VERSAFLOW MAG 1000 VERSAFLOW MAG 1000 VERSAFLOW MAG 1000 VERSAFLOW MAG 1000 Quick Start Quick Start Quick Start Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter.
SAFETY INSTRUCTIONS VERSAFLOW MAG 1000 Warnings and symbols used DANGER! This information refers to the immediate danger when working with electricity. DANGER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operator's plant.
Page 5
SAFETY INSTRUCTIONS VERSAFLOW MAG 1000 34-VF-25-54 iss.3 GLO July 14 US www.honeywellprocess.com...
INSTALLATION VERSAFLOW MAG 1000 2.1 Scope of delivery INFORMATION! Do a check of the packing list to make sure that you have all the elements given in the order. INFORMATION! Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer.
INSTALLATION VERSAFLOW MAG 1000 2.2 Device description Your measuring device is supplied ready for operation. The factory settings for the operating data have been made in accordance with your order specifications. The following versions are available: • Compact version (the signal converter is mounted directly on the measuring sensor) •...
INSTALLATION VERSAFLOW MAG 1000 2.3 Nameplate INFORMATION! Check the device nameplate to ensure that the device is delivered according to your order. Additional information (a.o correct supply voltage), can be found in the documentation of the signal converter. Figure 2-3: Example of nameplate...
INSTALLATION VERSAFLOW MAG 1000 2.4 Storage • Store the device in a dry and dust-free location. • Avoid lasting direct exposure to the sun. • Store the device in its original packaging. • Storage temperature: -50 ...+70°C / -58...+158°F 2.5 Transport Signal converter •...
INSTALLATION VERSAFLOW MAG 1000 2.7 General requirements INFORMATION! The following precautions must be taken to ensure reliable installation. Make sure that there is adequate space to the sides. • Protect the signal converter from direct sunlight and install a sun shade if necessary.
INSTALLATION VERSAFLOW MAG 1000 2.8 Installation conditions 2.8.1 Inlet and outlet Use straight inlet and outlet pipe sections to prevent flow distortion or swirl, caused by bends and T- sections. Figure 2-7: Recommended inlet and outlet section 1 Refer to chapter "Bends in 2 or 3 dimensions"...
INSTALLATION VERSAFLOW MAG 1000 2.8.4 Bends Figure 2-10: Installation in bending pipes Figure 2-11: Installation in bending pipes CAUTION! Avoid draining or partial filling of the flow sensor 2.8.5 Open feed or discharge Figure 2-12: Installation in front of an open discharge www.honeywellprocess.com...
INSTALLATION VERSAFLOW MAG 1000 2.8.6 Flange deviation CAUTION! Max. permissible deviation of pipe flange faces: ≤ 0.5 mm / 0.02" Figure 2-13: Flange deviation 2.8.7 Pump Figure 2-14: Installation behind a pump 2.8.8 Control valve Figure 2-15: Installation in front of a control valve 34-VF-25-54 iss.3 GLO July 14 US...
INSTALLATION VERSAFLOW MAG 1000 2.8.9 Air venting and vacuum forces Figure 2-16: Air venting 1 ≥ 5 m 2 Air ventilation point Figure 2-17: Vacuum 1 ≥ 5 m www.honeywellprocess.com 34-VF-25-54 iss.3 GLO July 14 US...
INSTALLATION VERSAFLOW MAG 1000 2.8.10 Mounting position Figure 2-18: Mounting position 2.9 Mounting 2.9.1 Torques and pressures The maximum pressure and torques values for the flowmeter are theoretical and calculated for optimum conditions and use with carbon steel flanges. Figure 2-19: Tightening of bolts Tightening of bolts •...
Page 16
INSTALLATION VERSAFLOW MAG 1000 Nominal DN Pressure Bolts Max. torque [Nm] [mm] rating Polypropylene Hard rubber PN 40 4 x M 12 PN 40 4 x M 16 PN 40 4 x M 16 PN 40 4 x M 16...
Page 17
INSTALLATION VERSAFLOW MAG 1000 Nominal size Flange class Bolts Max. torque [Nm] [inch] [lb] Polypropylene Hardrubber 4 x 1/2" 1 1/2 4 x 1/2" 4 x 5/8" 4 x 5/8" 8 x 5/8" 8 x 3/4" 8 x 3/4" 12 x 7/8"...
INSTALLATION VERSAFLOW MAG 1000 2.10 Temperatures CAUTION! Protect the device from direct sunlight. Temperature range Process [°C] Ambient [°C] Process [°F] Ambient [°F] min. max. min. max. min. max. min. max. Hard rubber Hard rubber Hard rubber Hard rubber Separate flow sensor...
Page 19
INSTALLATION VERSAFLOW MAG 1000 34-VF-25-54 iss.3 GLO July 14 US www.honeywellprocess.com...
ELECTRICAL CONNECTIONS VERSAFLOW MAG 1000 3.1 Safety instructions DANGER! All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! DANGER! Observe the national regulations for electrical installations! DANGER! For devices used in hazardous areas, additional safety notes apply;...
Page 21
ELECTRICAL CONNECTIONS VERSAFLOW MAG 1000 Figure 3-2: Different types of grounding rings 1 Grounding ring number 1 2 Grounding ring number 2 3 Grounding ring number 3 Grounding ring number 1: • 3 mm / 0.1" thick (tantalum: 0.5 mm / 0.02") Grounding ring number 2: •...
ELECTRICAL CONNECTIONS VERSAFLOW MAG 1000 3.3 Virtual reference for TWM 9000 (C, W and F version) The virtual reference option on the TWM 9000 flow converter provides complete isolation of the measurement circuit. Benefits of virtual reference: • Grounding rings or grounding electrodes can be omitted.
Page 23
ELECTRICAL CONNECTIONS VERSAFLOW MAG 1000 34-VF-25-54 iss.3 GLO July 14 US www.honeywellprocess.com...
TECHNICAL DATA VERSAFLOW MAG 1000 4.1 Dimensions and weights Remote version Remote version a = 88 mm / 3.5" Remote version Remote version b = 139 mm / 5.5" c = 106 mm / 4.2" Total height = H + a...
Page 25
TECHNICAL DATA VERSAFLOW MAG 1000 INFORMATION! All data given in the following tables are based on standard versions of the flow sensor only. • Especially for smaller nominal sizes of the flow sensor, the signal converter can be bigger •...
TECHNICAL DATA VERSAFLOW MAG 1000 4.2 Vacuum load Diameter Vacuum load in mbar abs. at a process temperature of [mm] 20ºC 40ºC 60ºC 80ºC Hard rubber Hard rubber Hard rubber Hard rubber DN200...300 DN350...1000 DN1200...3000 Polypropylene Polypropylene Polypropylene Polypropylene DN25...150...
Page 28
TECHNICAL DATA VERSAFLOW MAG 1000 www.honeywellprocess.com 34-VF-25-54 iss.3 GLO July 14 US...