Once you have released the hopper assembly, toner
can spill over the toner bottle supply mouth of the
hopper assembly cover. Be sure to wipe off any such
toner.
F-7-434
3) Remove the 3 screws [1].
[1]
F-7-435
4) Close the black toner supply cover [1]; then, fully
open the hopper assembly [2].
[2]
[1]
F-7-436
7.11.13.4 Sliding Out the
Process Unit
1) Disconnect the 5 connectors [1] found at the upper
right.
[1]
[1]
F-7-437
2) Disconnect the 5 connectors [1] found at the upper
left.
[1]
[1]
F-7-438
3) After freeing the high voltage connector cable [1]
from the 2 wire saddles [2], fix the cable in place using
the cable hook [3].
[2]
[1]
F-7-439
Chapter 7
0004-1093
[1]
[3]
7-145