Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
An operating temperature range of -40 to 85°C (-40 to 185°F) allows the RUGGEDCOM RS1600T to be placed in almost any location. For applications requiring high availability the RUGGEDCOM RS1600T provides the option for integrated dual redundant power supplies each capable of accommodating a wide range of input voltages for worldwide operability.
Terminal blocks for reliable maintenance free connections • CSA/UL 60950 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS1600T features various ports, controls and indicator LEDs on the front and rear panels for configuring and troubleshooting the device. RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Page 12
"Connecting to the Device (Page 17)". Communication Ports Receive and transmit data. For more information about the various ports available for the RUGGEDCOM RS1600T, refer to "Communication Ports (Page 19)". RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
"Dimension Drawings (Page 23)". 2.1.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RS1600T can be equipped with rack mount adapters pre-installed. Note The chassis features multiple mounting holes, allowing the rack mount adapters to be installed up to 25 mm (1 in) from the face of the device.
2.1.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS1600T can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
Install the supplied screws to secure the adapters to the panel. Connecting Power The RUGGEDCOM RS1600T supports single or dual redundant high AC, high DC and/or low DC power supplies. The use of two power modules is recommended to provide redundancy and load balancing.
This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing. RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing. RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Connect the ground terminal on the power source to the chassis ground terminal on the device. 2.2.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Page 23
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. POWER SUPPLY 1 POWER SUPPLY 2 Figure 2.6 Single AC Power Supply Figure 2.7 Single DC Power Supply Figure 2.8 Dual AC Power Supply Figure 2.9 Dual DC Power Supply RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Control of the failsafe relay output is configurable through RUGGEDCOM RS1600T . One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the RUGGEDCOM RS1600T User Guide for the RUGGEDCOM RS1600T.
Clear To Send Reserved (Do Not Connect) Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS1600T console and Web interfaces via the device's IP RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
19)". Resetting the Device The RUGGEDCOM RS1600T can be reset (rebooted) using the RESET button. The RESET button is recessed and can only be reached using a pin or small screwdriver. To reset the device, quickly press and release the RESET button with a pin.
RS1600T . For more information on how to access the factory data file, refer to the RUGGEDCOM RS1600T User Guide for the RUGGEDCOM RS1600T. Each communication port type has a specific place in the RUGGEDCOM RS1600T chassis. Ports 1 to 14 Ports 15 to 16 Figure 4.1...
Tx Connector Tx Connector Rx Connector Rx Connector Figure 4.4 LC Port Figure 4.3 MTRJ Port For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications (Page 22)". RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
30 VAC 0.3 A 30 VDC 80 VDC 0.3 A Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RS1600T. Maximum Speed ConnectorDuplex Cable Type Wiring Standard Isolation Distance...
Typical distance. Dependent on the number of connectors and splices. RMS 1 minute. Fiber Optic Ethernet Port Specifications The following details the specifications for fiber optic Ethernet ports that can be ordered with the RUGGEDCOM RS1600T. 10Base-FL/100Base-SX Ethernet Optic Tx (dBm) Power Connector Tx λ...
Information Technology Equipment - Safety - Part 1: General Requirements The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements. A copy of the CSA Certificate of Compliance is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109476557. 6.1.2...
Products with Respect to the Restriction of Hazardous Substances The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
Certification 6.1.8 RoHS 6.1.8 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
Page 40
2.5 kV Common and Differential Mode @ 1MHz HV Impulse Signal Ports 5 kV (Failsafe Relay) DC Power Ports 5 kV AC Power Ports 5 kV Dielectric Signal Ports 2 kVAC (Failsafe Relay) Strength DC Power Ports 1.5 kVDC RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Page 41
Humidity (Damp Test Db 95% (non-condensing), Heat, Cyclic) 55 °C (131 °F), 6 cycles IEC 60255-21-1 Vibration Level 2 (2 g @ 10-150 Hz) IEC 60255-21-2 Shock Level 2 (30 g @ 11 ms) RUGGEDCOM RS1600T Installation Manual, 01/2021, C79000-G8976-1015-03...
Page 42
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...