Page 1
Introduction Description IP addresses SIMATIC NET Technical basics Industrial Ethernet switches SCALANCE XM-400/XR-500 Web Configuring with Web Based Management Based Management (WBM) Troubleshooting/FAQ Configuration Manual Appendix A 05/2017 C79000-G8976-C248-12...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
This Configuration Manual applies to the following software version: ● SCALANCE XR-500 firmware as of version 6.1 ● SCALANCE XM-400 firmware as of version 6.1 Purpose of the Configuration Manual This Configuration Manual is intended to provide you with the information you require to install, commission and operate IE switches.
Apart from this configuration manual, the products also have the following documentation: ● Configuration Manual: – SCALANCE XM-400/XR-500 Command Line Interface (CLI) This document contains the CLI commands that are supported by the IE switches SCALANCE XM-400 and SCALANCE XR-500.
Page 13
You will find the SIMATIC NET glossary here: ● SIMATIC NET Manual Collection or product DVD The DVD ships with certain SIMATIC NET products. ● On the Internet under the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 14
Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
Service - IEEE 802.11Q) and DSCP (Differentiated Services Code Point - RFC 2474) Layer 3 functions The following functions are only available on devices with routing functions: ● Static routing ● OSPF / OSPFv3 ● VRRP / VRRPv3 ● RIP / RIPng SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 16
Interface names with SCALANCE XM-400 ● Interfaces of the basic device The interfaces of the basic device SCALANCE XM-400 are called module 1. ● Interfaces of extenders The port extenders are called module 2 and module 3 starting from the basic device. The number of port extenders depends on the number of ports of the basic device.
One exception to this can be the IP configuration if it is set over DHCP and the DHCP server has not been reconfigured accordingly. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This makes an additional power cable unnecessary. PoE can be used with all PoE-compliant network components that have a maximum power consumption of max. 25.50 W. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 19
A Siemens power insert can also be used as the interface for the power input. Since a power insert supports a power supply of 24 VDC, it does not conform with IEEE 802.3af or IEEE 802.3at.
+ 10 m TP cord Table 2-3 Fitting connectors IE FC outlet RJ-45 IE FC RJ-45 modular out‐ 1000BaseT 10BaseT, 100BaseTX Yellow Green/white Orange Green White Orange/white Blue Orange Blue Blue/white Brown/white Brown SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Only endpoint of the communication Quality of service Type of Service (ToS) for The prioritization is specified in the header field "Traffic Class". prioritization Types of frame Broadcast, multicast, uni‐ Multicast, unicast, anycast cast SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 22
The DHCPv6 server delegates the distribution of IPv6 prefixes to the DHCPv6 client. The DHCPv6 client is also known as PD router. Resolution of IP addresses in ARP (Address Resolution NDP (Neighbor Discovery Protocol) hardware addresses Protocol) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
To find out whether two IP addresses belong to the same subnet, the two IP addresses and the subnet mask are ANDed bit by bit. If both logic operations have the save result, both IP addresses belong to the same subnet, for example, 141.120.246.210 and 141.120.252.108. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– To be able to assign an IP address to the IE switch with the PST, it must be possible to reach the device via Ethernet. – You will find the PST on the Internet pages of Siemens Industry Online Support under the entry ID 19440762 (http://support.automation.siemens.com/WW/view/en/...
To be able to use the RUGGEDCOM EXPLORER, RCDP (RUGGEDCOM Discovery Protocol) must be enabled on the device. You will find more information on the RUGGEDCOM EXPLORER here: – On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15391/man) –...
A link is, according to IPv6 terminology, a direct layer 3 connection within an IPv6 network. Neighbor Two network nodes are called neighbors when they are located on the same link. IPv6 interface SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 27
Example: MAC address = AA:BB:CC:DD:EE:FF OUI = AA:BB:CC NIC = DD:EE:FF EUI-64 = OUI + FFFE + NIC = AA:BB:CC:FF:FE:DD:EE:FF Scope Defines the range of the IPv6 address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The IPv6 prefix represents the subnet identifier. Prefixes and IPv6 addresses are specified in the same way as with the CIDR notation (Classless Inter-Domain Routing) for IPv4. Design IPv6 address / prefix length SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 29
IPv6 address: 2001:0db8:1234::1111/48 Prefix: 2001:0db8:1234::/48 Interface ID: ::1111 Entry and appearance The entry of IPv6 addresses is possible in the notations described above. IPv6 addresses are always shown in the hexadecimal notation. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 30
IP addresses 3.3 IPv6 addresses SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
DHCP pools IPv4 addresses managed by the DHCP server (dynamic + static) Relay agent information for DHCP DHCP static assignments per DHCP pool SNMPv1 trap recipient SNTP server NTP server SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 32
Multiple Spanning Tree instances Link aggregations or EtherChannels Ports in a link aggregation Static MAC addresses in the Forward Database (FDB) Multicast addresses without active GMRP Multicast addresses with active GMRP SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
OSPFv2 virtual links authentication keys (8 virtual links each with 5 keys) PIM multicast routes per device 1000 PIM components Rendezvous points Candidates for rendezvous points Static rendezvous points SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 34
● Source Port Min. ● Source Port Max. ● Dest. Port Min. ● Dest. Port Max. Per port and transmission direction (ingress/egress) you can use 8 comparators. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The management station sends data packets of the following type: ● GET Request for a data record from the SNMP agent ● GETNEXT Calls up the next data record. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 36
You can only transfer SNMPv3 users to a different device if you have created the users as migratable users. To create a migratable user the "SNMPv3 User Migration" function must be activated when you create the user. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● System Contact The RUGGEDCOM EXPLORER can run on every LAN-based MS Windows-PC. You will find more information on the RUGGEDCOM EXPLORER here: ● On the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15391/man) ● On the Internet pages of RUGGEDCOM products (http://w3.siemens.com/mcms/industrial-...
The end nodes on the networks must be checked to find out whether they can process this length / this frame type. If this is not the case, only frames of the standard length may be sent to these nodes. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 39
7 (highest) Network Control The prioritization of the data packets is possible only if there is a queue in the components in which they can buffer data packets with lower priority. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Devices within a community secondary PVLAN can communicate with each other directly via layer 2. The devices cannot communicate with devices in other communities of the PVLAN via layer 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
PCs. PC1 cannot communicate with any other PC. The PCs within a community secondary PVLAN can communicate with each other but not with the PCs in another secondary PVLAN. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"Switch-Port VLAN Trunk". Customer network A Customer network A VLAN ID VLAN ID Customer network B Customer network B Priority Priority Provider network Customer network C Customer network C untagged untagged SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
VLAN. On the RSPAN VLAN, the mirrored data traffic is not disturbed by other data. Frames addressed directly to the monitoring source switch cannot be mirrored on the RSPAN destination port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Function Extender BUS ANALYZER Agent XM-400 You can use the Function Extender BUS ANALYZER Agent XM-400 with the basic devices SCALANCE XM-400 as of firmware version 5.1. The function extender BUS ANALYZER Agent XM-400 is a modular network component with 4 internal monitor ports for port mirroring.
(3 x hello time), the port returns to the edge port status. ● Point-to-point (direct communication between two neighboring devices) By directly linking the devices, a status change (reconfiguration of the ports) can be made without any delays. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
In the ring, a master/slave device pair is configured and these monitor each other via their ring ports. If a fault occurs, the data traffic SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
IEC 62439‑2 Release 1.0 (2010‑02) Industrial communication networks ‑ High availability automation networks Part 2: Media Redundancy Protocol (MRP) The reconfiguration time after an interruption of the ring is a maximum of 200 ms. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 48
● The ring in which you want to use MRP may only consist of devices that support this function. These include, for example, some of the Industrial Ethernet SCALANCE X switches, some of the communications processors (CPs) for SIMATIC S7 and PG/PC or non-Siemens devices that support this function.
Page 49
– STEP 7: Set all the ports involved in the ring to "Automatic settings" in the "Options" tab of the properties dialog. – WBM: If you configure with Web Based Management, the ring ports are set automatically to autonegotiation. See also Configuration in STEP 7 (Page 50) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– For all other devices in the ring select "MRP Client" or "Automatic Redundancy Detection". ● You want to use MRP in a ring topology that also includes non-Siemens devices: – For exactly one device in the ring select the role "MRP Auto Manager".
Page 51
The MRP settings are still effective after a restart of the device or a power failure and hot restart as long as the power failure does not occur within 90 seconds after the configuration change. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 52
Reconfiguration only when the ring is open! The choice of role depends on the following use cases. ● You want to use MRP in a topology with one ring only with Siemens devices and without monitoring diagnostic interrupts: Assign all devices to the "mrpdomain‑1" domain and the role "Manager (Auto)".
Page 53
Technical basics 4.6 Redundancy mechanism ● You want to use MRP in a ring topology that also includes non-Siemens devices or you want to receive diagnostic interrupts relating to the MRP status from a device (see "Diagnostic interrupts"): – Assign precisely one device in the ring the role of "Manager (Auto)".
Page 54
If you enable this option, existing redundancy settings are retained and are not overwritten. The parameters in the "MRP configuration" box are then reset and grayed out. The entries then have no meaning. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
S7-1500 S7-1500 SCALANCE XB205-3 SCALANCE XB205-3 as standby master as standby slave 100 Mbit/s S7-400 SCALANCE SCALANCE X204-2 X308-2 SIMATIC S7-1200 Figure 4-3 Example of a redundant link between rings SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Link Check uses several intervals to be able to recognize sudden occurrences of errors as well as a continuous low error rate. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
To control and monitor, the Link Aggregation Control Layer (LACL) and the Link Aggregation Control Protocol (LACP) are used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The route is entered manually in the routing table. Enter the route in the routing table on the following pages. ● Layer 3 (IPv4) > Static Routes ● Layer 3 (IPv6) > Static Routes See also Static Routes (Page 351) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● VRRPv3 supports IPv4 and IPv6. Both can be configured and operated at the same time with VRRP3. You configure VRRPv3 in: IPv4: Layer 3 (IPv4 )> VRRPv3 (Page 372) IPv6: Layer 3 (IPv6 )> VRRPv3 (Page 422) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
At least one of the OSPF interfaces is assigned to the backbone area. ● Autonomous System Border Router (ASBR) One interface of the router is connected to a different AS, for example an AS that uses the routing protocol RIP. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 61
LSAs (Link State Advertisements). The LSAs are always sent from the router to the neighbor router. If there are changes in the network, LSAs are sent to all routers in the network. The information depends on the LSA type. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 62
NSSA ASBR. The LSA Type 7 is sent only within the NSSA. If the P bit in LSA Type 7 = 1, these LSAs are converted to LSA Type 5 by the ABR and sent to the backbone area. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 63
"down". The relevant entries are deleted. Updating the neighborhood database Once the neighborhood database is established, LSAs are sent to all routers in the network if there are changes in the topology. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
LSAs – Router LSA – Network LSA – Inter-area prefix LSA – Inter area router LSA – Intra area prefix LSA ● AS scope LSDB Contains the AS external LSA SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The routing table contains entries for all possible destinations. Each entry includes the distance to the destination and the first router on the route. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● In every subnet there is a designated router (DR). ● The DR must also be the IGMP querier. PIM network PIM operates in the sparse mode designed for networks with a low node density. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 67
PIM source specific multicast is a further variant of Sparse mode that manages without rendezvous points. Via IGMPv3, the recipient directly informs the router of the source and the multicast it would like to receive. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
In Network Address Translation (NAT) IP subnets are divided into "Inside" and "Outside". The division is from the perspective of a NAT interface. All networks reachable via the NAT interface SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 69
The actual IP address of PC1 (inside local) is implemented statically with NAT. For PC2, PC1 can be reached at the inside global address. Perspective Local Global Position Inside 192.168.16.150 10.0.0.7 Outside 10.0.0.10 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 70
If a device from the external network wants to use a service in the internal network, the translation list for the static address assignment needs to be configured. You configure NAPT in "Layer 3 (IPv4) > NAT > NAPT (Page 349)". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 71
NAT/NAPT and IP routing You can enable NAT/NAPT and IP routing at the same time. In this case, you need to regulate the reachability of internal addresses from external networks with ACL rules. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 72
Technical basics 4.9 NAT/NAPT SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Under "Check for newer versions of stored pages:", select "Automatically". ● If a firewall is used, the relevant ports must be opened. – For access using HTTP: TCP port 80 – For access using HTTPS: TCP port 443 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
2. In the address box of the Internet browser, enter the IP address or the URL of the device. If there is a problem-free connection to the device, the logon page of Web Based Management (WBM)is displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 75
There are two ways in which you can log on via HTTP. You either use the logon option in the center of the browser window or the logon option in the upper left area of the browser window. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 76
Internet browser. 2. Check the displayed certificate warning and confirm it if applicable. The logon page of Web Based Management appears. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 77
You need to repeat the password as confirmation. The password entries must match. Click the "Set Values" button to complete the action and activate the new password. Once you have logged in successfully, the start page appears. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The following areas are generally available on every WBM page: ● Selection area (1): Top area ● Display area (2): Top area ● Navigation area (3): Left-hand area ● Content area (4): Middle area SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 79
When you click this button, the help page of the currently selected menu item is opened in a new browser window. The help page contains a description of the content area. Under certain circumstances, options are described that are not available on the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 80
The submenus contain pages on which information is available or with which you can create configurations. These pages are always displayed in the content area. If you have created favorites, the navigation area is divided into two tabs: "Menu" and "Favorites". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 81
● Power Supply 1 / Power Supply 2 – Up Power supply 1 or 2 is applied. – Down Power supply 1 or 2 is not applied or is below the permitted voltage. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 82
On pages with a lot of data records the number of data records that can be displayed on a page is limited. Click the "Prev" button to page back through the data records. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
X.X = port in which the SFP module is inserted. – SlotX "X" = slot number: Module plugged into this slot. ● Name Shows the name of the device or module. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Identification and Maintenance data This page contains information about device-specific vendor and maintenance data such as the order number, serial number, version number etc. You cannot configure anything on this page. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 85
Shows the date created during configuration of the device with HW Config of STEP 7. ● Descriptor Shows the description created during configuration of the device with HW Config of STEP 7. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the IP address of the destination device. ● Media Type Shows the type of connection. – Dynamic The device recognized the address data automatically. – Static The addresses were entered as static addresses. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The device allows you to log occurring events, some of which you can specify on the page of the "System > Events" menu. This, for example, allows you to record when an authentication attempt failed or when the connection status of a port has changed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 88
If the system time is set, the date and time are also displayed at which the event occurred. ● Severity Sorts the entry into the categories above. ● Log Message Displays a brief description of the event that has occurred. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Errors of the "Cold/Warm Start" event can be deleted by a confirmation. The calculation of the time of an error always begins after the last system start. If there are no errors present, the fault LED switches off. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 90
● Fault Description Displays a brief description of the fault/error that has occurred. ● Clear Fault State If the "Clear Fault State" button is enabled, you can delete the fault. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
MSTP > General". The following values are possible: – '-' – STP – RSTP – MSTP ● Instance ID Shows the number of the instance. The parameter depends on the configured mode. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 92
– Root The port that provides the best route to the root bridge. – Master This port points to a root bridge located outside the MST region. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows how many VRRP packets containing an unsupported VRID were received. ● Version Errors Shows how many VRRP packets containing an invalid version number were received. ● Checksum Errors Shows how many VRRP packets containing an invalid checksum were received. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 95
Shows how many bad VRRP packets were received whose authentication type was not type 0. Type 0 means "no authentication". ● Address List Errors Shows how many bad VRRP packets were received whose address list does not match the locally configured list. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Interface to which the settings relate. ● VRID Shows the ID of the virtual router. Valid values are 1 ... 255. ● Type Shows the version of the IP protocol. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 97
Shows how many bad VRRPv3 packets were received whose address list does not match the locally configured list. ● Packet Length Errors Shows how many bad VRRPv3 packets were received whose length is not correct. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Ring redundancy Information on ring redundancy On this page, you obtain information about the status of the device in terms of ring redundancy. The text boxes on this page are read-only. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 99
Shows how often the device as redundancy manager switched to the active status, i.e. closed the ring. If the redundancy function is disabled or the device is an "HRP/MRP client" , the text "Redundancy Manager Disabled" appears. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The Standby tab shows the status of the standby function: Description of the displayed values The table has the following columns: ● Standby Ports Shows the standby port. ● Standby Name Standby Connection Name SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page shows the following information on the link check: ● The ports on which you can enable Link Check ● The current status ● The statistics of sent and received Link Check frames of the monitored connections. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 102
The function is enabled. Link Check has detected a fault on the monitored section and turned off the port. ● Frames in Shows how many Link Check test frames were received. ● Frames out Shows how many Link Check test frames were sent SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the number of all possible RX errors, refer to the tab "Packet Error". Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counters are reset by a restart. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You cannot configure anything on this page. The displayed values are transferred by RMON. On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You cannot configure anything on this page. The displayed values are transferred by RMON. On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The displayed values are transferred by RMON. On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 107
– Collisions Collisions that were detected. Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counters are reset by a restart. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Number of the sample ● Sample Time System up time at which the sample was taken. ● Unicast Number of received unicast frames. ● Multicast Number of received multicast frames. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This page shows the current content of the unicast filter table. This table lists the source addresses of unicast address frames. Entries can be made either dynamically when a node sends a frame to a port or statically by the user setting parameters. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The entries can be dynamic (the device has learned them) or static (the user has set them). Note The device does not learn any reserved multicast addresses, see also RFC 5771. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 111
Shows VLAN ID of the VLAN to which the MAC multicast address is assigned. ● MAC Address Shows the MAC multicast address that the device has learned or the user has configured. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
GMRP or IGMP/MLD. 5.3.10.2 IGMP Groups Status of the multicast filter table This table shows the multicast groups currently entered in the filter table, configured and joined. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
LLDP agent has received from connected devices. You set the interfaces via which the LLDP agent receives or sends information in the following section: "Layer 2 > LLDP". Figure 5-3 Information LLDP SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
With Fiber Monitoring, you can monitor optical links. The table shows the current status of the ports. You set the values to be monitored on the following page: "Layer 2 > FMP". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 115
Fiber monitoring is disabled. ● ok The value for the power loss of the optical link is within the defined limits. ● maint. req. Check the link. A warning is signaled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● Destination Network Shows the destination address of this route. ● Subnet Mask Shows the subnet mask of this route. ● Gateway Shows the gateway for this route. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● IP address Shows the IPv4 address of the OSPF interface ● Area ID Shows the area ID to which the OSPF interface belongs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the IPv4 address of the designated backup router for this OSPF interface. ● Events Shows the number of status changes of OSPF. 5.3.13.3 OSPFv2 Neighbors Overview This page shows the dynamically detected neighbor routers in the relevant networks. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 119
For virtual neighbor routers, this information is irrelevant. ● Hello suppr Shows the suppressed Hello packets to the neighbor router. This field normally displays "no". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● IP Address Shows the IPv4 address of the virtual neighbor router in this network. ● Router ID Shows the router ID of the virtual neighbor router. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 121
– yes: There are suppressed Hello packets. ● Hello Queue Shows the length of the queue with Hello packets still to be transmitted. ● Events Shows the number of status changes. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The link state database is the central database for managing all links within an area. It consists of the link state advertisements (LSAs). The most important data of these LSAs is shown on the this WBM page. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence number is incremented by one. 5.3.13.6 RIPv2 Statistics Overview This page shows the statistics of the RIP interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows how often the router has sent its routing table to its neighbor routers. 5.3.13.7 NAT Translations Overview This page displays the active NAT connections. Description of the displayed values SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This page shows the PIM interfaces. Description of the displayed values The table has the following columns: ● Interface Shows the PIM interface. ● Address Shows the IP address of the interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the PIM interface. The PIM routers are connected together via this interface. ● Neighbor Address Shows the IP address of the neighbor. ● DR Priority Shows the DR priority of the interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
(*,G) messages contain the group and the information to pass on the message in the direction of the RP. The route is via the RP. ● Incoming Interface Shows the interface via which the multicast will be received. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Depending on your selection not all columns are displayed in the table. The table has the following columns: ● Group Address Shows the address of the multicast group. ● Group Mask Shows the subnet mask that restricts the multicast band. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Candidate BSR Address Shows the interfaces of the device that are candidates for the BSR on the PIM router. ● Candidate BSR Priority Shows the priority of the BSR. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the multicast group. ● RP Shows the MSDP partner. ● Uptime Show the remaining time after which an entry is deleted from the SA cache if no SA cache updates are received. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the routing protocol from which the entry in the routing table originates. The following entries are possible: – connected: Connected routes – Static: Static routes – RIPng: Routes via RIPng – OSPFv3: Routes via OSPFv3 – other: Other routes SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The router is the backup router for the designated router. – S D. Router The Interface has started up. The router is neither a designated nor a designated backup router. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● Interface Displays the OSPFv3 interface via which the neighbor router can be reached. ● Router ID Shows the ID of the neighbor router. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 134
Shows the suppressed Hello packets to the neighbor router. This field normally displays "no". ● Hello Queue Shows the length of the queue with Hello packets still to be transmitted. ● Events Shows the number of status changes. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The database is complete and synchronized within the area. The routes can now be detected. Note Normal status If the partner router is a designated router or a designated backup router, the status is "full". Otherwise the status is "two-way". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the ID of the router that sent this LSA. ● Sequence Number Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence number is incremented by one. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
OSPFv3 Area-Scope LSDB Overview The Area-Scope LSDB is the central database for managing all links within an area. The most important data of the LSAs is shown on this page. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 138
Shows the ID of the router that sent this LSA. ● Sequence Number Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence number is incremented by one. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the ID of the router that sent this LSA. ● Sequence Number Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence number is incremented by one. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Unknown Commands Shows how many RIPng packets were received whose value in the "Commands" field of the RIPng header is unknown. Known values are 1 for requests and 2 for responses. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This page shows which IPv4 addresses were assigned to the devices by the DHCP server. Description ● IP Address Shows the IPv4 address assigned to the DHCP client. ● Pool ID Shows the number of the IPv4 address band. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 142
Click this button to go to the previous page. Drop-down list for page change From the drop-down list, select the page you want to go to. "Refresh" button Refreshes the display of the values in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the user that is assigned to the group. 5.3.17 Security 5.3.17.1 Overview Note The values displayed depend on the rights of the logged-on user. This page shows the security settings and the local and external user accounts. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 144
You configure the setting in "System > Configuration". – HTTP/HTTPS: Access to the WBM is possible with HTTP and HTTPS. – HTTPS: Access to the WBM is now only possible with HTTPS. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 145
"External User Accounts". If an entry exists, the user is logged SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"Information > Security > Roles". 5.3.17.2 Supported Function Rights Note The values displayed depend on the role of the logged-on user. The page shows the function rights available locally on the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This is a role that the device assigns internally when a user could not be authenticated. The user is denied access to the device. ● Description Shows a description of the role. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The WBM page contains the configuration overview of the access options of the device. Specify the services that access the device. With some services, there are further configuration pages on which more detailed settings can be made. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 149
Enable or disable the SMTP client. You can configure other settings in "System > SMTP Client". ● Syslog Client Enable or disable the Syslog client. You can configure other settings in "System > Syslog Client". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 150
> System Time > NTP Client". – PTP Client(SCALANCE XR528-6M and XR552-12M only) The system time is set via a PTP. You can configure other settings in "System > System Time > PTP Client". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 151
Steps in configuration 1. To use the required function, select the corresponding check box. 2. Select the options you require from the drop-down lists. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The system name is also displayed in the CLI input prompt. The number of characters in the CLI input prompt is limited. The system name is truncated after 16 characters. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The geographic coordinates can also be obtained using a GPS receiver. The geographic coordinates of these devices are normally displayed directly and only need to be entered in the input boxes of this page. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Manually configured DNS servers are each assigned an index from 1 to 3. Using DHCP the IE switch can learn 2 DNS servers with IPv4 addresses. Learned DNS servers are automatically assigned an index from 6 to 7. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 155
Internet. A maximum of three DNS servers can be configured. – All The device uses all available DNS servers. ● DNS Server Address Enter the IP address of the DNS server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
In this menu, there is a button with which you can restart the device and the option of resetting to the factory setting or reset the default settings of various profiles. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 157
The profiles can be used independently of the factory setting of the device. Description of the displayed boxes Note Note the effects of the individual functions described in the sections above. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This ZIP file stores all the configuration backups you have created. Debug This file contains information for Siemens Support. It is encrypted and can be sent by e-mail to Siemens Support without any security risk. DebugExt This file contains detailed information for Siemens Support.
Electronic Data Sheet (EDS) Electronic data sheets for describing devices in the EtherNet/IP mode Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. GSDML PROFINET information on the device properties HTTPSCert Default HTTPS certificates including key The preset and automatically created HTTPS certificates are self-signed.
Page 160
Configuring with Web Based Management 5.4 The "System" menu The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with previous firmware versions with/without PLUG inserted During the installation of a previous version, the configuration data can be lost. In this case, the device starts up with the factory settings after the firmware has been installed.
Page 161
With this button, you can delete files from the device. The button can only be enabled if this function is supported by the file type and the file exists on the device. Note Following a firmware update, delete the cache of your Internet browser. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
TFTP server or to load such data from an external file from the TFTP server to the devices. This means, for example, that you can also load new firmware from a file located on a TFTP server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 163
Configuring with Web Based Management 5.4 The "System" menu Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with previous firmware versions with/without PLUG inserted During the installation of a previous version, the configuration data can be lost. In this case, the device starts up with the factory settings after the firmware has been installed.
Page 164
69 to your own requirements. The table has the following columns: ● Type Shows the file type. ● Description Shows the short description of the file type. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 165
3. If individual settings are necessary for specific devices, these must be made online on the relevant device. Note that the configuration data is coded when it is saved. This means that you cannot edit the files with a text editor. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Procedure 1. Enter the password in "Password". 2. To confirm the password, enter the password again in "Password Confirmation". 3. Select the "Enabled" option. 4. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you specify how a device reacts to system events. By enabling the appropriate options, you specify how the device reacts to events. To enable or disable the options, click the relevant check boxes of the columns. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 168
● Syslog The device writes an entry to the system log server. This is only possible if the system log server is set up and the "Syslog client" function is enabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 169
– PoE State Change The status of PoE has changed. – FMP Status Change The value of the received power or the power loss has exceeded or fallen below a certain limit. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Entry of system events in the log table ● Syslog Sending of system event messages to a Syslog server. Select the required level from the drop-down lists of the second table column. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
When an e-mail error message is received, the WBM can be started by the Internet browser using the identification of the sender to read out further diagnostics information. On this page, you can configure up to three SMTP servers and the corresponding e-mail addresses. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 172
Depending on the properties and configuration of the SMTP server, it may be necessary to adapt the "Sender E-Mail Address” input box for the e-mails. Check with the administrator of the SMTP server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Identification is based on the device name. If the device name is 255 characters long, the last character is not used for identification. – via PROFINET Name of Station The identification is made using the PROFINET device name. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
During configuration make sure that the selection of the pool based on the criteria named is possible. If the criteria match several pools, only one pool is selected. The other pools for which the same criteria match are never selected. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 175
If you deactivate or delete an IPv4 address band or turn the DHCP server off and on again, the DHCP server assignments are deleted see "Information > DHCP Server". Requirement The connected devices are configured so that they obtain the IP address from a DHCP server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 176
● Lower IP Address Enter the IPv4 address that specifies the start of the dynamic IPv4 address band. The IPv4 address must be within the network address range you configured for "Subnet". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 177
In the "DHCP Server" tab the boxes "Subnet", "Lower IP Address" and "Upper IP Address" are filled accordingly. – Configure the lease time in the "DHCP Server" tab. 5. Make the settings you require for the pool in the other DHCP tabs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
With this setting, in the "Port Range" tab no ports or more than one port are selected. If you select the setting "Not Selected", all ports in the "Port Range" tab are disabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This table contains the following columns: ● Pool ID Shows the number of the IPv4 address band. A line is created for every address band. ● Interface Shows the assigned IP interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
1 the subnet mask is set automatically that you entered for the address band in "DHCP Server". With the DHCP option 3, you can set the internal IPv4 address of the DHCP server as a DHCP parameter using a check box. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 181
● Pool ID Shows the number of the IPv4 address band. ● Option Code Shows the number of the DHCP option. ● Description Shows a description of the DHCP option. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 182
2. Enter the option code. 3. Click the "Create" button. 4. Enter a value. 5. If applicable for option 3 enable the "Use Interface IP" check box. 6. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the circuit ID. The table has the following columns: ● Select Select the check box in the row to be deleted. ● Pool ID Shows the number of the IPv4 address band. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
2. Click the "Delete" button. The entry is deleted. 5.4.9.7 Static Leases On this page you define that DHCP clients are assigned a preset IPv4 address depending on their client ID or MAC address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 185
1. Enable the "Select" check box in the row to be deleted. Repeat this for all entries you want to delete. 2. Click the "Delete" button. The entry is deleted. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
5.4 The "System" menu 5.4.10 SNMP 5.4.10.1 General Configuration of SNMP On this page, you make the basic settings for SNMP. Enable the check boxes according to the function you want to use. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 187
Enable or disable the sending of SNMPv1 traps (alarm frames). On the "Trap" tab, specify the IP addresses of the devices to which SNMPv1 traps will be sent. ● SNMPv1/v2c Trap Community String Enter the community string for sending SNMPv1/v2c messages. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 188
4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String" input box. 5. If necessary, enable the SNMPv3 User Migration. 6. Click the "Set Values" button. See also SNMP (Page 35) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
1. In "Trap Receiver Address", enter the IP address, the FQDN or the host name of the station to which the device will send traps. 2. Click the "Create" button to create a new trap entry. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– no Auth/no Priv No authentication enabled / no encryption enabled. – Auth/no Priv Authentication enabled / no encryption enabled. – Auth/Priv Authentication enabled / encryption enabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 191
If you want to change the group name or the security level, you will need to delete the group and recreate it and reconfigure it with the new name. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The user-based security model works with the concept of the user name; in other words, a user ID is added to every frame. This user name and the applicable security settings are checked by both the sender and recipient. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 193
Length of the password As an important measure to maximize security, we recommend that the password has a minimum length of 6 characters and that it contains special characters, uppercase/ lowercase letters, numbers. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
There are different methods that can be used to set the system time of the device. Only one method can be active at any one time. If one method is activated, the previously activated method is automatically deactivated. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Click the button to use the time setting of the PC. ● Last Synchronization Time Shows when the last time-of-day synchronization took place. If no time-of-day synchronization was possible, the box displays "Date/time not set". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 196
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY HH:MM:SS". 4. Click the "Set Values" button. The date and time are adopted and "Manual" is entered in "Last Synchronization Mechanism" box. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
With an entry of the type "Recurring", the period in which daylight saving time is active is displayed consisting of week, day, month and time of day. With an entry of the type "Date" a "-" is displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 198
– Day (for start and end date) 7. Click the "Set Values" button. Deleting an entry 1. Enable "Select" in the row to be deleted. 2. Click the "Delete" button. The entry is deleted. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This setting is suitable for regions in which the daylight saving time always begins or ends on a certain weekday. ● Name Enter a name for the entry. The name can be a maximum of 16 characters long. Settings with "Date" selected SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 200
Enter the following values for the end of daylight saving time: – Day Specify the day. – Hour Specify the hour. – Month Specify the month. Settings with "Recurring" selected SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 201
Specify the hour. – Month Specify the month. – Week Specify the week. You can select the first to fourth or the last week of the month. – Day Specify the weekday. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the current date and current normal time received by the IE switch. If you specify a time zone, the time information is adapted accordingly. ● Last Synchronization Time Shows when the last time-of-day synchronization took place. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 203
In this mode, IPv4 and IPv6 addresses are supported. ● Poll Interval[s] Here, enter the interval between two-time queries. In this box, you enter the query interval in seconds. Possible values are 16 to 16284 seconds. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 204
The port can only be modified if the IPv4 address or the FQDN name of the SNTP server is entered. 8. Click the "Set Values" button to transfer your changes to the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the current date and current normal time received by the IE switch. If you specify a time zone, the time information is adapted accordingly. ● Last Synchronization Time Shows when the last time-of-day synchronization took place. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 206
– 1025 to 36564 ● Poll Interval[s] Here, enter the interval between two-time queries. In this box, you enter the query interval in seconds. Possible values are 64 to 1024 seconds. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the following boxes: ● SIMATIC Time Client Select this check box to enable the device as a SIMATIC time client. ● Current System Time Shows the current system time. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The following devices support time-of-day synchronization using PTP: ● SCALANCE XR528-6M ● SCALANCE XR552-12M Automatic time-of-day setting with PTP If you require time-of-day synchronization using PTP, you can make the relevant settings here. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 209
Procedure 1. Click the "PTP Client" check box to enable the automatic time setting using PTP. 2. Specify the a time zone, if applicable. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You will find a detailed description of the individual functions available with the buttons in the device operating instructions. On this page, the functionality of the SELECT/SET button can be restricted or fully disabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 211
Enable or disable the function "Define fault mask via the LED display" with the SELECT/ SET button. Steps in configuration 1. To use the required functionality, select the corresponding check box. 2. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the IP address, the FQDN (Fully Qualified Domain Name) or the host name of the Syslog server. ● Server Port Enter the port of the Syslog server being used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 213
2. Create a new entry. Deleting an entry 1. Select the check box in the row to be deleted. 2. Click the "Delete" button. All selected entries are deleted and the display is refreshed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the type of the port. The following types are possible: – Router port – Switch Port VLAN Hybrid – Switch-Port VLAN Trunk – Switch Port VLAN Host – Switch-Port PVLAN Promiscuous – Switch Port VLAN Access SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 215
Shows whether the automatic configuration is enabled or disabled. ● Flow Ctrl. Type Shows whether flow control is enabled or disabled for the port. ● Flow Ctrl. Shows whether flow control is working on this port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 216
In the connection status "down", the displayed transmission parameters do not match the actual values of the combo port. In the connection status "up", the correct values are displayed. Initial situation SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
With 1 Gbps pluggable transceivers ● Actual response: Mode: 1G HD ● Expected response: Mode: 1G FD 5.4.15.2 Configuration Configuring ports With this page, you can configure all the ports of the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 218
10 Mbps, 100 Mbps, 1000 Mbps or 10 Gbps. As the transmission mode, you can configure full duplex (FD) or half duplex (HD). ● Negotiation Shows whether the automatic configuration of the connection to the partner port is enabled or disabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 219
Connect devices to promiscuous ports that are intended to communicate with all devices of the PVLAN. – Switch Port VLAN Access Access ports belong to a provider switch that supports the function Q-in-Q VLAN-Tunnel. Connect a customer network to access ports. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 220
You have configured the status "disabled" or "Link down" for the port or the port has no connection. – not present With modular devices, this status is displayed when, for example, no media module is inserted. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 221
The status “Link down" is configured for the port, see "System > Ports > Configuration". – Standby Standby redundancy is enabled on the device. The port is a standby port with the status "Passive". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
A fault causes the signaling contact to trigger and the fault LED on the device to light up and, depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
A fault causes the signaling contact to trigger and the fault LED on the device to light up and, depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 224
1. Select the required setting from the drop-down list of the "Setting"column. 2. Click the "Copy to table" button. The setting is adopted for all ports of table 2. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enable or disable connection monitoring. If the redundancy of the connection is lost, an error is signaled. 5.4.17 PROFINET Settings for PROFINET On this page, you configure the mode of PROFINET. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 226
Following this, the device can only be accessed via the serial interface, using the Primary Setup Tool or using DHCP. With the appropriate attachment, a previously correctly configured device can cause circulating frames after the reset and therefore the failure of the data traffic. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Configuring with Web Based Management 5.4 The "System" menu 5.4.18 EtherNet/IP EtherNet Industrial Protocol (EtherNet/IP) On this page, you configure the mode of EtherNet/IP. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The device checks whether or not a PLUG is present at one second intervals. If it is detected that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the device, the device changes to a defined error state following the restart. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 229
This allows you to return to the previous, more up-to-date firmware without any loss of configuration data. If the original configuration on the PLUG is no longer required, the PLUG can be deleted or rewritten manually using "System > PLUG". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 230
There is no PLUG inserted. Functions are configured on the device for which a license is required. ● Device Group Shows the SIMATIC NET product line that used the C-PLUG or KEY-PLUG previously. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 231
The configuration in the internal flash memory of the device is copied to the PLUG. – Erase PLUG to factory default Deletes all data from the C-PLUG and triggers low-level formatting. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
PLUG also contains a license that enables certain functions of your SIMATIC NET device. This page provides detailed information about the license on the KEY-PLUG. In this example, the KEY-PLUG contains the data for enabling the layer 3 functions of the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 233
The displayed software version corresponds to the version in which the configuration was last changed. With the "NOT ACCEPTED" status, further information on the cause of the problem is displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the following boxes: ● Destination Address Enter the IPV4, IPv6 address or the FQDN (Fully Qualified Domain Name) of the device. ● Repeat Enter the number of ping requests. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you see information about the power that the IE switch supplies with PoE. The SCALANCE XR-500 represents a PSE (Power Sourcing Equipment). With the SCALANCE XM-400, each group of four ports with PoE capability is known as a PSE. The displayed values apply only to the corresponding PSE.
Page 236
As soon as the power being used by the end devices exceeds the percentage shown here, an event is triggered. Power over Ethernet with SCALANCE XM-400 With a SCALANCE XM-400, you can use the "Power over Ethernet" function via the port extender PE408PoE. PoE power supply The connection of the PoE power supply is external.
Page 237
2, and there is a PE408PoE in slot 3, the PSE units in slot 3 still have the indexes 3 and Figure 5-9 SCALANCE XM-400 with 2 port extenders (1 port extender without PoE and 1 PE408PoE) With a SCALANCE XM416-4C with which you can only connect one port extender, the indexes of the PSE units are 1 and 2.
255 characters. ● Use Custom Maximum Power Select whether the custom maximum power is used. If "No Change" is selected, the entry in table 2 remains unchanged. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 239
– If the user-defined power is below the class of the connected device, the lowest value of the class is used. If the power consumption of the connected device exceeds the defined or used maximum power, the connected device is turned off. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If, however, there is a data connection to the port to be tested, this is briefly interrupted. Automatic re-establishment of the connection can fail and then needs to be done manually. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 241
Pair 3 = pin 3-6 Pair 4 = pin 7-8 ● Status Displays the status of the cable. ● Distance [m] Displays the distance to the cable end, cable break, or short-circuit. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The values are shown in the following boxes: ● Name Shows the name of the interface. ● Model Shows the type of interface. ● Revision Shows the hardware version of the SFP. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The created backups are saved in the file type "ConfigPackBackup". On the "System > Load&Save > HTTP/TFTP > " page you can save configuration backups on your client PC or load them from there. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 244
The current configuration is saved as a configuration backup. Saving the backup may take some time. A new row is created for the backup. The size of the backup is displayed and subtracted from the available memory space. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enable or disable subnet-based VLAN. Other settings in "Layer 2 > VLAN". ● Dynamic MAC Aging Enable or disable the "Aging" mechanism. You can configure other settings in "Layer 2 > Dynamic MAC Aging". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 246
If you have enabled the "Ring with RSTP" option, the following ports must not be included in the spanning tree: ● Ring ports ● Standby ports ● Standby coupling ports SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 247
– STP Enabled Spanning Tree Protocol. Typical reconfiguration times with spanning tree are between 20 and 30 seconds. You can configure other settings in "Layer 2 > Spanning Tree". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 248
GMRP and IGMP cannot operate at the same time. ● GVRP Enable or disable "GVRP" (GARP VLAN Registration Protocol). You can configure other settings in "Layer 2 > VLAN > GVRP". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
PTP message. You will find other settings in "Layer 2 > PTP" 5.5.2 5.5.2.1 CoS queue mapping CoS queue Here, CoS priorities are assigned to certain queues (Traffic Queues). SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 250
● CoS 7 → Queue 8 Steps in configuration 1. For each value in the "CoS" column, select the forwarding queue from the "Queue" drop- down list. 2. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– Trust DSCP – Trust COS-DSCP – No Change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 253
If it contains a VLAN tag, the switch sorts it into a queue according to this prioritization. If the frame contains neither a DSCP prioritization nor a VLAN tag, the switch sorts the frame into a queue according to the prioritization of the receiving port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Specify the data rate for all outgoing frames. If "No Change" is entered, the entry in the table remains unchanged ● Copy to table If you click the button, the settings are adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 255
2. To use the limitation for the incoming frames, select the check box in the row. For outgoing frames, the value in the "Egress Rate" column is used. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
VLANs involved. An example of a static configuration is the assignment of the multicast groups in certain VLANs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 257
● Private VLAN Type Shows the type of the PVLAN. ● Primary VLAN ID , With secondary PVLANs shows the ID of the corresponding primary PVLAN. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 258
The port is an untagged member of the VLAN, but the VLAN is not configured as a port VLAN. Frames sent in this VLAN are forwarded without the VLAN tag. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
A different device, can, for example be an end device or a switch. The device can also send GVRP frames via this port. On this page, you can enable each port for GVRP functionality. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 260
Shows the available ports. The port is made up of the module number and the port number, for example port 0.1 is module 0, port 1. ● Setting Enable or disable the sending GVRP frames. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select the setting in the drop-down list. If "No Change" is selected, the entry in table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 262
1. In the row of the port to be configured, click on the relevant cell in the table to configure it. 2. Enter the values to be set in the input boxes as follows. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
A few examples are shown below: – PROFINET: 88:92 – IP: 08:00 – Novell: 81:37 – netbios: f0:f0 – appletalk: 80:9b ● Group ID Enter the ID of the group. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
3. Click the "Delete" button. 4. Click the "Set Values" button. 5.5.4.5 Protocol-based VLAN port Introduction On this page, you specify which protocol and which VLAN is assigned to the individual port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 265
2. Select the group ID from the "Group Identifier" drop-down list. 3. Click the "Create" button. A new entry is generated in the table. 4. Specify the VLAN ID in " VLAN ID". 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Select Select the row you want to delete. ● Port All available ports and the link aggregations are displayed. ● Subnet Address Shows the subnet address assigned to the port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the following boxes: ● Port Select the port in the drop-down list. All available ports and the link aggregations can be selected. ● Prefix Address Enter the IPv6 address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 268
3. Enter the prefix length in "Prefix Length". 4. Select the VLAN ID from the "VLAN ID" drop down list. 5. Click the "Create" button. A new entry is generated in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
2. The secondary PVLAN has a specific VLAN ID. ● Primary VLAN ID For secondary PVLANs select the VLAN ID of the primary PVLAN. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Configure the IP interface assignment for all functions for which an end device needs to communicate from the secondary PVLAN via the IP interface of the primary PVLAN. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 271
Shows the secondary VLAN-ID of the secondary PVLAN from which the IP interface of the primary PVLAN is reachable. Steps in configuration 1. Create an IP interface for the primary PVLAN. 2. Select the primary PVLAN with an IP interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Disables the Q-in-Q VLAN tunnel function on all ports. – No Change Table 2 remains unchanged. ● Copy to Table If you click the button, the settings are adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 273
16.Change to the page "System > Ports > Configuration" 17.Select the required port. 18.Select the Port Type "Switch-Port PVLAN Access". 19.Click the "Set Values" button. 20.Change to the page "Layer 2 > Provider-Bridge > Tunnel-Ports". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If the maximum data rate of the mirrored port is higher than that of the monitor port, data may be lost and the monitor port no longer reflects the data traffic at the mirrored port. Several ports can be mirrored to one monitor port at the same time. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 275
Configuring with Web Based Management 5.5 The "Layer 2" menu Settings SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 276
The table for the basic settings contains the following boxes: ● Select Select the row you want to delete. ● Session ID The Session ID is assigned automatically when a new entry is created. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 277
ANALYZER Agent XM-400 as destination ports. Function extender BUS ANALYZER Agent XM-400 supports port-based, VLAN-based, MAC ACL-based and IP ACL-based mirroring. ● RSPAN Enable or disable RSPAN for a session. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 278
2. Create a mirroring session. 3. Select the "RSPAN VLAN ID". 4. Enable the check box in the "RSPAN" column. 5. Click the "Set Values" button to save the selected settings. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Ingress Mirroring Enable or disable listening in on incoming packets at the required port. ● Egress Mirroring Enable or disable listening in on outgoing packets at the required port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select the session you want to monitor. Only one session is possible. ● VLAN ID Enter the VLAN ID in the "VLAN ID" input box. Range of values: 1 ... 4094 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You configure the settings in "Security > MAC ACL > Ingress Rules". ● Source MAC Shows the MAC address of the sender. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You configure the settings in "Security > IP ACL > Ingress Rules". ● Source IP Shows the IPv4 address of the destination device. ● Source Subnet Mask Shows the subnet mask of the sender. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the time in seconds. After this time, a learned address is deleted if the device does not receive any further frames from this sender address. Range of values: 10 - 630 (seconds) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● The factory setting defines MSTP as the redundancy method. ● With SCALANCE XM-400, the factory setting defines ports P1.1 and P1.2 as ring ports. ● With SCALANCE XR-500, the factory setting defines ports P0.1 and P0.2 as ring ports.
Page 285
The ring port you select in the left-hand drop-down menu is the "Isolated Port" in HRP. With MRP when the link is established, it is decided which port will become the "Isolated Port". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 286
5. Change the cable connections. 6. Change to the page "Layer 2 > Spanning Tree > CIST Port". 7. Enable the ports in the spanning tree that are no longer ring ports. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Standby master coupling with an optical 100 Mbps connection While the coupling partner of a standby master with an optical 100 Mbps connection starts up again, physically disconnect the connection between the standby master and its coupling partner. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 288
Here, enter the name for the standby connection. This must be identical to the name entered on the standby partner. You can select any name to suit your purposes, however, you can only use the name for one pair of devices in the entire network. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 289
Multiple standby connections can, for example, result due to configuration errors if different standby connection names were assigned to the standby master and standby slave. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Link Check for the two connection partners connected to a line. 2. To ensure an error-free connection, wait 1 min. before you enable Link Check for the next connection. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 291
Disabling Link Check Follow the steps below to deactivate the monitoring of a ring port: 1. Deactivate the appropriate check box in the "Setting" column. 2. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– MSTP Steps in configuration 1. Select the "Spanning Tree" check box. 2. From the "Protocol Compatibility" drop-down list, select the type of compatibility. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The value for the bridge priority is a whole multiple of 4096. Range of values: 0 - 61440 ● Bridge Address / Root Address The bridge address shows the MAC address of the device and the root address shows the MAC address of the root bridge. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 294
Enter the name of the MSTP region to which this device belongs. As default, the MAC address of the device is entered here. This value must be the same on all devices that belong to the same MSTP region. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
MSTP-CIST port configuration When the page is called, the table displays the current status of the configuration of the port parameters. To configure them, click the relevant cells in the port table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 296
The default is 128. ● Cost Calc. Enter the path cost calculation. If you enter the value "0" here, the automatically calculated value is displayed in the "Path costs" box. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 297
Following the reconfiguration time, the port is active in the network; it receives and forwards data frames. ● Fwd. Trans Specifies the number of changes from the "Discarding" status to the "Forwarding" status. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 298
With an end device, a switch can change over the port faster without taking into account spanning tree frames. If a spanning tree frame is received despite this setting, the port automatically changes to the "Disabled" setting. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 299
1. In the input cells of the table row, enter the values of the port you are configuring. 2. From the drop-down lists of the cells of the table row, select the values of the port you are configuring. 3. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● VLAN ID Enter the VLAN ID. Here, you can also specify ranges with Start ID, "-", End ID. Several ranges or IDs are separated by ",". Permitted values: 1- 4094 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you set the parameters for the ports of the configured multiple spanning tree instances. Description of the displayed boxes The page contains the following box: ● MSTP Instance ID In the drop-down list, select the ID of the MSTP instance. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 302
Typical values for rapid spanning tree are as follows: – 10,000 Mbps = 2,000 – 1000 Mbps = 20,000 – 100 Mbps = 200,000 – 10 Mbps = 2,000,000 The values can, however, also be set individually. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
2. From the drop-down lists of the cells of the table row, select the values of the port you are configuring. 3. Click the "Set Values" button. 5.5.10.6 Enhanced Passive Listening Compatibility Enabling the function On this page, you can enable passive listening compatibility. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
With the "Loop detection" function, you specify the ports for which loop detection will be activated. The ports involved send special test frames - the loop detection frames. If these frames are sent back to the device, there is a loop. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 305
● Interval [ms] / Threshold value / Timeout [s] / Remote reaction / Local reaction Make the required settings. ● Copy to table If you click the button, the setting is adopted for all ports of table 2 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 306
This box shows whether loop detection is enabled or disabled for this port. ● Source Port Shows the receiving port of the loop detection frame that triggered the last reaction. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If the port in the link aggregation becomes active, individual port configurations such as DCP forwarding are overwritten with the configured values of the link aggregation. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 308
The distribution is based on a combination of the destination and source MAC address. – Destination&Source IP MAC The distribution is based on a combination of the destination and source IP and MAC address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 309
Basics prior to configuration 1. First, identify the ports you want to put together to form a link aggregation between the devices. 2. Configure the link aggregation on the devices. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
VLAN associated with the TIA interface. All the ports of the device are displayed on this page. After each displayed port, there is a drop- down list for function selection. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 311
Steps in configuration 1. From the options in the drop-down list in the row, select which ports should support sending DCP frames. 2. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The device compares the value it has received for the transmit power with the actually received power. The difference between SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 314
Specify the value at which you are informed of the deterioration of the received power by a message of the severity level "Critical" If you enter the value "0", the received power is not monitored. The default value depends on the relevant transceiver. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
5.5.16 Unicast 5.5.16.1 Filtering Address filtering This table shows the unicast addresses entered statically by the user during parameter assignment. On this page, you also define the static unicast filters. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 316
Shows the port via which the node with the specified address can be reached. Frames received by the device whose destination address matches this address will be forwarded to this port. Note You can only specify one port for unicast addresses. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"Start learning" function and the "Stop learning" function. To enter all connected nodes automatically, there is a function for automatic learning (see "Layer 2 > Unicast > Learning"). SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 318
Steps in configuration Enabling access control for an individual port 1. Select the check box in the relevant row in table 2. 2. To apply the changes, click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The device now enters the addresses of connected devices until you stop the function. 2. Click the "Stop learning" button to stop the learning function. The button is once again replaced by the "Start learning" button. The learned entries are stored. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Blocking of unicast frames is disabled. – No change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The "Multicast" menu item, shows the multicast frames currently entered in the filter table and their destination ports that the user set in the parameters (static). SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 322
Here, the VLAN ID of the VLAN is displayed to which the MAC multicast address of this row is assigned. ● MAC address Here, the multicast address is displayed that the device has learned or the user has configured. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 323
1. Select the check box in the row to be deleted. 2. Click the "Delete" button. The row is deleted from the display and from the memory of the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If a different IGMP querier is used, the value of the "IGMP Snooping Aging Time" should be at least twice as long as the query interval. Description of the displayed boxes SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
GMRP frames. For GMRP to work, you need to enable the function globally and on the ports. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 326
2. In the "Setting" drop-down list, select the "Enabled" entry. 3. Click the "Copy to table" button. The check box is enabled for all ports in table 2. 4. To apply the changes, click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Table 2 has the following columns: ● Port All available ports are listed in this column. Unavailable ports are not displayed. ● Setting Enable or disable the blocking of multicast frames. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
MLD are deleted from the address table if they are not updated by a new MLD packet. This applies to all VLANS; a VLAN-specific configuration is not possible. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 329
The function is disabled. – No Change Table 2 remains unchanged. ● Copy to Table If you click the button, the settings are adopted for all ports of table 2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Some communication protocols work only with the support of broadcast. In these cases, blocking can lead to loss of data communication. Block broadcast only when you are sure that you do not need it. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 331
Enabling the blocking of broadcast frames for an individual port 1. Select the check box in the relevant row in table 2. 2. To apply the changes, click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
HRP, standby linking of rings, MRP and RSTP. The following sections describe the configuration options of Web Based Management. 1588 Configuration On this page, you specify how the device will process PTP messages. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Domain Number Enter the domain number for the device here. The device ignores PTP messages with a different domain number. A SCALANCE device can only be assigned to one synchronization domain. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select the required setting. If "No Change" is selected, the entry in table 2 remains unchanged. ● Transport Mechanism The following settings are possible: – Ethernet – UDP IPv4 – No Change If "No Change" is selected, the entry in table 2 remains unchanged. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page you can specify the ports for which RMON statistics are displayed. The RMON statistics are shown on the page “Information > Ethernet Statistics” in “Packet Size”, “Frame Type” and “Packet Error” tabs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 336
Shows the ports for which statistics will be displayed. Steps in configuration Enabling the function Select the "RMON" check box. Click the "Set Values" button. The "RMON" function is enabled. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you can specify whether or not samples of the statistics are saved for a port. You can specify how many entries should be saved and at which intervals samples should be taken. Settings SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 338
3. Click the "Copy to Table" button. The settings are adopted for all ports of table 2. 4. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● OSPF (only available with devices with a layer 3 license) Enable or disable routing using OSPF. To use OSPF, first enable the "Routing" function. You can configure other settings in "Layer 3 (IPv4) > OSPF". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"Configuration" tab. Description of the displayed values The page contains the following boxes: ● Interface Select the interface on which you want to configure another subnet. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 341
– Static The IPv4 address is static. You enter the settings in "IP Address" and "Subnet Mask". – Dynamic (DHCP) The device obtains a dynamic IPv4 address from a DHCPv4 server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 342
2. If appropriate select the "loopback" property. 3. Click the "Create" button. A new row is inserted in the table. 4. Click the "Set Values" button. Configure the subnet on the "Configuration" tab. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the IPv4 address of the interface. The IPv4 addresses must not be used more than once. ● Subnet Mask Enter the subnet mask of the subnet you are creating. Subnets on different interfaces must not overlap. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 344
3. Enter the IPv4 address of the subnet in the "IP Address" column. 4. Enter the subnet mask belonging to the IPv4 address in the "Subnet Mask" column 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the required aging time for UDP connections. UDP connections are stored until no data exchange has taken place for the set period. Depending on the cyclic check when the Idle Timeout has elapsed, the connections are deleted from the table "NAT translations". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 346
2. Select the required IP interface. 3. Enable NAT/NAPT for the selected IP interface. 4. Click the "Set Values" button. 5. Make the settings you require for NAT/NAPT in the NAT/NAPT tabs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Inside Local Address Shows the actual address of the device that should be reachable from external. ● Inside Global Address Shows the address at which the device can be reached from external. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the start address for the dynamic assignment of addresses at which devices will be reachable from external. ● Inside Local Address Mask Enter the address mask of the external subnet. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
3. In "Inside Global Address Mask" enter the address mask of the external subnet. 5.6.3.4 NAPT On this WBM page, you configure static port translations. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 350
Shows the end port that will be assigned to the inside local address. ● Protocol Shows the protocol for which the port translation is valid. ● Inside Global Address Shows the address at which the device can be reached from external. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the following boxes: ● Destination Network Enter the network address of the destination that can be reached via this route. ● Subnet Mask Enter the corresponding subnet mask. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 352
3. Enter the gateway in the "Gateway" input box. 4. Enter the weighting of the route in "Administrative Distance". 5. Click the "Create" button. A new entry is generated in the table. 6. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter a number for the route map. You can create several route maps with the same name but with different sequence numbers. The sequence numbers then specify the order in which the route maps are processed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you specify whether or not the routing information for a route map is filtered according to interfaces, metric or tags. Settings Figure 5-11 Filtering route maps and metric SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 355
This box is active only if you have selected the "Metric" entry in the "Type" drop-down list. ● Tag Enter a value for the tag. This box is active only if you have selected the entry "Tag in the "Type" drop-down list. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the selected interface or the value of the metric or of the tag. 5.6.5.3 Destination Match On this page, you specify whether or not the routing information for a route map is filtered based on the destination IPv4 address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Next Hop Match On this page, you specify whether or not the filtering for a route map will be based on the router to which the routing information is sent next. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If, for example, you have filtered based on a certain metric, you can change the value of the metric here. The routing information is then forwarded with the new value. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
ID and a remote ID. You can specify up to 4 DHCP servers for the DHCP relay agent. If a DHCP server is unreachable, the device can switch to a different DHCP server. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 360
Steps in configuration 1. Enter the IPv4 address of the DHCP server in the "Server IP Address" input box. 2. Click the "Create" button. A new entry is generated in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
ID. ● Circuit ID Receive VLAN ID Enable or disable the check box. If you enable the check box, the VLAN ID is added to the generated circuit ID. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 362
If you use "Free Text", you can enter the device name as the device identifier in "Remote ID". ● Remote ID Enter the device name. The box can only be edited if you select the entry "Free Text" for "Remote ID Type". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 363
The IPv4 address is used as the device ID. – MAC address The MAC address is used as the device ID. – Free Text Enter the device ID in "Remote ID". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Select the "VRRP" check box to configure VRRP. ● Simultaneous operation of VRRP and VRRPv3 is not possible. ● You can only use VRRP in conjunction with VLAN interfaces. Router ports are not supported. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 365
The router is the backup router. If the master router fails, the backup router takes over the tasks of the master router. – Initialize The virtual router has just been turned on. It will soon change to the "Master" or "Backup" state. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 366
6. Select the "VRID Tracking" check box to monitor the VRID. 7. Click the "Set Values" button. To configure the virtual router, click on the "Configuration" tab. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If you configure more than one subnet on the VLAN and you want a specific IPv4 address to be used as the source address for VRRP packets, select the IPv4 address from the drop- down list. Otherwise, the numerically lowest IPv4 address will be used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 368
6. Select the "Preempt lower priority Master" check box. 7. Select a track ID. 8. Value by which the priority of the VRRP interface will be reduced 9. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you can create, modify or delete the IPv4 addresses to be monitored. A maximum of 10 IPv4 addresses can be monitored by a virtual router. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
When the link of a monitored interface changes from "up" to "down", the priority of the assigned VRRP interface is reduced. You configure the value by which the priority is reduced on the page "Layer 3 > VRRP/VRRPv3 > Configuration". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 371
The table has the following columns: ● Select Select the check box in the row to be deleted. ● Track ID Shows the track ID. ● Interface Shows the interface that is being monitored. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Simultaneous operation of VRRP and VRRPv3 is not possible. ● Select the "VRRPv3" check box to configure VRRPv3. ● You can use VRRPv3 on VLAN interfaces. Router ports are not supported. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 373
The router is the backup router. If the master router fails, the backup router takes over the tasks of the master router. – Initialize The virtual router has just been turned on. It will soon change to the "Master" or "Backup" status. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 374
6. Select the "VRID Tracking" check box to monitor the VRID. 7. Click the "Set Values" button. To configure the virtual router, click on the "Configuration" tab. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If you configure more than one subnet on the VLAN and you want a specific IPv4 address to be used as the source address for VRRP packets, select the IPv4 address. Otherwise, the numerically lowest IPv4 address will be used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 376
8. Select the "VRRP Compatible Mode" check box. 9. Select a track ID. 10.Enter the value by which the priority of the VRRPv3 interface will be reduced 11.Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
On this page, you can create, modify or delete the IPv4 addresses to be monitored. A maximum of 10 IPv4 addresses can be monitored by a virtual router. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
When the link of a monitored interface changes from "up" to "down", the priority of the assigned VRRP interface is reduced. You configure the value by which the priority is reduced on the page "Layer 3 > VRRP/VRRPv3 > Configuration". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 379
The table has the following columns: ● Select Select the check box in the row to be deleted. ● Track ID Shows the track ID. ● Interface Shows the interface that is being monitored. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
7. Link the monitoring to a VRRP interface in the "Configuration" tab. 5.6.9 OSPFv2 5.6.9.1 Configuration Introduction On this page, you configure the routing using OSPFv2.. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 381
● Route Map Select a route map that filters which routes are forwarded using RIPv2. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The area identifier 0.0.0.0 is reserved for the backbone area and cannot be deleted. This table contains the following columns: ● Select Select the row you want to delete. ● Area ID Shows the identifier of the area. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
ID. The method is used only with area border routers. This means that an area border router only advertises one route for grouped areas to the outside. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 384
3. Enter the subnet mask of the network that will be grouped. 4. Click the "Create" button. A new entry is generated in the table. 5. Enable the "Advertise" option to advertise the grouped network. 6. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select the ID of the area that is connected to the OSPFv2 interface from the drop-down list. The table has the following columns: ● Select Select the row you want to delete. ● IP address Shows the IPv4 address of the OSPFv2 interface SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 386
3. Click the "Create" button. A new entry is generated in the table. 4. Select the required settings or use the factory defaults. 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– None No authentication – Simple Authentication using an unencrypted password – MD5 Authentication using MD5 Section "Simple Authentication" ● Password Enter a password. ● Confirmation Confirm the entered password. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Due to the protocol, each area border router must have access to the backbone area. If a router is not connected directly to the backbone area, a virtual link to it is created. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 389
● Virt. Link Status Specify the status of the virtual link. The following states are possible: – down: The virtual link is inactive. – point-to-point: The virtual link is active. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 390
3. Click the "Create" button. A new entry is generated in the table. 4. Enter the appropriate values in "Transit Delay", "Retrans. Delay" and "Dead Interval". 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– None No authentication – Simple Authentication using an unencrypted password – MD5 Authentication using MD5 Section "Simple Authentication" ● Password Enter a password. ● Confirmation Confirm the entered password. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
4. Enter the MD5 key and the confirmation of the MD5 key. 5. Click the "Set Values" button. 5.6.10 RIPv2 5.6.10.1 Configuration On this page, you configure the routing using RIPv2. Note RIPv2 is available only on layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select a route map that filters which routes are forwarded using RIPv2. 5.6.10.2 Interfaces Overview On this page, you can configure RIPv2 interfaces. Note RIPv2 is available only on layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 394
RIPv2 updates are sent as broadcasts according to the rules of RIPv1. – RIPv2 Updates for RIPv2 are sent as multicasts. – RIPv1 demand/RIPv2 demand RIP packets are sent only as a response to an explicit query. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the following boxes: ● IGMP Enable or disable IGMP (Internet Group Management Protocol) for the entire device. ● Interface Select the required interface on which you want to configure IGMP. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 396
Steps in configuration 1. Select the "IGMP" check box. 2. Select an interface. 3. Click the "Create" button. 4. Select the required settings in the table. 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Bidirectional Multicast Enable or disable the "bidirectional multicast" functionality globally on the device. 5.6.12.2 Interface Overview On this page, you configure PIM interfaces. Note PIM is available only on layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
When enabled there is no BSR communication via this interface. As a result a PIM network is divided into PIM domains. 5.6.12.3 RP Static Overview On this page you specify which interfaces will become static rendezvous points. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 399
This table contains the following columns: ● Select Select the row you want to delete. ● Group Address Shows the address of the multicast group. ● Group Mask Shows the subnet mask. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
PIM is available only on layer 3. Settings The page contains the following boxes: ● Group Address Enter the address of the multicast group. ● Group Mask Enter the subnet mask that restricts the multicast band. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
IP address and are made known in the network. The RPs are linked together via MSDP sessions. The RPs synchronize their multicast sources via source active messages. Configure MSDP on the rendezvous points. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 402
TCP port via which the device communicates with other MSDP nodes. If you change the listener port, only new MSDP connections are affected that are created after this change. Existing MSDP connections continue to use the previous listener port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the address of the MSDP partner. ● Local Address Shows the IP address of the interface via which the device communicates with the MSDP partner. ● Admin Status Enable or disable the connection. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The page contains the overview of the layer 3 functions for IPv6. On this page, you enable or disable the required layer 3 function. The functions "IPv6 Routing", "VRRPv3" and "OSPFv3" are only available with Layer 3 (IPv6). SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 405
You can configure other settings in "Layer 3 (IPv6) > OSPFv3". Steps in configuration 1. To use the required function, select the corresponding check box. 2. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Enter the number of left-hand bits belonging to the prefix ● IPv6 Address Type Select the address type. – Unicast – Anycast – Link Local IPv6 address is only valid on the link SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 407
5. For "IPv6 Address Type" select the entry "Link Local". 6. Click the "Create" button. In the table an entry with the interface is created and the IPv6 address is displayed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
– Status dependent Obtains the IPv6 address and the configuration file from the DHCPv6 server – Stateless: Obtains only the configuration file from the DHCPv6 server – Prefix Delegation: The DHCPv6 client takes over the distribution of the IPv6 prefix SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Example: Under the prefix name "test", the following IPv6 prefix is stored: 2001:DB8:1234::/48 Prefix = 2002:AF9:5678::1 Prefix length = 64 This results in the following IPv6 address 2001:DB8:1234::1 SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 410
Select the check box in the row to be deleted ● Interface Name Shows the name of the interface ● Prefix Name Shows the name of the prefix. ● Prefix Shows the prefix. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This table contains the following columns: ● Select Select the check box in the row to be deleted. ● Destination Network Shows the network address of the destination. ● Prefix Length Shows the prefix length. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● The comparison is continued until the filters of a route map match the properties of an item of information. ● The information is then processed according to the route map settings: – The routing information is discarded. – The properties of the routing information are changed. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The routing information is discarded. 5.7.5.2 Interface & Value Match On this page, you specify whether or not the routing information for a route map is filtered according to interfaces, metric or tags. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 414
This box is active only if you have selected the "Metric" entry in the "Type" drop-down list. ● Tag Enter a value for the tag. This box is active only if you have selected the entry "Tag in the "Type" drop-down list. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 415
Shows the selected type: – Interface – Metric – Tag – Route Type – metric type ● Value Shows the selected interface or the value of the metric or of the tag. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Next-Hop filtern On this page, you specify whether or not the filtering for a route map will be based on the router to which the routing information is sent next. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If, for example, you have filtered based on a certain metric, you can change the value of the metric here. The routing information is then forwarded with the new value. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 418
Enter the new value for the metric with which the routing information will be forwarded. ● Tag Enter the new value for the tag with which the routing information will be forwarded. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● Select Select the row you want to delete. ● Interface Interface to which the settings relate. ● Current Remote ID Shows which remote ID is currently being used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
5.7.6.2 Server Addresses On this page you enable the DHCPv6 relay agent on the interface. You also specify which DHCPv6 server can be reached via it. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The link local multicast address (ff02::1:2 ) of the DHCPv6 server can only be reached by devices located on the same link. On this page, you specify the interface via which this DHCPv6 server can be reached. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Simultaneous operation of VRRP and VRRPv3 is not possible. ● Select the "VRRPv3" check box to configure VRRPv3. ● You can use VRRPv3 on VLAN interfaces. Router ports are not supported. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 423
Shows the numerically lowest IPv6 address in this VLAN. The entry "::" means that the "Primary" address on this VLAN is used. Otherwise all IPv6 addresses configured on this VLAN in the "Layer 3 (IPv6) > Subnets" menu are valid values. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 424
VRRP group again. Steps in configuration 1. Select the "VRRPv3" check box. 2. Select the required interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
6. Click the "Set Values" button. To configure the virtual router, click on the "Configuration" tab. 5.7.7.2 Configuration Introduction On this page, you configure the virtual router. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 426
To configure a virtual router as the master router, follow the steps below: 1. Select the ID of the virtual router you want to configure from the "Interface / VRID" drop- down list. 2. Select the "Status" check box. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Description of the displayed values The table has the following columns: ● Interface Shows the Interface that functions as the virtual router. ● VRID Shows the ID of this virtual router. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The table has the following columns: ● Select Select the check box in the row to be deleted ● Associated IP Address Shows the IPv6 addresses that the virtual router monitors. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Description of the displayed values The page contains the following boxes: ● Interface From the drop-down list, select the interface to be monitored. ● Track ID Enter a track ID. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
7. Link the monitoring to a VRRP interface in the "Configuration" tab. 5.7.8 OSPFv3 5.7.8.1 Configuration Introduction On this page, you configure the routing using OSPFv3. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 431
Shows the number of different LSAs sent by this local system. ● External LSA Maximum To limit the number of entries of external LSAs in the database, enter the maximum number of external LSAs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
An autonomous system can be divided into smaller areas. On this page, you can view, create, modify or delete the areas of the router. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 433
– No Summary: Summary LSAs are not generated and sent to the area. ● Metric Displays the costs for the OSPFv3 interface. ● Updates Shows the number of recalculations of the routing tables. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
This means that an area border router only advertises one route for grouped areas to the outside. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
5. Enable the "Advertise" option to advertise the grouped network. 6. Click the "Set Values" button. 5.7.8.4 Interfaces Overview On this page, you can configure OSPFv3 interfaces. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 436
– Enabled: No OSPFv3 information (e.g. Hello frames and LSDB updates) is sent via this interface and learned. – Disabled: OSPFv3 information is sent and learned via this interface. ● Metric Enter the costs for the OSPFv3 interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Due to the protocol, each area border router must have access to the backbone area. If a router is not connected directly to the backbone area, a virtual link to it is created. Note This function is available only with layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 438
– point-to-point: The virtual link is active. ● Trans. Delay Enter the required delay when sending a connection update. Range of values: 1 s to 3600 s Default: 1 s SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
4. Enter suitable values in "Trans. Delay", "Retrans. Interval" and "Dead Interval". 5. Click the "Set Values" button. 5.7.9 RIPng 5.7.9.1 RIPng Configuration On this page, you configure routing with RIPng. Note RIPng is available only on layer 3. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select a route map that filters which routes are forwarded using RIPng. 5.7.9.2 RIPng interfaces Overview On this page, you specify the interfaces that support RIPng. Figure 5-21 RIPv2 Interfaces SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"Vendor Specific". To ensure compatibility with firmware versions ≤ 5.0, the default setting was selected so that following a firmware update the earlier authentication mode "conventional" continues to be used. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 442
For the RADIUS authorization mode "Vendor Specific" the following needs to be set on the RADIUS server: ● Manufacturer code: 4196 ● Attribute number: 1 ● Attribute format: Character string (group name) Procedure SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 443
Case C: The RADIUS server reports a failed authentication to the device: – The user is denied access. Assignment of a VLAN via RADIUS or guest VLAN Authentication with a change to the VLAN configuration SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
"External User Accounts". If you want to make change explicitly for the internal or external user table, use the CLI commands. Note The values displayed depend on the rights of the logged-in user. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 445
Configuring with Web Based Management 5.8 The "Security" menu SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 446
● Password Confirmation Enter the password again to confirm it. ● Role Select a role. You can choose between system-defined and self-defined roles, refer to the page "Security > Users > Roles.". SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
2. Click the "Delete" button. The entries are deleted and the page is updated. 5.8.2.2 Roles Roles On this page, you create roles that are valid locally on the device. Note The values displayed depend on the rights of the logged-in user. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 448
● Select Select the check box in the row to be deleted. Note Predefined roles and assigned roles cannot be deleted or modified. ● Role Shows the name of the role. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
In this example the group "Administrators" is linked to the "admin"role: The group is defined on a RADIUS server. The role is defined locally on the device. When a RADIUS server SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 450
Enter a description for the link of the group.to a role. The description text can be up to 100 characters long. Procedure Linking a group to a role. 1. Enter the name of a group. 2. Click the "Create" button. 3. Select a role. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Shows the user that is currently logged in. ● Current User Password Enter the password for the currently logged in user. ● User Account Select the user whose password you want to change. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 452
3. Enter the new password for the selected user in the "New Password" input box. 4. Repeat the new password in the "Password Confirmation" input box. 5. Click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
The designation used "AAA"" stands for "Authentication, Authorization, Accounting". This feature is used to identify and allow network nodes and to make the corresponding services available to them. On this page, you configure the login. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If the primary server cannot be reached, secondary servers are queried in the order in which they are entered. If no server responds, there is no authentication. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 455
1 to 65535. ● Shared Secret Enter your access ID here. The range of values is 1...128 characters ● Shared Secret Conf. Enter your access ID again as confirmation. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 456
– Reachable, key accepted The IP address is reachable, the RADIUS server accepts the specified shared secret. The test result is not automatically updated. To delete the test result click the "Refresh" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 457
– Primary Server 2. Click the "Set Values" button. 3. If necessary, test the reachability of the RADIUS server. Repeat this procedure for every server whose entry you want to modify SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
By enabling the relevant options , you specify for each port whether or not network access protection according to IEEE 802.1X is enabled on this port. Figure 5-22 802.1x Authenticator - first part of the table SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 459
If "No Change" is selected, the entry in table 2 remains unchanged. ● RADIUS VLAN Assignment Allowed Select the required setting. If "No Change" is selected, the entry in table 2 remains unchanged. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 460
802.1X" procedure, the 5 seconds may not be not adequate. To be able to run authentication using "802.1X", disable the MAC authentication on this port. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 461
The port can only be assigned to the VLAN, if the VLAN has been created on the device. Otherwise Authentication (Page 441) is rejected. This function is also known as "Authentication failed VLAN". ● Guest VLAN ID Enter the VLAN ID of the guest VLANs. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 462
1. Select the required options in table 1. 2. Click the "Copy to table" button. The relevant settings are adopted for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Ingress Interfaces Shows a list of all ingress interfaces to which this rule applies. ● Egress Interfaces Shows a list of all egress interfaces to which this rule applies. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 464
5. Click the "Set Values" button. Deleting an entry You cannot delete active entries. 1. Enable "Select" in the row to be deleted. 2. Click the "Delete" button. The entry is deleted. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
● Rule Order Shows the order of the ACL rules. ● Rule Number Shows the number of the ACL rule. ● Source MAC Shows the unicast MAC address of the source. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 466
1. Select the interface from the "Interface" drop-down list. 2. Select the ACL rule in the "Remove Rule" drop-down list. 3. Click the "Remove" button. The corresponding entry is removed in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
To remove the ACL rule from the interface, click the "Remove" button. The table has the following columns: ● Rule Order Shows the order of the ACL rules. ● Rule Number Shows the number of the ACL rule. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 468
1. Select the interface from the "Interface" drop-down list. 2. Select the ACL rule in the "Remove Rule" drop-down list. 3. Click the "Remove" button. The corresponding entry is removed in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule. – Forward If the frame complies with the ACL rule, the frame is forwarded. – Discard If the frame complies with the ACL rule, the frame is not forwarded. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
1. Enable "Select" in the row to be deleted. 2. Click the "Delete" button. The entry is deleted. 5.8.6.2 Protocol Configuration On this page, you specify the rules for protocols. Settings Figure 5-24 IP ACL Protocol Configuration SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 471
This box can only be edited if you have set "ICMP" for the protocol. ● DSCP Enter a value for classifying the priority. This box cannot be edited if you have set "ICMP" for the protocol. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If you use a VLAN interface, the ACL rule applies to all ports that belong to the VLAN. ● Add Rule In the drop-down list select the ACL rule to be assigned to the interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 473
Shows the lowest possible port number of the destination port. ● Dest. Port Max. Shows the highest possible port number of the destination port. ● Message Type Shows a message type to decide the format of the message. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 474
1. Select the interface from the "Interface" drop-down list. 2. Select the ACL rule in the "Remove Rule" drop-down list. 3. Click the "Remove" button. The corresponding entry is deleted. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Egress Rules Introduction On this page, you specify the ACL rules according to which outgoing frames are handled by interfaces. You specify the ACL rules in the "Rules Configuration" tab. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 476
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule. – Forward If the frame complies with the ACL rule, the frame is forwarded. – Discard If the frame complies with the ACL rule, the frame is not forwarded. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
You can select the protocols and the ports of the station with which it is allowed to access the device. You define the VLAN in which the station may be located. This ensures that only certain stations within a VLAN have access to the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 478
The table has the following columns: ● Select Select the row you want to delete. ● Rule Order Shows the order of the ACL rules. ● IP Address Shows the IP address. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 479
1. In the "IP Address" input box, enter the IP address of the device and in the "Subnet Mask / Prefix Length" input box the corresponding subnet mask or prefix length. 2. Click the "Create" button to create a new row in the table. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 480
1. Select the check box in the row to be deleted. 2. Repeat this procedure for every entry you want to delete. 3. Click the "Remove" button. The entries are deleted and the page is updated. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If there is a power failure during the firmware update, it is possible that the IE switch is no longer accessible using Web Based Management or the Command Line Interface. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
If you now change a parameter directly on the device (WBM/CLI/SNMP) these changes are lost when the device restarts. Solution 1. Open the relevant STEP 7 project in STEP 7 Basic / Professional 2. Open the project view. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 483
The configuration is saved on the device. The message is no longer visible in the display area. A configuration change directly on the device is no longer lost due to a restart of the device. SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 484
Troubleshooting/FAQ 6.3 Message: SINEMA configuration not yet accepted SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
IPv6 Stateless Address Autoconfiguration 5095 Deprecation of Type 0 Routing Headers in IPv6 6603 Prefix Exclude Option for DHCPv6-based Prefix Delegation 6724 Default Address Selection for Internet Protocol version 6 (IPv6) SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...
Page 486
Appendix A A.1 Supported RFCs SCALANCE XM-400/XR-500 Web Based Management (WBM) Configuration Manual, 05/2017, C79000-G8976-C248-12...