Installing socket switching module HS 20 to Hometronic Manager as a collection relay Successful Teach-in Failed Teach-in Operation Operating the socket switching module manually Controlling the socket switching module with the Hometronic Manager Device switch HS 20 as a collection relay of thermostat control Appendix Glossary...
Page 4
Overview Technical data Information to the customer Help with problems Notes...
Technical terms are explained in the glossary (Page 15). They are identified in the text by an *. Application The socket switching module HS 20 is a switching module for electrical switchgear. It can be switched on and off from the Hometronic Manager* or by using the Hometronic remote control*.
Overview Housing Length: 153 mm Width: 63 mm Height: 39 mm (housing without plug) Status display (green LED) Button for manual operation and Teach-in...
Teach-in Teach-in The new Hometronic components first have to be assigned to the Hometronic Manager before they can be taken into operation. This process is called the "Teach-in". The Hometronic Manager and the new components exchange data during the procedure. The socket switching module has a radio receiver whose function can be impaired by metallic objects! When selecting the operating site ensure that there is...
Page 8
Teach-in LED display during the Teach-in LED on Display Status LED off LED flashes rapidly Teach-in not carried out Teach-in mode LED flashes (duration 4 minutes) LED off Teach-in successful LED lights up green with short breaks Teach-in failed Note: The Teach-in mode can be aborted by pressing the button at the switching module briefly.
Teach-in Assignment to Hometronic Manager HCM 200 Switching to "Settings" submenu of Hometronic Manager The Hometronic Manager is in automatic mode. The display* at the Hometronic Manager HOMETRONIC shows the standard display (example): WE 29.10.1999 11:15 No Lifestyle active LIVING 20.0 C Press the Dial button.
Teach-in Assigning socket switching module HS 20 to Hometronic Manager as a device Change to the "Settings" submenu as on Page 7. ► Turn the Dial button to the until HEATING/COOLING ► SHUTTERS "Settings" is selected. DEVICES/LIGHT Press the Dial button.
Manager as a collection relay Example: Installing socket switching module HS 20 as a collection relay. Activate Teach-in mode at the HS 20 as described on Page 5. ► Change to the "Settings" submenu as described on Page 7. ►...
Page 12
ANTI-FREEZE SENSOR An "*" appears after the "Thermostat" THERMOSTAT entry. The device switch is assigned. The socket switching module HS 20 is installed as a collection relay. Uninstalling collection relay Change to the "Settings" submenu (refer to Page 7). ►...
Teach-in Press the Dial button. SWITCHING MODULE ► ANTI-FREEZE SENSOR The following text is displayed: THERMOSTAT Turn the Dial button to the left until SWITCHING MODULE ► ANTI-FREEZE SENSOR "Thermostat" is selected. THERMOSTAT Press the Dial button. SWITCHING MODULE ► ANTI-FREEZE SENSOR The "*"...
Teach-in Failed Teach-in The Teach-in has failed when the LED at the switching module flashes green with short interruptions. The data transfer per radio did not take place or was faulty. Note: Since the socket switching module tries to establish a con- nection to the Hometronic Manager for the duration of 4 minutes, a failed Teach-in is not displayed by the LED until after the 4 minutes have passed.
Page 15
Teach-in Repeating the Teach-in Press the Dial button in order to MODULE-1 ► MODULE-2 activate the Teach-in mode. MODULE-3 MODULE-4 The module is activated again for teaching-in.
Operation Operation Exceeding the maximum connected load* can destroy the switching module. Fuse the switching module with a maximum of 16 A. Caution! ► Insert the device into the socket switching module. ► Operating the socket switching module manually In order to switch plugged-in devices on or off, press briefly on the button of the socket switching module.
Device switch HS 20 as a collection relay of thermostat control A device switch HS 20 can be used (as a collection relay) for feedback of the heat generation with thermostat control. The collection relay switches the boiler on as soon as a relay in a zone under thermostat control is activated.
Appendix Appendix Glossary Connected load Intake power of the plugged-in Light-emitting diode device. Lifestyle Presence simulation Combination of functions and The operation course of the last 7 time programs which days is repeated. Hometronic sets in accordance with a certain Lifestyle, e.g. Cursor "Party"...
Appendix Technical data Operating voltage 230 V AC, 50 Hz Intake power Approx. 1 W Operating temperature 0...40 °C Degree of protection IP 30 Storage temperature –20 °C...+70 °C Maximum humidity 95 %, non-condensing Limiting data of the connected load Max.
Appendix Information to the customer After the Teach-in has been completed (in this case of the socket switching module) the customer can be informed via the Hometronic System: Familiarize the customer with the basic operation of the Hometronic ► Manager. Explain the operation of the components on site.
Appendix Help with problems Problem/Display Cause Remedy LED lights up green See "Improving the Teach-in failed ► data transfer" with short breaks (Page 12). Repeat the Teach-in. ► Increase the distance No control by Radio connection ► to the next socket Hometronic Manager is disturbed switching module...
Page 24
Honeywell AG Böblinger Straße 17 D – 71101 Schönaich Telephone (+49) 7031 637-300 This company is certificated to The right is reserved to make modifications. This document is definitive for the enclosed product and replaces all previous publications. No. 7157519...