"This function has already enabled."
→Check if the security function has
already been enabled.
(4) Press the power switch on the control
panel for 3 seconds or more. Following the
instructions displayed on the shutdown
sequence step by step with operations to
select appropriate items on the touch panel
so that the main switch can be ready for
turning off. Turn the main power off, and
after 10 seconds, turn it on again.
(5) The registered license will be validated
when the power supply of the device itself
is turned on once again.
At the first reboot after the license key
registration, in some cases, it might take 30
min. or more in order to initialize the data
in HDD. If the data erasing method of
HDD of the device is set to "Overwrite
random data 3 times", it might take longer
than the cases above. Make sure not to turn
off the power supply when the message,
"Remaining data that is not needed is being
erased. Do not turn off the main power.",
is displayed.
(6) When the device starts normally, press
counter key and then press the Device
Configuration to check if the security kit is
displayed in the space of options. Then, set
the Service mode at user's request.
1.3.3 Setting the
Service mode
When this kit is installed, the Service mode
needs changing in response to the user's
request.
1. Changing the setting of "Complete
erasing of HDD"
Change the setting of complete erasing of
HDD at user's request.
- Service mode level 2
COPIER>OPTION>USER>HDCR-DSP
Set value
1: Overwrite NULL data one time
2: Overwrite Random data one time
3: Overwrite Random data three times
Default value: 1
Note:
As the value is set higher, the security level
becomes higher while the performance
level becomes lower.
2. Switching the key of "Job Log
Display ON/OFF" between display
and not display
Switch the key of "Job Log Display ON/
OFF" between display and not display.
- Service mode level 2
COPIER>OPTION>USER>LGSW-DSP
Set value
0: Not display the key
1: Display the key
Default value: 0
—
—
11