15.5.1.5 CST
15.5.1.5.1 Overview
Cassette/Manual Feed Tray Related Auto Adjustment
15.5.1.5.2 <MF A4R, MF A6R, MF A4>
Method of operation
15.5.1.6 CLEANING
15.5.1.6.1 Overview
Cleaning Operation
15.5.1.6.2 <TBLT CLN>
Operation
T-15-184
Use it to enter the paper width basic value for the manual feeder.
A4 width: 210 mm; A6R width: 105 mm; A4 width: 297 mm
To make fine adjustments, make the following selections:
COPIER>ADJUST>CST ADJ>MF A4, RMF A6R, MF A4.
1) Place A4 paper in the manual feeder, and adjust the size guide to A4R width.
2) Using this service mode item, select 'MF A4R' to highlight, and press the
OK key (so that the value will be stored after auto adjustment).
3) Likewise, perform steps 1) and 2) to register the basic value for A6R and A4.
T-15-185
Use it to clean the intermediate transfer belt.
The foreign matter, if any, (e.g., oils from fingers,
paper lint) sticking to the intermediate transfer belt is
removed to correct image faults
Select the item to highlight, and press the OK key to
execute. The operation will stop automatically
Chapter 15
0001-0251
0001-0252
0001-0254
0005-6481
15-115