to the serial port session. Password checking is skipped only at initial power on and remains off until log off is done. support.dell.com Managing the PowerVault 51F Switch...
Enter a password or name while a username is displayed to replace the existing password or name. NOTE: If you lose the password, contact Dell for technical assistance. Managing With SNMP Under Dell OpenManage NOTICE: SNMP settings on the switch pose a security risk.
Dell recommends that you use one of the “ro” communities to set up your trap community and trap recipients IP address. Also, the administrator of the switch may want to rename the default communities to a unique secure name. The resident SNMP manage node allows remote switch management via IP over Ethernet and Fibre Channel interfaces.
— Indicates the manage node has received a protocol mes- sage that is not properly authenticated. This trap, by default, is disabled but can be enabled via the command agtcfgSet. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
SNMP trap, swEventTrap, is sent to configured recipi- ents. By default, this value is set at 0, implying that no swEventTrap is sent. Possible values are as follows: 0 — None 1 — Critical support.dell.com Managing the PowerVault 51F Switch...
The PowerVault Switch Manager also provides access to all zoning functions. For more information about the PowerVault Switch Manager see the Dell PowerVault Switch Manager User’s Guide. support.dell.com...
- Scroll forward through previous commands j or + Insert text after cursor Insert text before cursor Insert text at end of current line Delete entire line Delete from cursor to end of line support.dell.com PowerVault 51F Commands...
SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) No trap recipient configured yet Community 2: OrigEquipMfr (rw) No trap recipient configured yet Community 3: private (rw) No trap recipient configured yet Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
In the context of SNMPv1 and SNMPv2c, this means that a request that contains a community string is not known to the agent. The default value for this parameter is 0 (disabled). support.dell.com PowerVault 51F Commands...
HP OpenView Network Node Man- ager Special Edition (NNM SE) 3.0 and later have management information base (MIB) and autodiscovery support for the switch. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Otherwise, it shows the user the number of alias group entries created with the title: The Local Alias Server has n entries Alias ID Creator Token [rb, type, grptype, qlfr] Member List support.dell.com PowerVault 51F Commands...
(shown in brackets). The current value is used in the absence of an entered value when a carriage return is the only input Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The configure command may be canceled at any time by sending an interrupt control character by pressing <Ctrl> <c>. In addition, the command may be completed at any time, with the current changes saved, by sending an end-of-file control character by pressing <Ctrl><d>. support.dell.com PowerVault 51F Commands...
Name Server will not be present in the Name Server data Probing base. Set this mode only if the switch's N_Port discovery pro- cess (PLOGI, PRLI, INQUIRY) causes some attached device to fail. 4-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Field Description VC Encoded When this mode is set, frame source and destination addresses Address utilize an address format compatible with PowerVault 50F Mode system. When this mode is set to 0, 239 PowerVault 51F switches may be cascaded. Disable Trans-...
RSCN will always be issued fol- lowing the completion of loop initialization, regardless of the presence or absence of new or preexisting devices. 4-12 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
On most UNIX-based systems (HP-UX, Irix, Linux, Solaris, and so on) the commands to retrieve the information are rup and rsysinfo. Please see your local system documentation for the appropriate usage of the rup, rsysinfo, or equivalent commands. support.dell.com PowerVault 51F Commands 4-13...
The date command displays the system date and time. To set the date, perform the following steps: Type date followed by the date in the order of where: mmddHHMMyy is the month is the date is the hour 4-14 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The diagHelp command displays the diagnostic help commands available for trouble- shooting switch problems. These commands should be run only as advised by Dell technical support. The following example shows the information that appears when the command is run switch:admin>...
— If there is more than one occurrence of an error type, the number of occur- rences is shown in brackets following the error date and time. The following is an example of the errShow command screen. 4-16 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The switch's domain ID (1 to 239) • The switch's embedded port ID • The switch's World Wide Name • The switch’s Ethernet and IP addresses • The switch's symbolic name (a “>” indicates the principal switch in the fabric) support.dell.com PowerVault 51F Commands 4-17...
UNIX host, no special software is needed. For Windows 95 or Windows NT host, the Dell PowerVault system utilities diskette provides a daemon to support a remote shell (RSH). A firmware download is executed via an RCP command running on top of Transmission Control Protocol (TCP) between the switch and the host.
Click Start and then click Programs. In the program list, click Dell OpenManage PowerVault Manager, then click PowerVault 51F Utilities, and then click rshd. The remote shell daemon starts. The cat.exe is run from the rshd.exe file Start a Telnet session to a switch by typing the following command:...
Dead — Task no longer exists Program counter Stack pointer ERRNO Last error number generated by this task Delay For pending tasks, the amount of time a task has been waiting to execute 4-20 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The Fibre Channel subnetmask for the switch. The subnetmask default is none. Gateway IP address The gateway IP address. The default gateway address on a new switch is none. You must enter a valid gate- way address, if required. support.dell.com PowerVault 51F Commands 4-21...
FC-PH type. The possible values for FC4Type are: • 5 - FC-IP • 8 - SCSI-FCP For example, nsAllShow shows all SCSI-FCP nodes. If the parameter is not pro- vided, then all Nx_Ports are displayed. 4-22 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Note also that a cached entry would have an '*' at the beginning. NOTE: Only local entries are displayed. passwd The passwd command is used to set user names and passwords. The command syntax is passwd [ "user name" ]. support.dell.com PowerVault 51F Commands 4-23...
Table 4-14. The command syntax is portStatsShow <port#> . Table 4-14. portStatsShow Command Field Descriptions Field Description stat_wtx Number of 4-byte words transmitted from the port. stat_wrx Number of 4-byte words received by the port. support.dell.com PowerVault 51F Commands 4-25...
Page 88
This quantity could increment at times during nor- mal operation but might be used for diagnosing problems in some situations. 4-26 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
After the status line, a power supply identification line may be shown. If present, this line contains manufacture date, part numbers, serial numbers, and other information. support.dell.com PowerVault 51F Commands 4-27...
The switchName command displays the name of the current switch. By supplying an argument, the user may set the name of the current switch. NOTE: This command is only available to admin-level users. 4-28 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The GBIC type follows the port number. The five GBIC types include: -- — No GBIC present — Shortwave GBIC — Longwave GBIC — Copper GBIC — Serial ID 4-30 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The syslogdIp command sets or displays the switches system log daemon IP address. The command syntax is syslogdip < ip address >. tempShow The following example shows the tempShow command screen, which shows the switch’s temperature as measured by five sensors on the system board. support.dell.com PowerVault 51F Commands 4-31...
The build date of the firmware stored in flash memory BootProm The build date of the firmware stored in the boot PROM License Commands License commands are reserved for use by Dell only. 4-32 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
For instance, the bitmap value 0x00010003 means that port 0, port 1 and port 16 (the embedded port) are members of the set. switch:admin> bcastShow Group Member Ports Member ISL Ports Static ISL Ports ---------------------------------------------------------------- 0x00000100 0x00000000 0x00000000 support.dell.com PowerVault 51F Commands 4-33...
The current neighbor state. Its value must be NB_ST_FULL for the ISL to forward frames to the adjacent switch. Other values may be transitory, however if a value is retained for more than ten seconds, contact Dell for technical assistance. nghbP Neighbor capabilities has a value of 0.
The current version is 1 and there is no version 0. nHloIn The number of Hello frames received from the neighbor switch. nInvHlo The number of Hello frames with invalid parameters received from the neighbor switch. 4-36 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Use this command only if there are devices connected to the fabric that do not tolerate occasional out-of-order delivery of frames. The default behavior is for the in-order delivery option to be off. support.dell.com PowerVault 51F Commands 4-37...
1. length The total record length. chksum The record checksum. It includes all fields except lsAge. 4-38 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The command syntax is nbrStateShow <port number> to list the neighbor on the specified port. Table 4-23. nbrStateShow Command Field Descriptions Field Description Local Port Corresponds to idbNo in the neighbor data structure. Domain Corresponds to nghbId in the neighbor data structure. support.dell.com PowerVault 51F Commands 4-39...
The FSPF protocol supports equal cost multipaths, so there could be multiple parallel paths between two switches. The command syntax is topologyShow to list all domains. The command syntax is topologyShow < domain ID > to list the specified domain. 4-40 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
D unless a static path is configured. The following example shows the uRouteConfig command screen: switch:admin>uRouteConfig 2,2,4 committing configuration...done. uRouteRemove The uRouteRemove command removes the previous static route configuration, as shown in the following example: switch:admin>uRouteRemove <PORT>, <DOMAIN> support.dell.com PowerVault 51F Commands 4-41...
If any port fails during a diagnostic test, it is marked BAD in the status display and is ignored (not tried) until the system is rebooted. support.dell.com Troubleshooting...
G_Port interface cards. Front-Panel LED Power Indicators The color and flash speed of the power LED, as described in Table 5-1, indicates the switch’s status. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Preliminary POST diagnostics. VxWorks operating system initialization. Hardware initialization (resets, internal addresses assigned to G_Port and FL_Port ASICs, serial port initialized, front panel initialized). Full POST. Universal port configuration. Link initialization; receiver/transmitter negotiation to bring connected ports online. support.dell.com Troubleshooting...
NOTE: A switch boot failure indicates the switch must be taken off-line to be either repaired or replaced. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Only trained service technicians are authorized to remove the computer covers and access any of the components inside the computer. This warning applies to Dell PowerEdge 4xxx or higher servers and Dell PowerVault 2xxS storage systems. WARNING: This system may have more than one power supply cable. To reduce the risk of electrical shock, a trained service technician must discon- nect all power supply cables before servicing the system.
Reattach external cabling to the power supply. The switch automatically runs power-on self-test (POST) on a 2401 switch because all the power was off. Check for error messages via Telnet. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
The latch prongs will lock and prevent the GBIC’s accidental removal. NOTE: The GBIC module is keyed so it can be inserted in only one way. Do not force the insertion if the module does not slide in easily. support.dell.com Repair and Replacement...
Unscrew the two captive screws at the back of the unit by turning them a quarter turn to the left. See Figure 6-4. Slide the cover at least one 1/2-inch back from the front of the unit. Lift the cover off. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Tilt the assembly slightly up and slide it onto the two metal slats protruding from the back of the chassis. Move aside the power supply wiring harnesses, lower the assembly onto the metal tabs protruding from the back of the power supply chassis. support.dell.com Repair and Replacement...
(See Figure 6-6.) Lift the back end of the system board at a 45-degree angle up over the metal guides and slide it back until it lifts out of the chassis. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
1 on the connector. Gently lay the excess ribbon cable between the system board and chassis to prevent cable damage. Reconnect the power supply connector(s). Reconnect the fan tray assembly connector. Replace the switch’s cover. support.dell.com Repair and Replacement...
See “Removing the System Board,” found earlier in this chapter for instructions. 10. Remove the fan tray assembly. See “Removing the Fan Assembly,” found earlier in this chapter for instructions. Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Install the power supply(s). See “Installing a Power Supply,” found earlier in this chapter for instructions. Reconnect all external cabling. Turn on the switch’s power. The switch automatically runs POST . 10. Check for error messages via Telnet. support.dell.com Repair and Replacement...
C H A P T E R 7 Getting Help This chapter describes the tools Dell provides to help you when you have a problem with your system. It also tells you when and how to call Dell for technical or customer assistance. Technical Assistance If you need assistance with a technical problem, perform the following steps: Run the Dell Diagnostics.
Help Tools Dell provides a number of tools to assist you. These tools are described in the follow- ing sections. NOTE: Some of the following tools are not always available in all locations outside the continental U.S. Please call your local Dell representative for information on availability.
TechFax Service Dell takes full advantage of fax technology to serve you better. Twenty-four hours a day, seven days a week, you can call the Dell TechFax line toll-free for all kinds of tech- nical information. Using a touch-tone phone, you can select from a full directory of topics. The technical information you request is sent within minutes to the fax number you designate.
If you need information about additional products available from Dell Computer Corpo- ration, or if you would like to place an order, visit Dell’s World Wide Web site at http://www.dell.com/. For the telephone number to call to speak to a sales special- ist, refer to “Dell Contact Numbers”...
Remember to fill out the Diagnostics Checklist (Figure 7-1). If possible, turn on your system before you call Dell for technical assistance and call from a telephone at or near the computer. You may be asked to type some commands at the keyboard, relay detailed information during operations, or try other troubleshooting steps possible only at the system itself.
Name: ______________________________________________________________Date: ______________________ Address: ________________________________________________________Phone number: _________________ Service tag (bar code on the back of the computer): _________________________________________________ Express Service Code: ___________________________________________________________________________ Return Material Authorization Number (if provided by Dell support technician): ___________________________ Operating system and version: ____________________________________________________________________ Peripherals: ____________________________________________________________________________________ _______________________________________________________________________________________________...
Dell Contact Numbers When you need to contact Dell, use the telephone numbers, codes, and electronic addresses provided in Tables 7-1 and 7-2. Table 7-1 provides the various codes required to make long-distance and international calls. Table 7-2 provides local tele-...
— Macau — Not required Malaysia (Penang) Mexico (Colonia Granada) Netherlands (Amsterdam) New Zealand — Norway (Lysaker) Not required Poland (Warsaw) Singapore (Singapore) Not required South Africa (Johannesburg) 09/091 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
Taiwan — Thailand — U.K. (Bracknell) 1344 U.S.A. (Austin, Texas) Not required Table 7-2. Dell Contact Numbers Area Local Number or Department Name or Service Code Toll-Free Number Country (City) Australia Home and Small Business ....... . . 1-300-65-55-33 (Sydney) Government and Business .
Page 128
Sales, Customer Support, and Technical Support ..toll free: 1230-020-4823 Chile (Santiago) NOTE: Customers in Chile call the U.S.A for sales, cus- tomer, and technical assistance. 7-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...
NOTE: The error counter goes to a maximum of 999. The display halts after each error is displayed, prompting you to either press <Enter> to continue or type a to quit. Continue pressing <Enter> until the prompt => is displayed. support.dell.com Error Messages...
=> errShow Error 02 -------- 0x103dc470 (tSilkworm): Apr 9 10:41:06 Error SENSOR-FAILED, 3, sensor 7 (Fan 2) is below minim Type <CR> to continue, Q<CR> to stop: Error 01 -------- 0x103dc470 (tSilkworm): Apr 9 10:40:51 Error DIAG-TIMEOUT, 1, Port 2 receive timeout. Type <CR>...
Page 141
Check the protocol version col version run- on both switches using the ning on the local fspfShow command. If the switch is lower two versions differ, update than a neighbor’s the software on the local switch. switch. support.dell.com Error Messages...
Page 142
Table A-1. Errors (continued) Error Module Severity Explanation Action INVHLO (1) The path selec- Check that all paths and tion task has routing tables are correct. If received a they are not, reboot the HELLO message neighbor switch. with an invalid Check the paths and routes parameter from a again.
Page 143
SYSCALL (2) A system call into Reboot the switch. Contact VxWorks failed. customer support. TIMERS ENQFAIL (1) An error occurred Reboot the switch. Run the while setting a commands timer. actTimersShow and timerShow <timer ID>. Contact customer support. support.dell.com Error Messages...
Table A-1. Errors (continued) Error Module Severity Explanation Action MSG (3) The timer task Contact customer support. received an unknown message. Panic Errors This module includes errors that cause a system panic to occur. A system panic causes the switch to reboot. The PANIC error is stored in flash memory with a stack trace, local stack content and local register content at the time the error occurred.
These problems can be diagnosed by technical support provided enough information is collected to allow a detailed analysis of the specific case. The MQ-QWRITE error message is shown in Figure A-2 (the front panel displays an abridged version of the message). support.dell.com Error Messages...
Dell_FC_Switch# 0x103fce60 (tTimers): Oct 14 11:07:43 Error MQ-QWRITE, 1, mqWrite failed, queue = 0x103d1d20, msg = 0x103fd3d0, errno = 0x3d0002 Traceback: _mqWrite+0x44 (0x10065864) _mPathAllShow+0x1158 (0x10078498) Figure A-2. MQ-QWRITE Error Example The most notable parameters are: • The ID of the task that attempted to send the message ( tTimers in Figure A-2) •...
Stops microprocessor utilization monitoring. This spyStop command can be typed in at any time during the monitoring process. For information on executing these commands, contact Dell for technical assistance. Other Possible Errors This section explains the other errors that may occur. Fan Error Message Fan has stopped spinning: Please check the fans inside the switch box.
Diag_Flt: the port failed diagnostics (defective G_Port card or motherboard) Port is OK (Solid Green LED): The port is online and connected to a device over the cable. Port is segmented (Slow Flashing Green LED): Port is online but segmented. Please check for loopback cable or incompatible switch.
Class 2 connections. A fabric is an active, intelli- gent, nonshared interconnect scheme for In Class-2 service, the fabric and destina- nodes. tion N_Port provide connectionless service with notification of delivery or non- delivery between the two N_Ports. support.dell.com Glossary...
Page 150
R_A_TOV is used to time out operations that depend on the maximum possible time that a frame could be delayed in a fabric and still be delivered. The value of R_A_TOV is adjustable in 1-microsecond Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide...