1 Purpose of this manual The purpose of this Service Manual is to provide Service Engineers, who already have the basic knowledge necessary to repair household dishwashers, with technical information regarding dishwashers featuring the EDW1500-1510 electronic control system. These appliances are manufactured at Solaro (Italy). The EDW1500-1510 control system consists of a main circuit board and a control/display board.
4 CONTROL PANEL 4.1 Control panel The configuration of the control panel depends on the following: Typology of the electronic board: horizontal buttons vertical buttons Number of programme selection buttons (from a minimum of 3 to a maximum of 6) Number of LEDs (max.13) Position of the ON/OFF button (right or left) Version EDW1500 with horizontal buttons...
4.1.1 ON/OFF button (S0) The ON/OFF button is featured on all models in the range, and is used to switch the appliance on and off. Switching off does not cancel the programme being executed. The corresponding pilot lamp [L0] lights to indicate that the appliance is powered.
4.1.4 Display The display, which consists of 2,5 digits, can indicate: The indicative time-to-end of the programme in minute. The countdown is carried out every minute and updated at the end of each programme phase (when the programme is updated it can decrease by more minutes at a time or stop for longer).
4.3.3 “1/2 load” The 1/2 load option optimizes the washing cycle when only a small load is placed in the appliance. 1/2 load button • When this button is pressed, certain parameters of the selected washing cycle are modified: Exclusion of Pre-wash (if featured) Reduction of the washing temperature Reduction of the duration of the programme (up to 36 minutes) Automatic 1/2 load...
4.4 Modifying a programme 4.4.1 Cancelling a programme (reset) To cancel a programme that has already started, proceed as follows: 1. Open the door carefully and press buttons S2 - S3 together for approximately 2 seconds: the LED corresponding to the cycle being executed begins to flash. 2.
4.6 Buzzer (only certain models) Normally this series of appliances does not feature the buzzer, but some models do. The buzzer sounds to indicate the end of cycle and in the event of an alarm condition. The buzzer sounds three times at the end of the cycle, but switches off immediately if the door is opened. If the user prefers to switch off the buzzer, it is necessary to press a combination of buttons.
4.7 Sequence of operations 1. Close the door. 2. Press S0 to switch the appliance on. The pilot lamp L0 lights. 3. Select the desired programme. The display shows the time-to-end or the programme no. flashing. The phase LEDs light. 4.
5 STRUCTURAL CHARACTERISTICS 5.1 Structure The appliance as a whole may be considered as consisting of four main assemblies: BASE – DOOR – TUB – HYDRAULIC SECTION The four assemblies are enclosed in a structure consisting of: - A lower front panel (secured by two screws) - Two lateral panels (secured by six screws).
6 ELECTRICAL COMPONENTS AND THEIR FUNCTIONS 6.1 EDW1500-1510 Electronic control system The EDW1500 control system consists of a main circuit board and a control/display board. Both boards are housed in a plastic container. Version with horizontal buttons Version with vertical buttons 6.1.1 Functions of the circuit board DISPLAY BOARD...
6.2 Specifications for actuators and sensors 6.2.1 Components TYPE OF ELECTRONIC TYPE OF COMPONENT POWER AVAILABLE CONTROL Wash pump Max 250W Triac Drain pump Max 100W Triac Heating element Max 2100W Relay Water fill solenoid Max 10W Triac Regeneration solenoid Max 10W Triac Detergent and Rinse-aid solenoid...
6.3 Power supply and programme selection The main board is powered by the closure of contacts 1-5 and 2-4 of the ON/OFF button (PU). The connectors used in this case are A2 (neutral) and B1 (line). The control/display board (user interface) is powered at 5V by the main board, making programme selection possible.
6.4 Fill circuit 6.4.1 Level and anti-overflow pressure switch The level of water introduced into the appliance is determined by • the level pressure switch (A) The anti-overflow pressure switch (B) ensures that the level of • water does not exceed the safety threshold (causing overflow from the door).
6.5 Control of water fill phase The quantity of water necessary to carry out the washing cycle is determined exclusively by the closure of the electrical contact of the pressure switch, which changes from EMPTY to FULL. This system ensures that, if the pressure switch re-opens on EMPTY, further water is introduced until it returns to FULL.
6.7 Level stability during washing Once the fill phase has been completed, the cycle proceeds to the washing phase. The washing phase is carried out using cold or heated water, and the status of the pressure switch is monitored constantly to ensure that the hydraulic system functions correctly.
6.9 Heating The heating element is enclosed in a protective tube, and is used to heat the washing water (but does not switch on during the drying phase) The heating element is fitted to the outlet of the washing pump and connected to the duct which feeds the upper spray arm.
6.10 Disactivating the rinse-aid function Introduction of rinse-aid may be disactivated by the user by pressing a combination of buttons. In this case, the Rinse-aid LED (if featured) will also be disactivated. 1. Cancel any cycles that may have been selected. 2.
6.12 Regeneration system Regeneration of the softening system, whose duration is approximately 4 minutes, is normally performed at the beginning of the drying phase. Each time regeneration is performed (the regeneration solenoid 4 is energized), the chamber is completely emptied (about 230 cc of water). Regeneration is controlled by the electronic control system “Ad Hoc”, i.e.
6.14 Regeneration levels The counter for execution of the “Ad Hoc” regeneration process is governed by the electronic control system on the basis of the duration of the fill phases (i.e. the quantity of water introduced), and NOT on the number of cycles.
6.14.3 Table of regeneration values Water introduced Aperture of Position of between Hardness of the regeneration selector in Level Display regeneration water solenoid the tub cycles litres nº º F (TH) º D (dH) - - - 0 > 8 0 >...
8 Automatic cycle 8.1 Turbidity sensor Certain models which feature the turbidity sensor may also feature a special “automatic” programme which optimizes the cycle according to the size of the load and the degree of soiling. This sensor is positioned externally to the sump, in direct contact with the water.
9 Alarms In the event that an abnormal situation should occur which might affect the correct operation of the appliance, the circuit board causes a safety system to intervene. In most cases, this interrupts the washing cycle. The last three alarm conditions are stored in memory. Using a special procedure available only to Service Engineers, it is possible to read all the alarms stored in memory.
Page 28
No. flashes Displayed Type of of end-of- to the Description of the alarm condition Machine status Possible causes alarm cycle LED user and “beeps” Heating Time-out The programme continues to the Heating element faulty; intervention of safety (the check takes place every 3 minutes: end without heating (the washing thermostats (open);...
10 Diagnostics mode / Options A single procedure can be used by Service Engineers to access the diagnostics system. After accessing diagnostics mode, the Engineer can: read / cancel the alarms, check for correct operation of the various components of the appliance, start the diagnostics cycle and select the options available to Service Engineers.
10.3 Cancelling alarm codes from memory / Testing the LEDs It is good practise to cancel the alarm codes after reading the alarm code or after effecting repairs to check whether it is repeated during the diagnostics test. 1. Access diagnostics mode (see 10.1) 2.
10.5 Options available to Service Engineers In particular circumstances, i.e. if the user reports unsatisfactory washing results, a special procedure, available only to Service Engineers, can be used to select two supplementary options designed to improve performance: Extra cold rinse. •...
10.5.2 Disabling pulse washing Certain programmes use the pulse washing system (PW). Using the procedure described below, the Service Engineer can modify this system so that Ctrl (continuous) washing is used in all those programme which normally use the PW system. This intensifies the washing action even in delicate programmes. Disactivation/activation mode 1.
11.2 Basic circuit diagram 11.2.1 Key to circuit diagram CO = Capacitor PA = Anti-overflow pressure TAC/T = Tachymetric generator AR = Orange MR = General terminal block NE = Black DD = Detergent/ Rinse-aid switch TS = Safety thermostat BI = White MV = Fan motor RO = Pink...
11.3 Table of programmes The table below lists the phases of the programmes for this type of appliance. As these can be configured differently, refer to the relative documentation for the specific cycles available for each model. Extra Programmes Pre-wash Wash Cold Rinse 2nd Cold Rinse...
11.4 Checking the efficiency of the components In order to facilitate the control procedure for the components to be tested, a TEST PROCEDURE has been created which indicates the point to which the probes of the tester should be applied and the correct theoretical value for each component tested.
12 QUICK GUIDE TO THE SPECIAL FUNCTIONS The table below briefly describes how each of the special functions available to the user and to the Service Engineer can be used. Function Activation of the function Starting the function Brief description / Comments Keys Led(s) Keys...