Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
REFER TO INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1.
INTRODUCTION
AP3R Particulate filter provides protection against solid particles and water based aerosols. Suitable for
use with the Sealey 9000 half face mask. Conforms to EN 143:2000. Maximum filtration levels 30 x OEL
Type Examination Ref.:
Notified Body:
PIB) (notified body number 1437)
2.
FILTER PROTECTION
T-B filters of class P2 (P3) when completed with an appropriate two-filter face part (half mask, mask) protect the respiratory system
against non-toxic and moderately toxic (P3 - toxic) solid aerosols or water-based aerosols (dust, smoke) and liquid aerosols (mists),
provided that the concentration of the dispersed phase of the aerosol does not exceed the value of 12 x NDS (P3 - 50 x NDS) when
completed with a half mask, and 16.5 x NDS (P3 – 1000 x NDS) when completed with a mask. The P2 (P3) filter with carbon fleece
additionally protects against odours and unpleasant odours as well as the irritating effects of aerosols and organic vapours. This makes
it possible to use protective equipment equipped with T-B P2 (P3) R-A filters in an atmosphere contaminated with organic substances,
provided that their concentration does not exceed the MRL value.
P2 - Penetration: < 3%, P3 - Penetration: < 0.05%
P2 - Breathing resistance (47.5 l/min.): < 160 Pa, P3 - Breathing resistance (47.5 l/min.): < 260 Pa
MARKS
MEANING
A
Filter against organic gases and vapours with a
boiling point > 65⁰C
AX
Filter against filter against organic gases and
vapours with a boiling point < 65⁰C
B
Filter against inorganic gases and vapors
excluding carbon monoxide
E
Filter against sulfur dioxide and other acid gases
K
Filter against ammonia and organic vapours
derived from ammonia
P
Filter against particulate (dust and aerosols)
R
Filter reusable
NR
Filter non reusable
D
Filter passes the optional Dolomite clogging test
2.1.
P2 and P3 grade T-B filters are manufactured with three types of bayonet connectors. To distinguish
the type of connector, the filters have appropriate extensions in the name, namely:
2.1.1. VENT ESKA T-B P2 (P3) R and T-B P2 (P3) R-A filters have a bayonet connector that allows them to
be mounted with half masks: SECURA 2000, Advantage 200, 300, 400 and masks: Advantage 1000, 3000 or MAG-2
2.1.2. VENT ELKA T-BL P2 (P3) R and T-BL A P2 (P3) R filters have a bayonet connector that allows them to be mounted with half masks or
masks with BLS connectors
2.1.3. The VENT EMKA T-BM P2 (P3) R and T-BM A P2 (P3) R filters have a bayonet connector that allows them to be mounted with half
masks or masks with a bayonet connector, such as those from 3M
The use of T-B filters with other facepieces requires checking the compatibility of their bayonet connector with the filter connector.
2.2.
Respirators and masks should be adjusted to the user's face before use in accordance with the instructions for use of the protective
equipment in question.
2.3.
Assess whether the filters meet the requirements for existing hazards
2.4.
Respirators and masks with T-B filters of class P2 (P3) do not protect against carbon monoxide. Do not use half masks and masks with
filters in the area of fires.
2.5.
Half masks and masks with T-B filters of class P2 (P3) should not be used where oxygen deficiency (below 19% vol.) may occur, e.g. in
manholes, ducts, unventilated rooms with small cubic capacity.
NOTE: If it is necessary to replace the filters, replace both filters in use with new ones at the same time. It is forbidden to replace one
filter and leave the filter previously used in the equipment.
© Jack Sealey Limited
PARTICULATE FILTER P3R - PACK OF 2
9007
MODEL NO:
UE/557/2021/1437
Centralny Instytut Ochrony Pracy – Panstwowy Instytut Badawczy (CIOP-
Original Language Version
CLASS
GAS FILTERS
1
Gas concentration
1000 ppm (0.1%)
2
Gas concentration
5000 ppm (0.5%)
3
Gas concentration
10000 ppm (1%)
MARKS
T-B, T-BL, T-BM – filter type
P2 and P3 – filter class according to EN 43:2000/A1:2006
A- filter containing carbon fleece
R – reusable filter
VENTUM – filter manufacturer
PARTICULATE FILTERS
Penetration 20%
Penetration 6%
Penetration 0.05%
9007
Issue 1
01/05/24

Advertisement

loading

Summary of Contents for Sealey WORKSAFE 9007

  • Page 1 PARTICULATE FILTER P3R - PACK OF 2 9007 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. REFER TO INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY.
  • Page 2 Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. EU | Sealey EU Ltd, Farney Street, Carrickmacross, Co. Monaghan, A81 PK68 Ireland UK | Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk...