hit counter code
i4Technology EcoLife Pro1 Instruction Manual

i4Technology EcoLife Pro1 Instruction Manual

Radiation meter

Advertisement

Quick Links

Table of contents

Introduction
1.
1.1.
1.2.
1.3.
1.4.
1.5.
Identification and sealing
2.
2.1.
2.2.
2.3.
Operation
3.
4.
5.
6.
7.
8.
Appendix. General information of the radiation nature and the material-radiation
interaction.
This manual is to get you acquainted with the Radiation meter EcoLife Pro1 internal
design, working principles and rules of operation (correct use, maintenance, storage and
transportation).
In production the device construction and electrical scheme can be modified. It does not
impact the technical and metrological features of the product, - that's why the modifications are
not mentioned in this manual.
«I4Technology» OOO (Ltd.)
Radiation meter EcoLife Pro1
Instruction manual INTС.412113.001 RE

Advertisement

Table of Contents
loading

Summary of Contents for i4Technology EcoLife Pro1

  • Page 1: Table Of Contents

    Warranty Card Appendix. General information of the radiation nature and the material-radiation interaction. This manual is to get you acquainted with the Radiation meter EcoLife Pro1 internal design, working principles and rules of operation (correct use, maintenance, storage and transportation).
  • Page 2: Specification And Operation

    The Radiation meter EcoLife Pro1 is a hand-held device, produced to control the background radiation indoors and outdoors by measuring: - the ambient dose of photon and gamma radiation and the ambient dose rate; - the activity concentration of beta and gamma radioactive nucleus in substances.
  • Page 3: Technical Features

    1.1.2 The software of the equipment provides: − the special measuring algorithm. According to this algorithm the unit estimates and corrects the measured data every 10 seconds repeatedly. In constant ionization radiation field the readings taken by the unit are being continuously corrected and averaged to reduce the statistical error.
  • Page 4: Contents Of The Box

    Operating Instructions INTC.412113.001RE 1.4. Internal design and operating 1.4.1. The Radiation meter EcoLife Pro1 is a portable device with the self-contained power supply. The case (no. 1) made of the impact-resistant plastic has a unit for batteries (no. 2) with a cover (no.
  • Page 5 Fig. 2 –Main parts scheme 1.4.2. The radiation detector used in the device is a gas-discharge meter. By it the photon flux is transformed into the sequence of electrical signals by the radiation detector. These signals are processed by the smart detection circuit that provides the automatic processing of the ambient dose and the ambient dose rate measured data and the display indication.
  • Page 6: Correct Use

    The Radiation meter EcoLife Pro1 automatically summarizes the accumulated dose from the moment of switching on and for all the periods of working.
  • Page 7: Pre-Starting Procedure

    2.1.3. Ensure before charging the accumulators as part of the product (installed into the product’s case) that there are the accumulators not galvanical batteries installed into the battery compartment. It’s prohibited to charge the galvanical batteries, you must renew them. 2.1.4.
  • Page 8 the choice by pushing the «ОК» or «˃» button; - choose the language «РУССКИЙ» or «ENGLISH» in the opened submenu and confirm the language by pushing the «ОК» button. You’ll see the check mark opposite the chosen language; - by pushing the buttons «<» or come back to the Main menu for further settings.
  • Page 9 - by pushing the button «<» or the button come back to the Main menu for further settings. 2.3.1.6. Setting the screen When you are in the Main menu (fig. 7), by pushing the buttons «˄» and «˅» choose the line «НАСТРОЙКИ...
  • Page 10 - in the Screen settings menu (fig. 9), by pushing the buttons «˄» and «˅» choose the line «ТЕМА (SKIN)» and confirm your choice by pushing the button «ОК» or «˃»; БЕЛЫЙ (WHITE), or - in the opened submenu choose one from available colors КРАСНЫЙ...
  • Page 11 opposite the chosen value you’ll see the check mark; - by pushing the button «<»,come back to the Sound settings menu (fig. 10). 2.3.1.14. Setting the sound volume - in the Sound settings menu (Рис. 10), by pushing the buttons «˄» and «˅» choose the line «ГРОМКОСТЬ(VOLUME) and confirm your choice by pushing the button «ОК»...
  • Page 12 Figure 11 – Current time setting menu - navigating through the Current time setting menu by pushing the buttons «˃» and «<», set the current time (can be altered by pushing the buttons «˄» and «˅»), and after it remove the mark in the icon «ОК», and confirm your choice by pushing the button «ОК».
  • Page 13 Figure 12 – Information about the manufacturer - by pushing the button «<» or the button come back to the Main menu. 2.3.3. Browsing the software version The current software version is displayed in the Main menu (Fig.7) (see the line «ВЕРСИЯ ПО...
  • Page 14: Technical Service

    measuring the device should be placed at the height of 5 meters above the ground. The measuring time is about 20…30 minutes. Note. If possible inspect the objects comprehensively in compliance with the requirements of the following statutory documents to receive the most meaningful measurements: «Ionization radiation, radiation security and radiation safety standards (RSS-99).
  • Page 15: Failure Table

    − shock acceleration peak values below 147 m/s2 (15 g), with shock acceleration duration 10-15 ms. While shipping and transporting the requirements of the package warning labels should be performed rigorously. 6. Proof of acceptance Radiation meter EcoLife Pro1 TC 4362-007-64062607-2015...
  • Page 16: Manufacturer's Warranty

    7.6. When the guaranteed use period ends, the maintenance of the Product will be provided at the expense of a Consumer. ООО «I4-Technology» www.i4Technology.ru 8. Certification information 8.1. The Product satisfies the requirements of the Technical Regulation of Customs Union TR CU 020/2011 "Electromagnetic compatibility of technical equipment".
  • Page 17: Warranty Card

    Warranty Card Product name: Radiation meter EcoLife Pro1 Manufacturing number ______________________________________________________________________ Manufacture date ______________________________________________________________________ QC stamp ___________________________________________________________________________ Sale Date _________________________________________________________________________ Vendor’s stamp and signature ______________________________________________________________ The customer does not have any claims on quality of the Product and the contents of delivery.
  • Page 18 Appendix. General information about the nature of radiation and the material- radiation interaction Radioactivity is the process of spontaneous nuclear decay by which an unstable atom (uranium, thorium, radium etc.) changes the atomic and mass number. Such elements are considered radioactive. The radioactive decay has a strictly defined constant speed measured by the half-life period (the time required for one half of the atoms to disintegrate).
  • Page 19 produced by the absorbed dose of 1 Gy of photon radiation. The non-SI unit of the equivalent dose is roentgen-equivalent-man (rem). 1 Sv = 100 Rem The equivalent dose rate (H) is defined by the formula: H= dH/dT, where dT is a period of time. In the SI system the equivalent dose rate (H) is measured by Sievert per second (Sv/s).