Tab le of c ont e nts Notes on the instruction manual ......................4 Safety ..............................4 Intended use ............................4 Environment ............................5 ABB devices ..........................5 Product description ..........................6 Device type ..........................6 Terminal description ........................7 Technical data ............................8 Mounting/Installation ..........................
Page 3
Table of contents Product manual 2TMD041800D0042 │3...
Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. ABB accepts no liability for any failure to observe the instructions in this manual. Safety...
ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company.
Product description Product description Device type Size (DxHxW) Article Product ID Product name Colour number Unit: mm H8308 2TMA130160H0051 IP Elevator controller Grey 90 x 72 x 65 Product manual 2TMD041800D0042 │6...
Product description Terminal description Function System power supply connector RS485 connector LAN (PoE) Reset button Press and hold this button for 10 seconds at any time to restore the device to the factory defaults. The status indicator will go off for 3 seconds then start to flash slowly. Status indicator On: the device is working normally ■...
Technical data Technical data Designation Value Rating voltage ⎓ 24 V Operating voltage range ⎓ 20-27 V Rating current ⎓ 24 V , 60 mA Operating temperature -20 °C…+55 °C Storage temperature -20 °C…+70 °C PoE standard IEEE802.3 af Product manual 2TMD041800D0042 │8...
Mounting/Installation Mounting/Installation Warning Electric voltage! Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. – Disconnect the mains power supply prior to installation and/or disassembly! –...
Commissioning Commissioning Topology Outdoor station Outdoor station type Support "Elevator control" or not? IP touch 5 outdoor station Yes, but its firmware version should be V1.32 or higher IP keypad outdoor station Yes, but its firmware version should be V1.32 or higher IP pushbutton outdoor station Yes, but its firmware version should be V1.32 or higher Mini outdoor station...
Page 12
Commissioning Capacity One block supports a maximum of 4 IP elevator controllers. One IP elevator controller supports a maximum of 16 relay modules. One relay module supports a maximum of 16 channels. Product manual 2TMD041800D0042 │12...
Commissioning Adding devices Precondition All the devices to be added manually must be powered on. ■ None of the devices to be added manually should be signed by another "Smart Access ■ Point". If the devices have been signed by another "Smart Access Point", you need to clear the signature e.g.
Page 14
Commissioning [2] On the "Door Entry System" screen, click "Add device". [3] Select "Elevator Controller" from the drop-down list. [4] Enter the block number. [5] Enter the device number. [6] Enter the serial number. [7] Click "Save". Note If the device has already been signed by another "Smart Access Point", it will not be signed.
Commissioning Accessing the setting screen Please follow the steps below: [1] On the "Door Entry System" screen, click "Elevator Controller". [2] Click the designated elevator controller to access the corresponding screen. [3] Click "Settings" to access the settings screen. [4] If you have already saved a configuration, click "Saved Configuration" to edit the existing settings directly.
Commissioning Basic information On the "Settings" screen: Description Display the physical address of the device (block no. & device no.). Display the serial no. of the device. Display the firmware version and MCU version of the device. Product manual 2TMD041800D0042 │16...
Commissioning Configure mode There are 3 optional configuration modes. Pre-configuration Semi-automatic Manual mode mode configuration mode Lowest floor level below ground Highest floor level above ground Maximum number of according to actual according to actual elevators supported requirement requirement Maximum number of outdoor stations supported Call elevator according...
Commissioning 8.5.1 Pre-configuration mode This mode is usually used for a simple project, e.g. a building which has not more than 18 floors above the ground floor. This mode can guide you through completion of all configuration work step by step. User case 1 Question Answer...
Page 19
Commissioning [2] On the "Floors Selection" screen: Select the designated floors needed to support the "elevator control" function. ■ – When a floor is pressed, the selection will be visual. – Click "Select all" to select all floors – Click "Inverse" to invert the selection of existing floors. Note Please note that the first floor above the ground will be indicated with the number 1, and the one right below, with the number -1.
Page 20
Commissioning [3] On the "OS Setup" screen: Select the floor for each outdoor station to be installed ■ – Click "Add an outdoor station", then set the device no. and the floor no .for the outdoor station installed. – Click " "...
Page 21
Commissioning [5] On the "Result" screen: The recommended relay configurations will be displayed automatically. ■ [6] Click "Save". The data can be viewed on the "Save Configuration" screen. [7] Click "Print" to print out the relay configurations for installation reference. [8] On the "Installation Guidelines"...
Commissioning 8.5.2 Semi-automatic configuration mode This mode can be used for a medium-sized project, e.g. a building which has not more than 32 floors above the ground floor. Please see the "Configure mode overview" chapter for more details. This mode can give you some freedom when configuring the settings. User case 2 Question Answer...
Page 23
Commissioning [2] On the "Floors Selection" screen: Select the designated floors which need to support the "elevator control" function. ■ – When a floor is pressed, the selection will be displayed visually. – Click "Select all" to select all floors. –...
Page 24
Commissioning [3] On the "OS Setup" screen: Select the floor for each outdoor station to be installed ■ – Click "Add an outdoor station", then set the device no. and the floor no .for the outdoor station installed. – Click " "...
Page 25
Commissioning [5] On the "Recommendation" screen: The number of relay modules recommended will be displayed. ■ Click "Next". ■ [6] On the "Selection of Relay" screen: Select the designated relay modules by ticking the checkbox. ■ – indicates the selected relay modules have been configured before. –...
Page 26
Commissioning [7] On the "Channel Setup" screen, Select the floor no. and the function for each channel. ■ – "Calling up" – "Calling down" – "Authorization" Click "Clear" to clear all the inputs in the table for the current relay module. ■...
Commissioning 8.5.3 Manual mode This mode can be used for a large project, e.g. a building which has no more than 63 floors above the ground floor. Please see "Configure mode overview" chapter for more details. This mode gives you complete freedom when configuring the settings. There are 3 events that need to be set in manual mode: 1.
Page 28
Commissioning User case 3 Question Answer Which floors need to support the -1, 1, 2, 3, 4, 5, 6 elevator control? Outdoor station 1 is installed on floor 1 Where are the outdoor stations installed? Outdoor station 2 is installed on floor -1 Is the "call elevator from indoor station"...
Page 29
Commissioning [3] On the "Calling From IS" screen, set the data as below: Click "Add a row" to add a record. ■ Click "Delete selected row" to delete the selected row. ■ Click "Next" to continue the setting. ■ [4] On the "Authorization Flat to Flat" screen, set the data as below: Click "Add a row"...
Page 30
Commissioning Exporting CSV file [1] Don’t change the event title (marked in red). [2] Don’t change the column title or the column order (marked in blue). Product manual 2TMD041800D0042 │30...
Commissioning 8.5.4 Editing the existing configuration Please follow the steps below: [1] On the designated IP elevator controller screen, click "Saved Configuration". [2] Click "Edit" to edit the existing configuration. Product manual 2TMD041800D0042 │31...
Commissioning Parameter settings 8.6.1 Relay status for authorization Please follow the steps below: [1] On the "Settings" screen, click "Relay status (NC/NO) for authorization". [2] Select the relay status: ■ ■ [3] Click "Save". Product manual 2TMD041800D0042 │32...
Commissioning 8.6.3 Relay hold time for calling elevator Please follow the steps below: [1] On the "Settings" screen, click "Relay hold time for calling elevator". [2] Select the hold time for calling the elevator: 1 second ■ 2 seconds ■ 3 seconds (default) ■...
Commissioning Updating the firmware 8.7.1 Updating the firmware via local PC Please follow the steps below: [1] On the "Settings" screen, click "Local firmware update". [2] Click "Browse" to search the firmware update file. [3] Click "Browse" to search the firmware signature file. [4] Click "Firmware update".
Page 36
Commissioning [5] Click "I agree" to agree the "End user license agreement". [6] Click "Close" when the update is complete. Product manual 2TMD041800D0042 │36...
Commissioning 8.7.2 Updating the firmware via website Please follow the steps below: [1] On the "Settings" screen, click "Online firmware update". [2] Current firmware version is displayed on the screen. [3] New firmware version will be displayed on the screen. If there is no new version, "Current version is up to date"...
Commissioning Commissioning multiple devices in batches Please follow the steps below: [1] On the "Elevator controller" screen, [2] Click " ". [3] Select the designated devices. – When a device is pressed, the selection will be visual. – Click "Select all" to select all devices [4] Click "Next".
Page 39
Commissioning [5] "xx devices" will be displayed on the title to indicate multiple devices are set at the same time. [6] There are multiple functions can be select on the "List view" menu bar. Select a function to continue the setting. The operation is the same as that of a single device. Product manual 2TMD041800D0042 │39...
Cyber security Disclaimer H8308 product is designed to be connected and to communicate information and data via a network interface, which should be connected to a secure network. It is customer‘s sole responsibility to provide and continuously ensure a secure connection between the product and customer‘s network or any other network (as the case may be) and to establish and maintain...
Malware prevention solution The H8308 device is not susceptible to malware, because custom code cannot be executed on the system. The only way to update the software is by firmware upgrading. Only firmware signed by ABB can be accepted.
We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice. The detailed specifications agreed to at the time of ordering apply to all orders. ABB accepts no responsibility for possible errors or incompleteness in this document.
Page 43
Contact us Notice We reserve the right to at all times make technical changes as well as ABB Xiamen Smart Technology Co., Ltd. changes to the contents of this No. 881, FangShanXiEr Road, Xiang’An Industrial document without prior notice. Area, Torch Hi-Tech Industrial Development...