Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
Page 4
2.12.4 Eth-Trunk Preferentially Forwarding Local Traffic ....................34 3 Product Capability ........................35 3.1 Stack Cables ................................35 3.2 Stack Parameters of S Series Switches ........................37 3.3 Switches That Do Not Support Stacking ........................42 4 Application Scenarios ........................ 43 4.1 Configuring a Stack with a Ring Topology .........................
Technology White Paper 1 Feature Introduction Feature Introduction 1.1 iStack Overview Currently, two models of Huawei switches are available on the network: box switches and chassis switches. Box switches have low costs but lack uninterrupted service protection, and cannot apply to the scenarios that require high availability, such as the aggregation layer, core layer, and data center.
MPU fails, the standby MPU becomes the new master MPU and starts to process services. A Huawei box switch has only one control plane and cannot implement redundancy. If a box switch fails, the connected network is interrupted. iStack technology can implement 1:1 redundancy on box switches.
Connector X1/X2 PCIE Color Black Length Bend radius 75 mm 3.2 Stack Parameters of S Series Switches Table 3-7 Stack parameters of S2750-EI series switches Stack Parameter S2750-EI Stack connection mode Service port connection Stack port Two SFP ports (not combo ports) ...
NOTE Saving the results of each troubleshooting step is recommended. If your troubleshooting fails to correct the fault, you will have a record of your actions to provide Huawei technical support personnel. CAUTION Before replacing a switch, inserting a stack card or stack cable, or replacing a stack card, power off the switch.
Page 64
ID 0, run the display elabel slot 0 2 command. If all fields under [Board Properties] are empty, the stack card does not function properly. Replace the stack card. <HUAWEI> display elabel slot 0 2 /$[System Integration Version] /$SystemIntegrationVersion=3.0 [Slot_0] /$[Board Integration Version] /$BoardIntegrationVersion=3.0...
Page 65
Item= Description= Manufactured= VendorName= IssueNumber= CLEICode= BOM= If fields under [Board Properties] are not empty, go to step 6. <HUAWEI> display elabel slot 0 2 /$[System Integration Version] /$SystemIntegrationVersion=3.0 [Slot_0] /$[Board Integration Version] /$BoardIntegrationVersion=3.0 [Main_Board] /$[ArchivesInfo Version] /$ArchivesInfoVersion=3.0 [Board Properties]...
If the fault persists, go to step 8. Step 8 Collect the following information and contact Huawei technical support personnel. Results of the preceding troubleshooting procedure ...