System Configuration Guide Liquid cooling model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. October 23, 2015 Revision 6.0 NEC Corporation...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Technical Specification Key Features Ultra compact form of 93mm in width, 13 liters in volume Up to 32 GB of high speed DDR3-1600 memory Full manageability by integrated EXPRESSSCOPE Engine 3 ...
Page 4
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating environment. For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html Revision 6.0 – October 23, 2015...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model External Views Front View Legend Power Button USB 2.0 Connector Power LED Optical Disk Drive Hard Drive Activity LED 3.5-inch Media Bay System Status LED Drive Bay Cover Key USB 3.0 Connector...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Dimensions (mm) Standard Bezel Tower Orientation Desktop Orientation Revision 6.0 – October 23, 2015 NEC Corporation...
Page 7
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Dust Proof Bezel Tower Orientation Desktop Orientation Revision 6.0 – October 23, 2015 NEC Corporation...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/T110g-S N8100-2196F no Processor, no RAM, no Drive Cage, no HDD, no Optical Drive Including: 250 Watt non-hot plug power supply, EXPRESSBUILDER DVD...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4 Internal Hard Disk Drives RAID Configuration Refer to the section in accordance with your disk form factor and RAID configuration 4.1.1 2.5-inch Drive Up to four Drives Available Interface...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.1.2 3.5-inch Drive Up to two 3.5-inch Drives Available Interface SATA Non-RAID Refer to 4.3.1 Embedded SATA SATA Refer to 4.3.2 RAID Controller RAID 0/1 SATA Optional RAID 0 MB Cache Refer to 4.3.3...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 2.5-inch Drive Configuration 4.2.1 Up to four Drives with Embedded SATA Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller (Standard) 4x 6Gb/s SATA Cable Internal SATA Cable...
Page 14
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.3 Up to four Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (0MB, RAID 0/1) N8103-171 Required LSI MegaRAID SAS 9240-8i RAID0/1/10, no cache memory, Int.
Page 15
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.4 Up to four Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (512MB, RAID 0/1) N8103-172 Required LSI MegaRAID SAS 9272-8i RAID0/1/10, 512 MB, Int.
Page 16
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.5 Up to four Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (512MB, RAID 0/1/5/6) N8103-173 Required LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512 MB, Int.
Page 17
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.6 Up to four Drives with RAID 5 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller RAID Controller (1GB, RAID0/1/5/6) N8103-174 Required LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 1 GB, Int.
Page 18
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.7 Up to four Drives with RAID 5 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller RAID Controller (1GB, RAID 0/1/5/6) N8103-168 Required LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int.
Page 19
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.8 Up to six Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (0MB, RAID 0/1) N8103-171 Required LSI MegaRAID SAS 9240-8i RAID0/1/10, no cache memory, Int.
Page 20
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.9 Up to six Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (512MB, RAID 0/1) N8103-172 Required LSI MegaRAID SAS 9272-8i RAID0/1/10, 512 MB, Int.
Page 21
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.10 Up to six Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (512MB, RAID 0/1) N8103-173 Required LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512 MB, Int.
Page 22
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.11 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller RAID Controller (1GB, RAID0/1/5/6) N8103-174 Required LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 1 GB, Int.
Page 23
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.2.12 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller RAID Controller (1GB, RAID 0/1/5/6) N8103-168 Required LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 3.5-inch Drive Configuration 4.3.1 Up to two Drives with Embedded SATA Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller (Standard) 4x 6Gb/s SATA Cable Internal SAS/SATA Cable...
Page 25
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.3.3 Up to two Drives with RAID 0/1 Controller with 0 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (0MB, RAID 0/1) N8103-171 Required LSI MegaRAID SAS 9240-8i RAID0/1/10, no cache memory, Int.
Page 26
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 4.3.5 3.5-inch and 2.5-inch Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller RAID Controller (512MB, RAID 0/1) N8103-172 Required LSI MegaRAID SAS 9272-8i RAID0/1/10, 512 MB, Int.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Hot plug insertion/removal is not supported on the drive configuration. All hard drives within a RAID array should be of the same form factor, capacity and rotation speed.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012 or later and Linux support teaming with bonding function supported by OS.
The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model 9 Add-on Components Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard With Remote KVM and Media...
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model OS Support Matrix for PCI Cards and Embedded Controllers Part Number Product Name Embedded SATA non-RAID Controller Embedded SATA RAID Controller Embedded 1GbE NIC - ...
All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
– SYSTEM CONFIGRATION GUIDE NEC Express5800/T110g-S / Liquid cooling model Revision History Revision Date Description New products added: October 23, 2015 External DVD Super MULTI Drive / N8160-97F USB Extension Cable / K410-351(00) RDX Cartridge (2TB) / N8153-09 Discontinued product deleted:...