4.4.4 Inspecting in "User Defined" Mode
In this mode, inspections are executed by each block. Specify a block No.0 to 9 when inputting start signal from
the external devices. (I/O input, serial command communication or Ethernet command communication.) The
checkers, the numerical calculations, and the judgements belong to specified block are executed and output.
The number of the executed block is displayed in the information area.
Specifying Execution Mode and Number of Blocks
1.
Select "TYPE" > "Type Setting" from the menu bar.
"Type Setting" window is displayed.
2.
Select "Execution Condition".
3.
Select "User Defined" for "Execution
Mode".
4.
Enter the number of blocks 2 to 10 for
"Number of Blocks".
How to Set a Block
Specify a block to input a signal and send a command
to execute an inspection.
When inputting a start signal through I/O, specify the
block number with IN 0-3.
When sending a serial command, send a designated
command to specify the block No.
When using "Individual Trigger" for camera trigger, you
cannot execute different blocks for each camera. After
specifying block No.0 with the first camera, specifying
the other block numbers with the second camera stops
inspections and outputs ERROR 0 signal.
Starting an Inspection by Keypad
For the type set as "User Defined", you can specify a block when starting an inspection with the keypad.
1
. Press the TRIG key (Start) in RUN menu.
A window to select a block No. to execute is displayed.
2.
Select the block No. to execute.
The specified block is executed.
78
Block
I/O (STA0-3 +)
IN3
IN2
IN1
No.0
off
off
No.1
off
off
No.2
off
off
ON
ON
No.3
off
off
ON
No.4
off
ON
No.5
off
ON
ON
No.6
off
ON
ON
No.7
off
ON
No.8
off
No.9
ON
off
Serial
command*
IN0
off
off
%S0
ON
off
%S1
off
%S2
ON
%S3
off
off
%S4
ON
off
%S5
off
%S6
ON
%S7
off
off
%S8
off
ON
%S9
(*Individual Trigger: No)