The contact / voltage state transmitter with receiver (2 pages)
Summary of Contents for ABB Tina 10A
Page 1
Original instructions Tina 10A/B/C Adaptor unit ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage...
Page 2
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted.
Testing of the safety functions ..........................8 Troubleshooting ..............................8 Operation ............................. 9 LED indication..............................9 Information output signal attributes ........................9 Technical data ........................... 10 Dimensions ..............................11 EC Declaration of conformity ......................12 2TLC172145M0201, rev. A www.abb.com/lowvoltage 2011-09-23...
Introduction Scope The purpose of these instructions is to describe the adaptor units Tina 10A/B/C and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB/Jokab Safety products.
Vital safety module or Pluto safety-PLC. Tina 10A, -B and -C are used to adapt Focus light beams and light curtains with OSSD outputs to the dynamic safety circuit. This also enables complete external interconnections using cables with M12 connectors only, which reduces the cabling to and connections in the apparatus enclosure.
5 ) Grey: NB: Shielded cable is recommended between this unit and the rest of the safety circuits. Caution! All cable colours according to ABB/Jokab Safety standard cables. Warning! The information channel output shall never be used for the safety purpose(s).
Connection examples Caution! All cable colours according to ABB/Jokab Safety standard cables. 2TLC172145M0201, rev. A www.abb.com/lowvoltage 2011-09-23...
(EN 62061:2005). In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel.
H) is given in the table below. Info output signal switch Delay ~ 140 ms ~ 2 ms Warning! The information output signal is not a failsafe signal and should never be used for the safety purpose(s). 2TLC172145M0201, rev. A www.abb.com/lowvoltage 2011-09-23...
35 to 85 % (with no icing or condensation) Housing material Connector Tina 10A: M12 8-pole female, M12 5-pole male Tina 10B: M12 8-pole female, M12 5-pole female, M12 5-pole male Tina 10C: M12 8-pole female, M12 5-pole female, M12 5-pole male...
EC Declaration of conformity EC Declaration of conformity (according to 2006/42/EC, Annex2A) ABB AB declare that the safety components of ABB AB make with type designations and safety JOKAB SAFETY functions as listed below, is in conformity with the Directives Varlabergsvägen 11...