hit counter code
ABB BAMU-12C Hardware Manual
ABB BAMU-12C Hardware Manual

ABB BAMU-12C Hardware Manual

Auxiliary measurement unit
Hide thumbs Also See for BAMU-12C:

Advertisement

Quick Links

ABB INDUSTRIAL DRIVES
BAMU-12C auxiliary measurement unit
Hardware manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB BAMU-12C

  • Page 1 — ABB INDUSTRIAL DRIVES BAMU-12C auxiliary measurement unit Hardware manual...
  • Page 3 BAMU-12C auxiliary measurement unit Hardware manual Table of contents 3. Installation 3AXD50000117840 Rev C Original instructions EFFECTIVE: 2024-07-05...
  • Page 5: Table Of Contents

    Table of contents 5 Table of contents 1 Introduction to the manual Contents of this chapter ............... . Safety instructions .
  • Page 7: Introduction To The Manual

    Safety instructions for ACS880 liquid-cooled multidrive cabinets and modules (3AXD50000048633 [English]). WARNING! Note that BAMU-12C auxiliary measurement unit is used for measuring main circuit voltage. Main voltage can be present even if auxiliary circuit voltages are switched off.
  • Page 8: Target Audience

    8 Introduction to the manual Target audience This manual is intended for people who install, start-up or operate drives or multidrive modules with BAMU-12C auxiliary measurement unit. The reader is expected to know the fundamentals of electricity, wiring, electrical components and electrical schematic symbols.
  • Page 9: Hardware Description

    Hardware description Contents of this chapter The chapter describes the hardware of BAMU-12C auxiliary measurement unit. Hardware description BAMU-12C auxiliary measurement unit is a measurement unit for precise voltage and current measurements. The unit has: • two 3-phase voltage inputs •...
  • Page 10: Layout Drawing

    10 Hardware description Layout drawing Voltage measurement connector. For pin descriptions, see section Voltage meas- urement connections (XU1, XU2) (page 14). Voltage measurement connector. For pin descriptions, see section Voltage meas- urement connections (XU1, XU2) (page 14). Current measurement connector. For pin descriptions, see section Current meas- urement connections (XIU, XIV, XIW) (page 15).
  • Page 11: Installation

    Installation 11 Installation Contents of this chapter The chapter instructs in installing BAMU-12C auxiliary measurement unit. Checking the delivery The package contains the measurement unit. Make sure that there are no signs of damage. Placing WARNING! Protect the unit against accidental contact. There are connectors that are connected to drive main circuit potential.
  • Page 12: Mechanical Installation

    12 Installation Mechanical installation WARNING! Obey the safety instructions of the drive. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation, commissioning or maintenance work. Stop the drive and do the steps in section Electrical safety precautions in the drive safety instructions.
  • Page 13: Electrical Installation

    Installation 13 Electrical installation WARNING! Obey the safety instructions of the drive. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrical professional, do not do installation, commissioning or maintenance work. WARNING! Stop the drive and do the steps in section Electrical safety precautions in the drive safety instructions.
  • Page 14: Voltage Measurement Connections (Xu1, Xu2)

    14 Installation Voltage measurement connections (XU1, XU2) ■ Pin descriptions of connector XU1 are given in the table below. Name Description U-phase 1 Not connected V-phase 1 Not connected W-phase 1 Not connected Neutral 1 Pin descriptions of connector XU2 are given in the table below. Name Description U-phase 2...
  • Page 15: Current Measurement Connections (Xiu, Xiv, Xiw)

    Connection to the control unit ■ Connect BAMU-12C auxiliary measurement unit to the first unused channel of the control unit of the supply or converter unit of the drive with fiber optic cables. For parameter settings, refer to the appropriate firmware manual of the supply or converter...
  • Page 16: Wiring Example - Voltage And Current Measurements In Use

    16 Installation Wiring example – Voltage and current measurements in use ■ Note: If you use BAMU-12C auxiliary measurement unit in an optimal grid control system, this diagram is not valid. Refer to ACS880 multidrives, Optimal grid control (option +N8053) supplement manual (3AXD50000220717 [English])
  • Page 17: Wiring Example - Voltage Measurement In Weak Network

    Installation 17 Wiring example – Voltage measurement in weak network ■...
  • Page 18: Wiring Example - Dc/Dc Converter

    18 Installation Wiring example – DC/DC converter ■...
  • Page 19: Technical Data

    Technical data 19 Technical data Contents of this chapter The chapter contains the technical data of BAMU-12C auxiliary measurement unit.
  • Page 20: Dimension Drawing

    20 Technical data Dimension drawing Dimensions in mm (1 mm = 0.0394 in)
  • Page 21: Specifications

    Distances to other com- 690 V AC basic insulation (8 mm [0.31 in]) from control electronics ponents Ambient conditions BAMU-12C auxiliary measurement unit complies with RoHS directive (2002/95/EC). Operating temperature 0… +70 °C (32…158 °F) without self-heating Storage temperature -40…+85 °C (-40…185 °F)
  • Page 22: Related Standards

    22 Technical data Related standards • Safety requirements: EN 50178 Electronic equipment for use in power installations • IEC 61800-5-1 Semiconductor power converters for adjustable frequency drive systems • UL 508 C Industrial Control Equipment • EMC emission: EN/IEC 6100-6-4:2007 Emission standard for industrial environments •...
  • Page 23: Further Information

    Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/contact-centers.
  • Page 24 3AXD50000117840C © Copyright 2024 ABB. All rights reserved. Specifications subject to change without notice.

Table of Contents