4.1

E, T TYPE

4.1.1 Test Equipment Required for Alignment
Test Equipment
1. Standard Signal
Generator (SSG)
2. Power Meter
3. Deviation Meter
4. Digital Volt Meter
(DVM)
5. Oscilloscope
6. Frequency Counter
7. Ammeter
8. AF Volt Meter (AF VM)
9. Audio Generator (AG)
10. Distortion Meter
11. 8ohm Dummy Load
12. Regulated Power Supply
*The test equipment which is not used for adjustment is contained in this table.
ANT cable (E30-3418-25)
Modify the ANT cable as shown below.
1-16 (No.RA079<Rev.001>)
SECTION 4

ADJUSTMENT

Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measuring Range
Frequency Range
Measuring Range
Input Impedance
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Cut
Major Specifications
100 to 520MHz
Frequency modulation and external modulation
-127dBm/0.1μV to greater than -47dBm/1mV
50ohm
100 to 520MHz
Vicinity of 10W
100 to 520MHz
10mV to 10V DC
High input impedance for minimum circuit loading
DC through 30MHz
10Hz to 1000MHz
0.2ppm or less
5A
50Hz to 10kHz
1mV to 10V
50Hz to 5kHz or more
0 to 1V
3% or less at 1kHz
50mV to 10Vrms
Approx. 8ohm 3W
5V to 10V, approx. 3A
Useful if ammeter equipped
Solder the ANT cable to the ANT terminal on the TX-RX unit.
ANT
GND
ANT cable
R147
C402
C401
R127
C124
C125