Multimode and single mode ethernet fiber switch (46 pages)
Summary of Contents for Siemens SCALANCE XB-200
Page 1
___________________ SCALANCE XB-200 Web Based Introduction Management ___________________ Description ___________________ SIMATIC NET Assignment of an IP address ___________________ Technical basics Industrial Ethernet switches SCALANCE XB-200 Web Based ___________________ Configuring with Web Based Management Management ___________________ Troubleshooting/FAQ Configuration Manual 04/2015 C79000-G8976-C360-02...
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
There are two variants of each device with different article numbers. The two variants differ only in their factory settings. All other properties are identical. This Configuration Manual applies to the following software version: ● SCALANCE XB-200 firmware as of version 1.1 Factory settings EtherNet/IP variants ●...
Page 8
● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
Page 9
Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
Page 10
Introduction SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Description Product characteristics The SCALANCE XB-200 IE switches have the following properties: ● The Ethernet interfaces support the following modes: – 10 Mbps and 100 Mbps both in full and half duplex – Autocrossing – Autopolarity ● EtherNet/IP EtherNet/IP (Ethernet/Industrial Protocol) is an open industry standard for industrial real- time Ethernet based on TCP/IP and UDP/IP.
A PG/PC with a network connection must be available in order to configure the IE switches. An IP address must be assigned to the IE switch and it must be available in the network, see also "Initial assignment of an IP address (Page 15)". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
To find out whether two IP addresses belong to the same subnet, the two IP addresses and the subnet mask are ANDed bit by bit. If both logic operations have the save result, both IP addresses belong to the same subnet, for example, 141.120.246.210 and 141.120.252.108. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 14
IP address. Note In the bit representation of the subnet mask, the "ones" must be set left-justified; in other words, there must be no "zeros" between the "ones". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
– To be able to assign an IP address to the IE switch with the PST, it must be possible to reach the IE switch via Ethernet. – You will find the PST on the Internet pages of Siemens Industry Online Support under the entry ID 19440762 (http://support.automation.siemens.com/WW/view/en/19440762).
The device therefore remains accessible under the last assigned IP address even without a DHCP server. This is not the standard behavior of office devices but is necessary for problem-free operation of the plant. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Virtual LANs (including VLAN 1) Mirroring sessions Unicast filtering Multicast groups Static MAC addresses in the forward database (FDB) Security IP addresses from RADIUS servers Management ACLs (access rules for management) SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
EDS (Electronic Data Sheet). Electronic Data Sheet Electronic Data Sheets (EDS) are electronic datasheets for describing devices. The EDS required for EtherNet/IP operation can be found in "System > Load&Save (Page 77)". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
PROFINET IO Within the framework of PROFINET, PROFINET IO is a communications concept for implementing modular, distributed applications. PROFINET IO is implemented by the PROFINET standard for programmable controllers (IEC 61158-x-10). SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
New configuration data is not used immediately by a bridge but only after the period specified in the "Forward Delay" parameter. This ensures that operation is only started with the new topology after all the bridges have the required information. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The number of bridge hops a package is allowed to make before it automatically becomes invalid. In principle, therefore with rapid spanning tree, alternatives for many parameters are preconfigured and certain properties of the network structure taken into account to reduce the reconfiguration time. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"Automatic Redundancy Detection" mode must be activated. This can be achieved in Web Based Management, Command Line Interface or using SNMP. ● In the basic status, the "HRP Client" or "Automatic Redundancy Detection" mode is set as default. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
These include, for example, some of the Industrial Ethernet SCALANCE X switches, some of the communications processors (CPs) for SIMATIC S7 and PG/PC or non- Siemens devices that support this function. ● All devices must be interconnected via their ring ports.
Page 24
● All other devices in the ring are redundancy clients. Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via a PC with a CP 1616. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
– For all other devices in the ring select "MRP Client" or "Automatic Redundancy Detection". ● You want to use MRP in a ring topology that also includes non-Siemens devices: – For exactly one device in the ring select the role "MRP Auto Manager".
If you want to use the "prioritized startup" function, then disable MRP in the configuration. In the STEP 7 configuration, set the role of the relevant device to "Not a node in the ring". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 27
Role The choice of role depends on the following use cases. ● You want to use MRP in a topology with one ring only with Siemens devices and without monitoring diagnostic interrupts: Assign all devices to the "mrpdomain-1" domain and the role "Manager (Auto)".
Page 28
• SCALANCE X-200, SCALANCE XB-200 (PROFINET variants), SCALANCE X-300 and SCALANCE X-400: "Automatic Redundancy Detection" If you are operating a non-Siemens device as the redundancy manager in the ring, this may cause loss of the data traffic. With brand new SCALANCE XB-200 (EtherNet/IP variants), SCALANCE XM-400 and SCALANCE XR-500 IE switches and those set to the factory settings, MRP is disabled and spanning tree enabled.
Ethernet connection to the substitute (slave) Ethernet connection. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 30
If there are no problems, only the link from the master to the other network segment is active. If this link fails (for example due to a link-down or a device failure), the slave activates its link as long as the problem persists. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The end nodes on the networks must be checked to find out whether they can process this length / this frame type. If this is not the case, only frames of the standard length may be sent to these nodes. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 32
Guaranteed service, interactive voice transmission Reserved The prioritization of the data packets is possible only if there is a queue in the components in which they can buffer data packets with lower priority. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 33
The frame contains only priority information (priority tagged frames) and no valid VLAN identifier. 1 - 4094 Valid VLAN identifier, the frame is assigned to a VLAN and can also include priori- ty information. 4095 Reserved SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
SNMP data packets are not encrypted and can easily be read by others. The central station is also known as the management station. An SNMP agent is installed on the devices to be monitored with which the management station exchanges data. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 35
Compared with the previous versions SNMPv1 and SNMPv2. SNMPv3 introduces an extensive security concept. SNMPv3 supports: ● Fully encrypted user authentication ● Encryption of the entire data traffic ● Access control of the MIB objects at the user/group level SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 36
Technical basics 4.7 SNMP SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"Settings" button. Under "Check for newer versions of stored pages:", select "Automatically". ● If a firewall is used, the relevant ports must be opened. – For access using HTTP: TCP port 80 – For access using HTTPS: TCP port 443 SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 38
The display on the WBM pages and how you work with them on mobile devices may differ compared with the same pages on desktop devices. Some pages also have an optimized display for mobile devices. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
1. From the drop-down list at the top right, select the language version of the WBM pages. 2. Click the "Go" button to change to the selected language. Note Available languages in this version, only English is available. Other languages will follow in a later version. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 40
– "user": standard password "user" 5. Click the "Login" button or confirm your entry with "Enter". When you log in for the first time or following a "Restore Factory Defaults and Restart", SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The following areas are generally available on every WBM page: ● Selection area (1): Top area ● Display area (2): Top area ● Navigation area (3): Left-hand area ● Content area (4): Middle area SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 42
Configuring with Web Based Management 5.3 The "Information" menu SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 43
When you click this button, the help page of the currently selected menu item is opened in a new browser window. The help page contains a description of the content area. Under certain circumstances, options are described that are not available on the device. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 44
PROFINET IO controller. In this status, the parameters set by the PROFINET IO controller cannot be configured on the device. – Offline There is no connection to a PROFINET IO controller. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 45
● Page up with "Prev" The number of data records that can be displayed on a page is limited. Click the "Prev" button to page up through the data records. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the version of the boot software stored on the device. – Firmware_Running Shows the firmware version currently being used on the device. ● Description Shows the short description of the software. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the manufacturer ID. ● Order ID Shows the order number. ● Serial Number Shows the serial number. ● Hardware Revision Shows the hardware version. ● Software Revision Shows the software version. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The table has the following columns: ● Interface Shows the interface via which the row entry was learnt. ● MAC Address Shows the MAC address of the target or source device. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"System > Events" menu. This, for example, allows you to record when an authentication attempt failed or when the connection status of a port has changed. The content of the events log table is retained even when the device is turned off. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 50
1200. When this number is reached, the oldest entries are discarded. The table remains permanently in memory. "Show all" button Click this button to display all the entries on the WBM page. Note that displaying all messages can take some time. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the time the device has been running since the last restart when the described fault occurred. ● Fault Description Display of the fault status for the device. ● Clear Fault State If the "Clear Fault State" button is enabled, you can delete the fault. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Click the "Reset Counter" to reset all counters. The counters are reset by a restart. 5.3.7 Redundancy 5.3.7.1 Spanning tree Introduction The page shows the current information about the spanning tree and the settings of the root bridge. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 53
● Root Cost Shows the path costs from the device to the root bridge. ● Bridge Status Shows the status of the bridge, e.g. whether or not the device is the root bridge. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 54
0 and 240 can be entered for the priority in steps of 16. If you enter a value that cannot be divided by 16, the value is automatically adapted. The default is 128. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 55
Shows the type of point-to-point link. The following values are possible: – P.t.P. With half duplex, a point-to-point link is assumed. – S hared Media With a full duplex connection, a point-to-point link is not assumed. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
If you set the role "Manager (Auto)" or "Manager" for the device in STEP 7, in both cases, "MRP Manager" is displayed on this WBM page. In the display in the CLI, a distinction is made between the two roles. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 57
If the redundancy function is disabled or the device is an HRP/MRP client , the text "Redundancy Manager Disabled" appears. Description of the button "Reset Counter" button Click "Reset Counter" to reset all counters. The counters are reset by a restart. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The Standby tab shows the status of the standby function: Description of the displayed values The following boxes are displayed: ● Standby Ports Shows the standby port. ● Standby Name Standby Connection Name SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 59
If the standby function is disabled, the text "Standby Disabled" appears in this box. Description of the button "Reset Counter" button Click "Reset Counter" to reset all counters. The counters are reset by a restart. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the number of received unicast frames. ● In Non-Unicast Shows the number of received frames that are not of the type unicast. ● Out Unicast Shows the number of sent unicast frames. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The displayed values are transferred by RMON. On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be displayed. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 62
For technical reasons, data packets can be indicated on blocked ports. Description of the button "Reset Counter" button Click "Reset Counter" to reset all counters. The counters are reset by a restart. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"Unicast", "Multicast" and "Broadcast". Description of the button "Reset Counter" button Click the "Reset Counter" to reset all counters. The counters are reset by a restart. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Packets with a length less than 64 bytes. – Oversize Packets discarded because they were too long. – F ragments Packets with a length less than 64 bytes and a bad CRC checksum. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● VLAN ID Shows the VLAN ID assigned to this MAC address. ● MAC Address Shows the MAC address of the node that the device has learned or the user has configured. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
This table shows the multicast frames currently entered in the multicast filter table and their destination ports. The entries can be dynamic (the device has learned them) or static (the user has set them). Figure 5-2 Multicast SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
LLDP agent has received from connected devices. You set the interfaces via which the LLDP agent receives or sends information in the following section: "Layer 2 > LLDP". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 68
– Bridge – Telephone – DOCSIS Cable Device – WLAN Access Point – Repeater – Station – Other ● Port ID Port of the device with which the IE switch is connected. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
When this function is enabled, you can only access the device using HTTPS. ● SMTP Client Enable or disable the SMTP client. You can configure other settings in "System > SMTP Client". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 70
Enable or disable the DHCP client. You can configure other settings in "System > DHCP Client". ● SNMPv1 Traps Enable or disable the sending of traps (alarm frames). You can configure other settings in "System > SNMP > Traps". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 71
Steps in configuration 1. To use the required function, select the corresponding check box. 2. Select the options you require from the drop-down lists. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
A maximum of 255 characters are possible. The system name is also displayed in the CLI input prompt. The number of characters in the CLI input prompt is limited. The system name is truncated after 16 characters. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The geographic coordinates can also be obtained using a GPS receiver. The geographic coordinates of these devices are normally displayed directly and only need to be entered in the input boxes of this page. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 74
1. Enter the latitude in the "Latitude" input box. 2. Enter the longitude in the "Longitude" input box. 3. Enter the height in the "Height" input box. 4. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Enter the subnet mask of the device. ● Default Gateway Enter the IP address of the default gateway to be able to communicate with devices in another subnet, for example diagnostics stations, e-mail server. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Values" button on the relevant WBM page. If the device is in "Trial Mode", configuration modifications must be saved manually before a restart. In "Autosave mode", the last changes are saved automatically before a restart. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
ConfigPack Detailed configuration information. for example, start configuration, users, certificates Copyright OSS licenses Debug This file contains information for Siemens Support. Electronic Data Sheet (EDS) Electronic data sheets for describing devices in the EtherNet/IP mode Firmware Firmware GSDML Information on the device properties...
This WBM page is available both for connections using HTTP and for connections using HTTPS. Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with predecessor firmware versions During the installation of a previous version, the configuration data can be lost.
Page 79
With this button, you can delete files from the device. The button can only be enabled if this function is supported by the file type and the file exists on the device. Note Following a firmware update, delete the cache of your Internet browser. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 80
3. If individual settings are necessary for specific devices, these must be made online on the relevant device. Note Configuration data has a checksum. If you edit the files, you can no longer upload them to the IE switch. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
TFTP server to the devices. This means, for example, that you can also load new firmware from a file located on a TFTP server. Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with predecessor firmware versions During the installation of a previous version, the configuration data can be lost.
Page 82
69 to your own requirements. The table has the following columns: ● Type Shows the file type. ● Description Shows the short description of the file type. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 83
2. Load this configuration file on all other devices you want to configure in this way. 3. If individual settings are necessary for specific devices, these must be made online on the relevant device. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The "Enabled" check box is selected but the password does not match the certificate or no certificate has been loaded yet. – '-' The password cannot be evaluated or is not yet being used. The "Enabled" check box is not selected. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
On this page, you specify how a device reacts to system events. By enabling the appropriate options, you specify how the device reacts to events. To enable or disable the options, click the relevant check boxes of the columns. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 86
(standby port). The data traffic was redirected from one Ethernet connection (standby port of the master) to another Ethernet connection (standby port of the slave). – Loop detection A loop was detected in the network segment. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 87
1. Select the check box in the row of the required event. Select the event in the column under the following actions: – E-mail – Trap – Log table – Syslog – Fault 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Follow the steps below to configure the required level: 1. Select the required values from the drop-down lists of the second table column after the client types. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● Sender Email Address Enter the e-mail address to be specified in the e-mail. This setting applies to all configured SMTP servers. ● Send Test Mail Send a test e-mail to check your configuration. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 90
Depending on the properties and configuration of the SMTP server, it may be necessary to adapt the "Sender Email Address” box for the e-mails. Check with the administrator of the SMTP server. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The table has the following columns: ● Interface Interface to which the setting relates. ● DHCP Enable or disable the DHCP client for the relevant interface. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"Client Configuration Request (Opt.66, 67)" is no longer set in this configuration file. 5.4.9 SNMP 5.4.9.1 General Configuration of SNMP On this page, you make the basic settings for SNMP. Enable the check boxes according to the function you want to use. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 93
3. Enter the required character string in the "SNMPv1/v2c Read Community String" input box. 4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String" input box. 5. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● IP Address If necessary, change the IP addresses of the stations. ● Trap Enable or disable the sending of traps. Stations that are entered but not selected do not receive SNMP traps. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
SNMP version 3 allows permissions to be assigned, authentication, and encryption at protocol level. The security levels and read/write permissions are assigned according to groups. The settings automatically apply to every member of a group. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 96
SNMPv3 user, no automatic saving is triggered and the configured group disappears again after restarting the device. – Yes The group is assigned to an SNMPV3 user. – No The group is not assigned to an SNMPV3 user. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 97
Deleting a group 1. Enable "Select" in the row to be deleted. Repeat this for all groups you want to delete. 2. Click the "Delete" button. The entries are deleted. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Select the group to which the user will be assigned. ● Authentication Protocol Specify the authentication protocol. Can only be enabled, if this group supports the function. The following settings are available: – none – MD5 – SHA SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 99
5. If encryption was specified for the group, select the algorithm from the "Privacy Protocol" drop-down list. In the relevant input boxes, enter the encryption password and the confirmation. 6. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
5.4.10.1 Manual setting Manual setting of the system time On this page, you set the date and time of the system yourself. For this setting to be used, enable "Time Manually". SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 101
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY HH:MM:SS". 4. Click the "Set Values" button. The date and time are adopted and "Manual" is entered in the "Last Synchronization Mechanism" box. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the current date and current normal time received by the IE switch. If you specify a time zone, the time information is adapted accordingly. ● Last Synchronization Time This box is read-only and shows when the last time-of-day synchronization took place. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 103
– 1025 to 36564 ● Poll Interval(s) Here, enter the interval between two-time queries. In this box, you enter the query interval in seconds. Possible values are 16 to 16284 seconds. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 104
6. In the "Poll Interval(s)" input box, enter the time in seconds after which a new time query is sent to the time server. 7. Click the "Set Values" button to transfer your changes to the device. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the current date and current normal time received by the IE switch. If you specify a time zone, the time information is adapted accordingly. ● Last Synchronization Time This box is read-only and shows when the last time-of-day synchronization took place. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 106
1. Click the "NTP Client" check box to enable the automatic time setting using NTP. 2. Enter the necessary values in the following boxes: – Time zone – NTP server IP address – NTP server port – Query interval 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The system time was not set. – Manual Manual time setting – SNTP Automatic time-of-day synchronization with SNTP – NTP Automatic time-of-day synchronization with NTP – SIMATIC Automatic time-of-day synchronization using the SIMATIC time frame SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
2. Enter a value of 60-600 seconds in the "CLI (TELNET, SSH, Serial) [s]" input box. If you enter the value 0, the automatic logout is disabled. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
This may cause unwanted disruption in network operation since the device needs to be reconfigured if this occurs. Steps in configuration 1. To use the required functionality, select the corresponding check box. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● Select Select the row you want to delete. ● Server Address Shows the IP address of the Syslog server. ● Server Port Enter the port of the Syslog server being used. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 111
2. Create a new entry. Deleting an entry 1. Select the check box in the row to be deleted. 2. Click the "Delete" button. All selected entries are deleted and the display is refreshed. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Shows the type of the port: Switch Port VLAN Hybrid. The port sends tagged and untagged frames. It is not automatically a member of a VLAN. ● Status Shows whether the port is on or off. Data traffic is possible only over an enabled port. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 113
Shows whether flow control is enabled or disabled for the port. ● Flow Ctrl. Shows whether flow control is working on this port. ● MAC Address Shows the MAC address of the port. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The port is disabled and the connection to the partner device is terminated. Note Reduced current consumption For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 115
● Flow Ctrl. Type Enable or disable flow control for the port. ● Flow Ctrl. Shows whether flow control is working on this port. ● MTU Enter the maximum packet size. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 116
Port overload occurs when the device receives more frames than it can send, for example as the result of different transmission speeds. Steps in configuration 1. Change the settings according to your configuration. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Procedure 1. Click the check box in front of the line name you want to monitor to enable or disable the monitoring function. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
– Down – No Change: The setting in table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 119
1. Select the required setting from the drop-down list of the "Setting"column. 2. Click the "Copy to Table" button. The setting is adopted for all ports of table 2. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
On this page, you configure whether or not an error message is triggered if there is a status change on a network connection. Setting ● Redundancy Lost (HRP only) Enable or disable connection monitoring. If the redundancy of the connection is lost, an error is signaled. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
PROFINET IO controller cannot be configured. ● PNIO Name of Station This box displays the PROFINET IO device name according to the configuration in HW Config of STEP 7. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Set whether EtherNet/IP will be enabled ("On") or disabled ("Off") after the next device restart. Note PNIO AR Status If a PROFINET connection is established; in other words the PNIO AR status is "Online", you cannot enable EtherNet/IP. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Click this button to start the ping function. ● Ping Output This box shows the output of the ping function. ● "Clear" button Click this button to empty the "Ping Output" box. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Automatic re-establishment of the connection can fail and then needs to be done manually. Description The page contains the following boxes: ● Port Select the required port from the drop-down list. ● Run Test Activates error diagnostics. The result is shown in the table. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 125
Displays the status of the cable. ● Distance Displays the distance to the cable end, cable break, or short-circuit. The value for the distance has a tolerance of +/- 1 m. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
If you select this option, you specify the required redundancy mode in the "Redundancy Mode" drop-down list. – Spanning Tree If you select this option, you specify the required compatibility mode in the "Redundancy Mode" drop-down list. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 127
20 and 30 seconds. – RSTP Enables Rapid Spanning Tree Protocol (RSTP). If a spanning tree frame is detected at a port, this port reverts from RSTP to spanning tree. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 128
Enable or disable port mirroring. You can configure other settings in "Layer 2 > Mirroring". ● Loop Detection Enable or disable the loop detection function. This allows loops in the network to be detected. You will find other settings in "Layer 2 > Loop Detection" SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The higher the queue number, the higher the send priority. The DSCP codes are assigned to the queues as follows: ● DSCP codes 0 - 15 → Queue 1 ● DSCP codes 16 - 31 → Queue 2 SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● Limit Ingress Unicast (DLF) / Limit Ingress Broadcast / Limit Ingress Multicast Select the required setting in the drop-down list. – enabled: Enables the function. – disabled: Disables the function – No Change: The setting in table 2 remains unchanged SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 132
2. To use the limitation for the incoming frames, select the check box in the row. For outgoing frames, the value in the "Egress Rate" column is used. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Up to 257 VLANs can be defined. ● Name Enter a name for the VLAN. The name only provides information and has no effect on the configuration. The length is a maximum of 32 characters. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 134
4. Specify the use of the port in the VLAN. If, for example you select M, the port is a member of the VLAN. The frame sent in this VLAN is forwarded with the corresponding VLAN tag. 5. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
This priority specifies how the frame is further processed compared with other frames. There are a total of eight priorities with values 0 to 7, where 7 represents the highest priority (IEEE 802.1p Port Priority). SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Mirroring a port means that the data traffic at a port (mirrored port) of the IE switch is copied to another port (monitor port). You can mirror one or more ports to a monitor port. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Disable port mirroring if you want to connect a normal end device to the monitor port. Settings The page contains the following boxes: ● Mirroring Click this check box to enable or disable mirroring SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 138
1. Click the "Create" button to create an entry in the table. The session ID is assigned automatically. 2. Select the settings. 3. Click the "Set Values" button to save and activate the selected settings. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Enable or disable listening in on outgoing packets at the required port. Note Mirroring with ring ports If you enable the mirroring function for a ring port, the ring port sends test frames even in the "link down" status. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
630 seconds Steps in configuration 1. Select the "Dynamic MAC Aging" check box. 2. Enter the time in seconds in the "Aging Time [s]" input box. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
"MRP Manager". The device with the lowest MAC address will always become "MRP Manager". The other devices automatically set themselves to "MRP Client" mode. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 142
If you have restored the factory defaults, ring redundancy is disabled and the default ports are used as the ring ports. This can lead to circulating frames and failure of the data traffic if other settings were used in a previous configuration. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
This identifies the two devices as standby partners that belong together. Note To be able to use the function, HRP must be activated. The standby manager always requires an activated HRP client. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 144
Here, enter the name for the standby connection. This must be identical to the name entered on the standby partner. You can select any name to suit your purposes, however, you can only use the name for one pair of devices in the entire network. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 145
As a result, a functioning Ethernet connection to the connected network segment (HRP ring or HRP linear bus) is restored. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
– STP – RSTP Steps in configuration 1. Select the "Spanning Tree" check box. 2. From the "Protocol Compatibility" drop-down list, select the type of compatibility. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
MAC address of the root bridge. ● Root Port Shows the port over which the switch communicates with the root bridge. ● Root Cost The path costs from this device to the root bridge. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 148
Click this button to reset the counters on this page. Steps in configuration 1. Enter the data required for the configuration in the input boxes. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Port is not integrated in the spanning tree. – No Change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 150
Typical values for path costs with rapid spanning tree: – 10,000 Mbps = 2,000 – 1000 Mbps = 20,000 – 100 Mbps = 200,000 – 10 Mbps = 2,000,000 The values can, however, also be set individually. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 151
With an end device, a switch can change over the port faster without taking into account spanning tree frames. If a spanning tree frame is received despite this setting, the port automatically changes to the "Disabled" setting for switches. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 152
1. In the input cells of the table row, enter the values of the port you are configuring. 2. From the drop-down lists of the cells of the table row, select the values of the port you are configuring. 3. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
● Enhanced Passive Listening Compatibility Enable or disable this function for the entire device. Steps in configuration 1. Enable or disable "Enhanced Passive Listening Compatibility" 2. Click the "Set Values" button SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Note that loop detection is only possible at ports that were not configured as ring ports or standby ports. Description ● Loop Detection Enable or disable the loop detection. ● VLAN Loop Detection Enable or disable the VLAN loop detection. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 155
● Status This box shows whether loop detection is enabled or disabled for this port. ● Source port Shows the output port of the loop detection frame that triggered the last reaction. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
All the ports of the device are displayed on this page. After each displayed port, there is a drop-down list for function selection. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 157
Steps in configuration 1. From the options in the drop-down list in the row, select which ports should support sending DCP frames. 2. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Filtering Address filtering This table shows the source addresses of unicast address frames entered statically by the user during parameter assignment. On this page, you also define the static unicast filters. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 160
3. Click the "Create" button to create a new entry in the table. 4. Click the "Refresh" button. 5. Select the relevant port from the drop-down list. 6. Click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The port accepts only static MAC addresses that were created previously either manually or with the "Start Learning" function and the "Stop Learning" function. To enter all connected nodes automatically, there is a function for automatic learning (see "Layer 2 > Unicast > Learning"). SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 162
1. In the "Setting" drop-down list, select the "enabled" entry. 2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The device now enters the addresses of connected devices until you stop the function. 2. Click the "Stop learning" button to stop the learning function. The button is once again replaced by the "Start Learning" button. The learned entries are stored. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Depending on the number of entries involved, deleting may take some time. 5.5.12.4 Unicast blocking Blocking forwarding of unknown unicast frames On this page, you can block the forwarding of unknown unicast frames for individual ports. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 165
1. In the "Setting" drop-down list, select the "enabled" entry. 2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The "Multicast" menu item, shows the multicast frames currently entered in the filter table and their destination ports that the user set in the parameters. Configuring multicast addresses SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 167
1. Select the required ID from the "VLAN ID" drop-down list. 2. Enter the MAC address in the "MAC Address" input box 3. Click the "Create" button. A new entry is generated in the table. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
IGMP Snooping Aging Time depending on the querier SCALANCE XB-200 as IGMP querier If a SCALANCE XB-200 is used as an IGMP querier, the query interval is 125 seconds. For the "IGMP Snooping Aging Time", set at least 250 seconds.
4. Click the "Set Values" button. 5.5.13.3 Multicast blocking Disabling the forwarding of unknown multicast frames On this page, you can block the forwarding of unknown multicast frames for individual ports. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 170
1. In the "Setting" drop-down list, select the "enabled" entry. 2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
The blocking of broadcast frames is disabled. – No Change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 172
1. In the "Setting" drop-down list, select the "enabled" entry. 2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Note If you disable RMON, these statistics are not deleted but retain their last status. ● Port Select the ports for which statistics will be displayed. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 174
Disabling RMON statistics for ports 1. Select the row you want to delete in the "Select" column. 2. Click the "Delete" button. No RMON statistics are displayed for the selected port. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
If you log on the first time or log on after a "Restore Factory Defaults and Restart", you will be prompted to change the password. Note Changing the password in Trial mode Even if you change the password in Trial mode, this change is saved immediately. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
RADIUS server. The local users have priority. Note The user is first searched for in the local database. If the user does not exist there or the password does not match, a RADIUS query is sent. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Here, enter the maximum number of query attempts before another configured RADIUS server is queried or the logon counts as having failed. As default, 3 is set. The range of values is 1 to 254. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 178
– Repetition of the secret access ID – Maximum number of transmission retries – Primary server 2. Click the "Set Values" button. Repeat this procedure for every server whose entry you want to modify. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
5.6.2.3 802.1x authenticator Enabling authentication for individual ports By selecting the appropriate options, you specify whether or not network access protection according to IEEE 802.1x is enabled on this port. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 180
Enable this option if you want reauthentication of an already authenticated end device to be repeated cyclically. ● 802.1x Auth. Status Shows the status of the authentication of the port: – Unauthorized – Authorized SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
A bad configuration on the "Management Access Control List" page can result in you being unable to access the device. You should therefore configure an access rule that allows access to the management before you enable the function. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 182
Specify whether the station (or the IP address) can access the device using the HTTP protocol. ● HTTPS Specify whether the station (or the IP address) can access the device using the HTTPS protocol. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 183
1. Select the check box in the row to be deleted. 2. Repeat this procedure for every entry you want to delete. 3. Click the "Delete" button. The rules are deleted and the page is updated. SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 184
Configuring with Web Based Management 5.6 The "Security" menu SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Troubleshooting/FAQ Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows Using TFTP, you can supply a device with new firmware even when it cannot be reached using WBM or CLI.
Page 186
Troubleshooting/FAQ 6.1 Downloading new firmware using TFTP without WBM and CLI SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 189
Time of day Manual setting, 101 SIMATIC Time Client, 107 SNTP (Simple Network Time Protocol), 102 System time, 100 Time zone, 104 Time-of-day synchronization, 102 UTC time, 104 Time setting, 70 Undersize, 64 SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...
Page 190
Index SCALANCE XB-200 Web Based Management Configuration Manual, 04/2015, C79000-G8976-C360-02...